R01UH0092EJ0110 Rev.1.10
Page 443 of 807
Jul 31, 2012
M16C/64C Group
22. Remote Control Signal Receiver
Table 22.20 Registers and Setting Values in Input Capture Mode (Simultaneous Count Operation) (1/2)
Register
Bit
Function
PMC0
PMC1
PMCiCON0
EN
Set to 1. (Refer to 22.3.5.1 “Setting
Procedure”).
Set to 1. (Refer to 22.3.5.1 “Setting
Procedure”).
SINV
Select input signal polarity.
Select input signal polarity.
FIL
Select filter enabled/disabled.
Select filter enabled/disabled.
EHOLD
Set to 0.
-
HDEN
Set to 0.
Set to 0.
SDEN
Set to 0.
-
DRINT0
Set to 00b.
-
DRINT1
PMCiCON1
TYP0
Select measuring object.
Select measuring object.
TYP1
CSS
Set to 1.
-
EXSDEN
Set to 0.
-
EXHDEN
Set to 0.
-
PMCiCON2
ENFLG
Flag indicating PMCi
operated/stopped.
Not used.
INFLG
Input signal flag
Input signal flag
CEFLG
Counter overflow flag
Counter overflow flag
CEINT
Set to 1 when using counter
overflow interrupt.
Set to 1 when using counter
overflow interrupt.
PSEL0
Set to 01b.
Set to 10b.
PSEL1
PMCiCON3
CRE
Set to 1.
Set to 1.
CFR
Set to 1.
Set to 1.
CST
Set to 1.
Set to 1.
PD
Set to 1.
Set to 1.
CSRC0
Set to 00b
Select clock source.
CSRC1
CDIV0
Set to 00b.
Select count source divisor.
CDIV1
PMCiSTS
CPFLG
Not used (read as undefined value)
-
REFLG
Not used (read as undefined value) Not used (read as undefined value)
DRFLG
Not used (read as undefined value) Not used (read as undefined value)
BFULFLG
Not used (read as undefined value)
-
PTHDFLG
Not used (read as undefined value) Not used (read as undefined value)
PTD0FLG
Not used (read as undefined value) Not used (read as undefined value)
PTD1FLG
Not used (read as undefined value) Not used (read as undefined value)
SDFLG
Not used (read as undefined value)
-
i = 0, 1
-: Unimplemented bits in PMC1
Note:
1.
This table does not describe a procedure.
Содержание M16C Series