7542 Group
Rev.3.02 Oct 31, 2006 Page 102 of 134
REJ03B0006-0302
Table 24 Timing requirements (3) (General purpose)
(Mask ROM version: V
CC
= 2.2 to 5.5 V, V
SS
= 0 V, Ta = –20 to 85 °C, unless otherwise noted) (This is only for the mask ROM version.)
Min.
Typ.
Max.
Symbol
Parameter
Limits
Unit
Reset input “L” pulse width
External clock input cycle time
External clock input “H” pulse width
External clock input “L” pulse width
CNTR
0
input cycle time
CNTR
0
, INT
0
, INT
1
, CAP
0
, CAP
1
input “H” pulse width (Note 1)
CNTR
0
, INT
0
, INT
1
, CAP
0
, CAP
1
input “L” pulse width (Note 1)
Serial I/O1, serial I/O2 clock input cycle time (Note 2)
Serial I/O1, serial I/O2 clock input “H” pulse width (Note 2)
Serial I/O1, serial I/O2 clock input “L” pulse width (Note 2)
Serial I/O1, serial I/O2 input set up time
Serial I/O1, serial I/O2 input hold time
t
W
(RESET)
t
C
(X
IN
)
t
WH
(X
IN
)
t
WL
(X
IN
)
t
C
(CNTR
0
)
t
WH
(CNTR
0
)
t
WL
(CNTR
0
)
t
C
(S
CLK1
)
t
WH
(S
CLK1
)
t
WL
(S
CLK1
)
t
su
(RxD
1
–S
CLK1
)
t
h
(S
CLK1
–RxD
1
)
2
500
200
200
1000
460
460
4000
1900
1900
800
400
µ
s
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
Notes 1: As for CAP
0
, CAP
1
, it is the value when noise filter is not used.
2: In this time, bit 6 of the serial I/O1 control register (address 001A
16
) is set to “1” (clock synchronous serial I/O is selected).
When bit 6 of the serial I/O1 control register is “0” (clock asynchronous serial I/O1 is selected), the rating values are divided by 4.
In this time, bit 6 of the serial I/O2 control register (address 0030
16
) is set to “1” (clock synchronous serial I/O is selected).