65
4.
Fill the leak oil line
5. Replace the double pump
6. Fit the leak oil line
7. Mount the pressure line
8. Preparation for tank filling: with filter pump with 10mμ element and integrated tank
installation return filter, type: RFM ON 210 BE 10 A0.1; Make HYDAC.
9. Fill the tank step by step and, depending on the level, screw the corresponding suction
line to the pump. In this way there is very little air in the suction hose. Check suction lines
for leaks
10. Filling level slightly higher than the desired level, since the level will still fall due to the
hydraulic drive. If necessary, oil must be refilled.
11. Test run with low PTO speed.
Important: if a nagging noise should occur, immediately switch off the PTO and contact
the factory customer service immediately.