51/05
- 13 –
Parameter 77
Activation lock time closing time 2
0 – normal mode
1 – closing time mode
Parameter 78
Activation lock time closing time 3
0 – normal mode
1 – closing time mode
Example : The motion sensor Outside is locked from 6 p.m. until 8 a.m.
1. Start 1:
(P70)
= 06:00:00 p.m.
2. End 1:
(P71)
= 08:00:00 a.m.
3. Closing time mode:
P(76)
= 1
Parameter 80:
New safety check interval, internal counters are reset
Parameter 81:
Maintenance interval in months
Parameter 82:
Accumulator operation in case of power failure
0 – normal operation for approx. one hour at 50 cycles
1 – door OPENS in case of power failure and remains in this position until power returns
2 – all holding functions are deactivated; the door
always
closes immediately after an opening run
Parameter 83:
Pull and Go Func tion
0 – door can
not
be operated manually. The door is kept closed by motor operation and an acoustic
signal warn s the user in case of manual opening.
1 – door can be manually operated. The door is opened by motor operation. The CompletelyOpen1
function is carried out.
2 – door can be manually operated. The door is opened by motor operation. The PartlyOpen func-
tion is carried out.
3 – door can be manually operated. The door is opened by motor operation. The PermanentlyOpen
function is carried out..
4 – door can be manually operated. The door opens automatically until the set opening width (pa-
rameter 15) is reached. The PermanentlyPartlyOpen function is carried out.
Parameter 84:
Safety elements:
0 – deactivated
1 – active
Parameter 85:
Number of safety elements:
1 – Operation with one safety element
2 – Operation with two safety elements
Parameter 86:
Self-monitoring function for safety element 1:
0 - deactivated
1 – active
Parameter 87:
Self-monitoring function for safety element 2:
0 – deactivated
1 – active
Parameter 88
Key lock time start – time when all operating elements are locked.
Parameter 89
Key lock time end – time when all operating elements are reactivated.
Example : The operating elements are locked from 4 p.m. until 6 a.m.
1. Start:
(P88)
= 04:00:00 p.m.
2. End:
(P89)
= 06:00:00 a.m.
Parameter 95
Enable program modules (5-digit);
1 – motion sensor
2 – safety elements
3 – interlocking function
4 – self-monitoring function for safety elements
5 – accumulator operation (emergeny power)
Содержание S 3000
Страница 1: ...OPERATING INSTRUCTIONS SLIDING DOOR DRIVING MECHANISM S 3000 V1 38EN 19 12 05 ...
Страница 16: ... 16 11 0 Terminal diagrams 11 1 Cable laying diagram ...
Страница 17: ...51 05 17 11 2 Terminal assignment ...
Страница 18: ... 18 12 0 Dimensions 12 1 Sectional drawing one wing drive ...
Страница 19: ...51 05 19 12 2 Sectional drawing telescopic and two wing drive ...