51/05
- 15 –
10.2 List
Start command: sys
Page 1
Sliding door driving mechanism S 3000
L
EType:12345
Reisinger GmbH (c) 2005
V 1.380
S/N : 0401001
MType:STANDARD
--------------------------------------------------------------------------------
1. Time PARTLY OPEN
1 [ s]
21. Speed OPEN
144 [--]
2. Time COMPLETELY OPEN 1
12 [ s]
22. Speed CLOSE
90 [--]
3. Time MS I
1 [ s]
23. Speed RUNNING-IN
36 [--]
4. Time MS O
1 [ s]
24. Speed TEACH-IN
48 [--]
5. Time REV
5 [ s]
25.
--
6. Time COMPLETELY OPEN 2
12 [ s]
26.
--
7. Electrical lock locking time
0 [ s]
27.
--
8. Automatic start
1 [--]
28.
--
9. Password
0
29.
--
10. Width PERMANENTLY OPEN
1123 [mm]
30.
--
11. Width PARTLY OPEN
800 [mm]
31. REV sensitivity OPEN
100 [--]
12. Width COMPLETELY OPEN 1
1123 [mm]
32. REV sensitivity CLOSE
100 [ --]
13. Width MS I
1123 [mm]
33. Acceleration slope
400 [--]
14. Width MS O
1123 [mm]
34. Braking slope OPEN
4 [ --]
15
Width PERMANENTLY PARTLY OPEN500[mm]
35
Braking slope CLOSE
4 [--]
16. Width COMPLETELY OPEN 2
1123 [mm]
36. REV cycles
5 [--]
17. Running-in zone OPEN
70 [mm]
37.
--
18. Running-in zone CLOSE
70 [mm]
38.
--
19. Safe distance
10 [mm]
39.
--
20. Stop CLOSE
10 [mm]
40. Language
1 [--]
0. Quit
98. P41..P80
97. P81..P951.
Page 2
Sliding door driving mechanism S 3000
L
EType: 12345
Reisinger GmbH (c) 2005
V 1.380
S/N : 0401001
MType: STANDARD
41. Date
14.03.05
61. Program selector
0 [--]
42. Time
09:46:47
62. Works setting
43. Summertime
0 [--]
63. Lighting frame
0 [--]
44.
--
64. Relay K2
1 [--]
45.
--
65. Acoustic signals
1 [--]
46.
--
66. Autom. holding open
0 [--]
47.
--
67.
--
48.
--
68.
--
49.
--
69.
--
50. Teach-in run
70. Lock time 1 Start Closing time
00:00:00
51. Special function
0 [--]
71. Lock time 1 End
Closing time
00:00:00
52. Teach-in run without speed test
72. Lock time 2 Start Closing time
00:00:0 0
53. Summer/winter mode
0 [--]
73. Lock time 2 End
Closing time
00:00:00
54. Opening width su/wi
80 [ %]
74. Lock time 3 Start Closing time
00:00:00
55. Closing time
0 [--]
75. Lock time 3 End
Closing time
00:00:00
56.
--
0 [--]
76. Lock time 1 Check
0 [--]
57. Electrical lock
0 [--]
77. Lock time 2 Check
0 [--]
58. Interlock K1 NO/NC
0 [--]
78. Lock time 3 Check
0 [--]
59. Auto CLOSE after REV
1 [--]
79.
--
60. Status display
80. Safety check
04.03.06
0. Quit
97. P81..P95
99. P01..P40
Page 3
Sliding door driving mechanism S 3000
L
EType: 12345
Reisinger GmbH (c) 2005
V 1.380
S/N : 0401001
MType: STANDARD
81. Safety interval
12 [mo]
82. Accumulator check
0 [--]
83. Pull and Go
1 [--]
84. Safety elements
0 [--]
85. Number of safety elements
1 [--]
86. Safety element 1 self -check0 [ --]
87. Safety element 2 self-check0 [--]
88. Key lock time Start
00:00:00
89. Key lock time End
00:00:00
95. Enable modules
0. Quit
99. P01..P40
98. P41..P80
Содержание S 3000
Страница 1: ...OPERATING INSTRUCTIONS SLIDING DOOR DRIVING MECHANISM S 3000 V1 38EN 19 12 05 ...
Страница 16: ... 16 11 0 Terminal diagrams 11 1 Cable laying diagram ...
Страница 17: ...51 05 17 11 2 Terminal assignment ...
Страница 18: ... 18 12 0 Dimensions 12 1 Sectional drawing one wing drive ...
Страница 19: ...51 05 19 12 2 Sectional drawing telescopic and two wing drive ...