12 –
Parameter 51:
Special functions: special input SI
0 – no function
1 – input (NO contact) SI activated – emergency opening in case of interlocking; door
OPENS
and
remains in this position, until SI is deactivated. This opening of the door is indicated by an
acoustic signal.
2 – input (NO contact) SI activated – opening in case of key lock time being active (P88 / P89)
3 – input (NO contact) SI activated – all current functions are interrupted and the door closes
4 – input (NC contact) SI activated – interlocking is deactivated.
PERMANENTLY OPEN
function
will change to partial opening
5 – input (NC contact) SI activated – Pull and go is deactivated; all current functions are interrupted
6 – input (NO contact) SI activated – door opens and remains in this position, until SI is deactivated
Parameter 52:
Teach-in run is started without automatic speed ajustment
Parameter 53:
Summer mode / winter mode
0 – Summer mode, total opening width
1 – Winter mode, reduced opening width at xx% (P54).
Parameter 54:
Opening width for winter mode in %
Parameter 55:
Closing time
0 – normal mode
1 – closing time mode, motion sensor Outside is deact ivated
Parameter 57:
Automatic electrical lock
0 – deactivated
1 – active
Parameter 58:
Interlock K1 as NO contact (0) or NC contact (1). K1 is activated at each opening of the door.
Parameter 59:
1 – after reversing door remains in open position until time (parameter 5) has elapsed
0 – after reversing door remains in open position until a key is pressed
Parameter 60:
Status display
Parameter 61:
Program selector
0 – deactivated
1 – active
Parameter 62:
All parameters are reset back to works settings according to parameter list; after reset
carry out
teach-in run!
Parameter 63
Lighting effect display frame
0 – deactivated
1 – activated
Parameter 64
Fault and maintenance message via relay K2
1 – relay K2 as NO/NC contact opens/closes in case of a fault message or if maintenance is due
0 – deactivated
Parameter 65:
Acoustic signal
0 – deactivated
1 – active
Parameter 66:
Power-operated holding in OPEN and CLOSE limit position
0 – deactivated
1 – active
Parameter 70
Lock time closing time 1 :
start
(Motion sensor Outside is locked)
Parameter 71
Lock time closing time 1 :
end
(Motion sensor Outside is activated)
Parameter 72
Lock time closing time 2 :
start
(Motion sensor Outside is locked)
Parameter 73
Lock time closing time 2 :
end
(Motion sensor Outside is activated)
Parameter 74
Lock time closing time 3 :
start
(Motion sensor Outside is locked)
Par ameter 75
Lock time closing time 3
end
(Motion sensor Outside is activated)
Parameter 76
Activation lock time closing time 1
0 – normal mode
1 – closing time mode
Содержание S 3000
Страница 1: ...OPERATING INSTRUCTIONS SLIDING DOOR DRIVING MECHANISM S 3000 V1 38EN 19 12 05 ...
Страница 16: ... 16 11 0 Terminal diagrams 11 1 Cable laying diagram ...
Страница 17: ...51 05 17 11 2 Terminal assignment ...
Страница 18: ... 18 12 0 Dimensions 12 1 Sectional drawing one wing drive ...
Страница 19: ...51 05 19 12 2 Sectional drawing telescopic and two wing drive ...