background image

-

4 –

2.5 Terminal

(optional)

>Terminal display in automatic mode<

The terminal consists of an LCD display with 16 x 2
characters, four status LEDs and a keyboard with four
keys.

2.5.1 Basic function

There are three basic terminal functions at the user’s
disposal:

1.

Status display, all messages are displayed in
plain text. LEDs offer additional informa tion.

2.

Parameter input

3.

Program Selector (PS)

2.5.2 Operating states

The display and the four coloured LEDs show the actual
o perating state.

Green LED >permanent< : ready for operation

Blue LED >blinking<

: selecting mode PS

Blue LED >permanent<

: PS active

Yellow LED >blinking<

: parameter input mode

Yellow LED >permanent<: safety check due

Red LED >flashing<

: password protection active

Red LED >permanent<

: fatal error

2.5.3 Key function

<E>

Acceptance

of

the

selected

parame-

ters/functions.

<P>

Three functions can be activated:

1. Change-over from main level to parameter

level and vice versa.

2. Abort at parameter or PS level

3. Position change in password or date/time

input

<+>

and

<

>

have two functions:

1. Selection of the parameter number or the

parameter value

2. Selection of the PS function

2.5.4 Parameter settings

The parameters are preset at works according to your
requirements and to the relevant standards.

Parameter modifications must only be carried out

by authorised staff. Improper modifications of the p a-
rameter values will exclude any liability of the manufac-
turer for damages resulting therefrom.

Example:

Changing

of

the

open

time

>COMPLETELYOPEN 1<

>Terminal display in automatic mode PS<

Press

<P>

:

>Terminal display parameter input<

Use the

<+>

or

<

>

key to select the desired pa-

rameter.

You will find the parameter list in chapter 9.1.

By means of parameter 62 all parameters are

set back to the works setting.

Содержание S 3000

Страница 1: ...OPERATING INSTRUCTIONS SLIDING DOOR DRIVING MECHANISM S 3000 V1 38EN 19 12 05 ...

Страница 2: ...th terminal plug in terminal 50 53 6 5 2 2 with notebook plug in terminal 1 3 6 5 2 3 with PARTLYOPEN key plug in terminal 6 7 6 5 3 Fault clearance during putting into operation procedure 7 6 0 Features 7 6 1 Standard feature 7 6 2 Optional features 7 6 3 Safety features 7 7 0 Maintenance Safety check 8 8 0 Fault clearance 8 8 1 Error code 8 9 0 Parameters 9 9 1 Parameter list Terminal RS232 9 9 ...

Страница 3: ...t users of a door system The appropriate operating instructions serve as an aid 2 0 Product description 2 1 Designation Model DIN left or DIN right right left handed opening S 3000 one wing S 3000 two wing S 3000 telescopic 2 2 Design Standard up to 150 kg Heavy SK up to 250 kg Hermetic HE up to 150 kg 2 3 Driving mechanism Sliding rail and trolley are made of anodized alu minium profile The troll...

Страница 4: ... Acceptance of the selected parame ters functions P Three functions can be activated 1 Change over from main level to parameter level and vice versa 2 Abort at parameter or PS level 3 Position change in password or date time input and have two functions 1 Selection of the parameter number or the parameter value 2 Selection of the PS function 2 5 4 Parameter settings The parameters are preset at wo...

Страница 5: ...r value here 12s Display after pressing E key 2 5 5 Programm selector The following modes are available 1 Permanently open 2 Closing time 3 Winter mode 4 Electrical lock 5 Winter mode and closing time 6 Manual mode Example PS mode Closing time Standard display PS inactive Parameter 61 select 1 Display PS mode Use the or key to select the desired mode here Closing time Use the E key to ac cept this...

Страница 6: ...f the manufacturer for damages resulting therefrom 4 0 Assembly Only authorized technical staff is allowed to carry out the assembly of the driving mechanism The compulsory in struction on our premises is the basis for proper assem bly The instruction material includes all instructions re quired for assembly 5 0 Putting into operation The setting up of the driving mechanism for the putting into op...

Страница 7: ...external door is possible As soon as one door is open opened the locking moni toring device will prevent another door belonging to the interlock from being opened A signalling optical acoustic of the interlock state via CHK1 terminal 59 60 unlocked and CHK2 terminal 57 58 interlocked is possible only with module 4 being inactive The max total out put current of the switchable outputs CHK1 2 is 0 4...

Страница 8: ...cessary to unplug the mains plug thus interrupting the power supply 8 0 Fault clearance The sliding door driving mechanism continuously carries out self diagnoses and adjusts itself automatically In case of values beyond the set value range error messages are displayed The error is indicated via the termi nal in plain text and as a colour code of the LEDs installed at the driving unit at the same ...

Страница 9: ...1 end closing time Lock time 1 end closing time Format hh mm ss 17 Running in OPEN Running in zone OPEN 50 200 mm 70 72 Lock time 2 start closing time Lock time 2 start closing time Format hh mm ss 18 Running in CLOSE Running in zone CLOSE 50 200 mm 70 73 Lock time 2 end closing time Lock time 2 end closing time Format hh mm ss 19 Safe distance Safe distance 0 30 mm 10 74 Lock time 3 start closing...

Страница 10: ...partial opening Parameter 2 Open time in seconds for complete opening 1 Parameter 3 Open time in seconds for motion sensor Inside Parameter 4 Open time in seconds for motion sensor Outside Parameter 5 Open time in seconds after reversing Parameter 6 Open time in seconds for complete opening 2 Parameter 7 Delay time until activation of electrical lock Parameter 8 Automatic start 0 door starts after...

Страница 11: ...increased risk of injury Parameter 33 The acceleration slope ensures a smooth starting of the door without any jerks The works setting of the parameter value is 400 It should only be modified with care Smaller values signify a steeper slope i e the door is accelerated faster greater values signify a more gentle slope i e the door is accelerated less fast Attention This parameter affects the servic...

Страница 12: ...K1 as NO contact 0 or NC contact 1 K1 is activated at each opening of the door Parameter 59 1 after reversing door remains in open position until time parameter 5 has elapsed 0 after reversing door remains in open position until a key is pressed Parameter 60 Status display Parameter 61 Program selector 0 deactivated 1 active Parameter 62 All parameters are reset back to works settings according to...

Страница 13: ...unction is carried out 2 door can be manually operated The door is opened by motor operation The PartlyOpen func tion is carried out 3 door can be manually operated The door is opened by motor operation The PermanentlyOpen function is carried out 4 door can be manually operated The door opens automatically until the set opening width pa rameter 15 is reached The PermanentlyPartlyOpen function is c...

Страница 14: ...ms Accessories Windows 98 ME XP 10 1 Configuration Before the first start the following link settings must be entered Enter link name and select link Select link Enter linking features Select font and size Other settings Complete data link Plug in data cable terminal 1 3 and connect it to the PC 9pole D Sub at the serial interface RS 232 Important The sliding door must be closed during data commun...

Страница 15: ... V 1 380 S N 0401001 MType STANDARD 41 Date 14 03 05 61 Program selector 0 42 Time 09 46 47 62 Works setting 43 Summertime 0 63 Lighting frame 0 44 64 Relay K2 1 45 65 Acoustic signals 1 46 66 Autom holding open 0 47 67 48 68 49 69 50 Teach in run 70 Lock time 1 Start Closing time 00 00 00 51 Special function 0 71 Lock time 1 End Closing time 00 00 00 52 Teach in run without speed test 72 Lock tim...

Страница 16: ... 16 11 0 Terminal diagrams 11 1 Cable laying diagram ...

Страница 17: ...51 05 17 11 2 Terminal assignment ...

Страница 18: ... 18 12 0 Dimensions 12 1 Sectional drawing one wing drive ...

Страница 19: ...51 05 19 12 2 Sectional drawing telescopic and two wing drive ...

Страница 20: ... 20 Reisinger GmbH Unterschöllenbacher Straße 1 90562 Kalchreuth Tel 49 0 911 956 80 70 Fax 49 0 911 956 80 72 www reisinger de info reisinger de ...

Отзывы: