9.0 Parameters

9.1 Parameter list Terminal / RS232

P Designation

Terminal

Designation
RS232

min.

max.

Unit Works setting

P

Designati on
Terminal

Designation
RS232

min. max. W orks

setting

1

T ime PARTLY
OPEN

Time PARTLY
OPEN

0

200

s

1

51

Special function

Special function

0

6

0

2

Time COMPLETELY
OPEN 1

Time
COMPLETELY
OPEN 1

0

200

s

12

52

Teach-in run with-
out speed test

Teach- in run with-
out speed test

3

Time MS I

Time MS I

1

200

s

1

53

Summer/winter

Summer/winter
mode

0

1

0

4

Time MS O

Time MS O

1

200

s

1

54

Width su/wi

Opening width
su/wi

40

100

80

5

Time REV

Time REV

1

200

s

5

55

Closing time

Closing time

0

1

0

6

Time COMPLETELY
OPEN 2

Time
COMPLETELY
OPEN 2

1

200

s

12

57

Electrical lock

Electrical lock

0

1

0

7

Eletrical lock locking
time

Electrical lock
locking time

1

60

s

1

58

Intelrock K 1 S/I

Interlock1 NO/NC

0

1

0

8

Autom. start

Autom. start

0

1

1

59

Autom. CLOSE
REV

Autom. CLOSE af-
ter REV

0

1

1

9

Password

Password

00000

99999

0

61

PS

Program selectorr

0

1

0

10

Width
PERMANENTLY
OPEN

Width
PERMANENTLY
OPEN

200

3000

mm

door- dependent

62

Works setting

Works setting

11

Width PARTLY
OPEN

Width PARTLY
OPEN

200

3000

mm

door- dependent

63

Lighting frame

Lighting frame

0

1

0

12

Width
COMPLETELY
OPEN 1

Width
COMPLETELY
OPEN 1

200

3000

mm

door- dependent

64

Relay K2

Relay K2

0

1

1

13

Width MS I

Width MS I

200

3000

mm

door- dependent

65

Acoustic signals

Acoustic signals

0

1

1

14

Width MS O

Width MS O

200

3000

mm

door- dependent

66

Autom. holding
open

Autom. holding
open

0

1

0

15

Width
PERMANENTLY
PARTLY OPEN

Width
PERMANENTLY
PARTLY OPEN

200

3000

mm

door- dependent

70

Lock time 1 start
closing time

Lock time 1 start
closing time

Format
hh:mm:ss

16

Width
COMPLETELY
OPEN 2

Width
COMPLETELY
OPEN 2

200

3000

mm

door- dependent

71

Lock time 1 end
closing time

Lock time 1 end
closing time

Format
hh:mm:ss

17

Running-in OPEN

Running-in zone
OPEN

50

200

mm

70

72

Lock time 2 start
closing time

Lock time 2 start
closing time

Format
hh:mm:ss

18

Running-in CLOSE

Running-in zone
CLOSE

50

200

mm

70

73

Lock time 2 end
closing time

Lock time 2 end
closing time

Format
hh:mm:ss

19

Safe distance

Safe distance

0

30

mm

10

74

Lock time 3 start
closing time

Lock time 3 start
closing time

Format
hh:mm:ss

20

Stop CLOSE

Stop CLOSE

0

30

mm

10

75

Lock time 3 end
closing time

Lock time 3 end
closing time

Format
hh:mm:ss

21

Speed OPEN

Speed OPEN

20

255

calculated by
means of teach-
in run

76

Lock time 1 check

Lock time 1 check

0

1

0

22

Speed CLOSE

Speed CLOSE

20

255

calculated by
means of teach-
in run

77

Lock time 2 check

Lock timet 2 check 0

1

0

23

Speed RUNNING-IN

Speed
RUNNING- IN

20

100

calculated by
means of teach-
in run

78

Lock time 3 check

Lock time 3 check

0

1

0

24

Speed TEACH-IN

Speed TEACH-
IN

20

100

calculated by
means of teach-
in run

80

Safety check

Safety check

31

REV sensit. OPEN

REV sensitivty
OPEN

20

999

100

81

Safety inteval

Safety interval

3

12

12

32

REV sensit. CLOSE

REV sensitivity
CLOSE

20

999

100

82

Accumulator check Accumulator check 0

2

0

33

Acceleration slope

Acceleration slo-
pe

100

2000

400

83

Pull and Go

Pull and Go

0

4

1

34

Braking slope OPEN

Braking slope
OPEN

0

20

4

84

Safety elements

Safety elements

0

1

0

35

Braking slope CLO-
SE

Braking slope
CLOSE

0

20

4

85

Number of safety
elements

Number of safety
elements

1

2

1

36

REV cycles

REV cycles

1

99

5

86

Light barrier 1 self-
check

Light barrier 1 self-
check

0

1

0

40

Language

Language

1

2

1

87

Light barrier 2 self-
check

Light barrier 2 self-
check

0

1

0

41

Date

Date

Format
dd.mm.yy

88

Key lock time start Key lock time start

Format
hh:mm:ss

42

Time

Time

hh:mm:ss

89

Key lock time end

Key lock time end

Format
hh:mm:ss

43

Summertime

Summertime

0

1

date-dependent

95

Modules

Enable modules

50

Teach -in run

Teach- in run

Содержание S 3000

Страница 1: ...OPERATING INSTRUCTIONS SLIDING DOOR DRIVING MECHANISM S 3000 V1 38EN 19 12 05 ...

Страница 2: ...th terminal plug in terminal 50 53 6 5 2 2 with notebook plug in terminal 1 3 6 5 2 3 with PARTLYOPEN key plug in terminal 6 7 6 5 3 Fault clearance during putting into operation procedure 7 6 0 Features 7 6 1 Standard feature 7 6 2 Optional features 7 6 3 Safety features 7 7 0 Maintenance Safety check 8 8 0 Fault clearance 8 8 1 Error code 8 9 0 Parameters 9 9 1 Parameter list Terminal RS232 9 9 ...

Страница 3: ...t users of a door system The appropriate operating instructions serve as an aid 2 0 Product description 2 1 Designation Model DIN left or DIN right right left handed opening S 3000 one wing S 3000 two wing S 3000 telescopic 2 2 Design Standard up to 150 kg Heavy SK up to 250 kg Hermetic HE up to 150 kg 2 3 Driving mechanism Sliding rail and trolley are made of anodized alu minium profile The troll...

Страница 4: ... Acceptance of the selected parame ters functions P Three functions can be activated 1 Change over from main level to parameter level and vice versa 2 Abort at parameter or PS level 3 Position change in password or date time input and have two functions 1 Selection of the parameter number or the parameter value 2 Selection of the PS function 2 5 4 Parameter settings The parameters are preset at wo...

Страница 5: ...r value here 12s Display after pressing E key 2 5 5 Programm selector The following modes are available 1 Permanently open 2 Closing time 3 Winter mode 4 Electrical lock 5 Winter mode and closing time 6 Manual mode Example PS mode Closing time Standard display PS inactive Parameter 61 select 1 Display PS mode Use the or key to select the desired mode here Closing time Use the E key to ac cept this...

Страница 6: ...f the manufacturer for damages resulting therefrom 4 0 Assembly Only authorized technical staff is allowed to carry out the assembly of the driving mechanism The compulsory in struction on our premises is the basis for proper assem bly The instruction material includes all instructions re quired for assembly 5 0 Putting into operation The setting up of the driving mechanism for the putting into op...

Страница 7: ...external door is possible As soon as one door is open opened the locking moni toring device will prevent another door belonging to the interlock from being opened A signalling optical acoustic of the interlock state via CHK1 terminal 59 60 unlocked and CHK2 terminal 57 58 interlocked is possible only with module 4 being inactive The max total out put current of the switchable outputs CHK1 2 is 0 4...

Страница 8: ...cessary to unplug the mains plug thus interrupting the power supply 8 0 Fault clearance The sliding door driving mechanism continuously carries out self diagnoses and adjusts itself automatically In case of values beyond the set value range error messages are displayed The error is indicated via the termi nal in plain text and as a colour code of the LEDs installed at the driving unit at the same ...

Страница 9: ...1 end closing time Lock time 1 end closing time Format hh mm ss 17 Running in OPEN Running in zone OPEN 50 200 mm 70 72 Lock time 2 start closing time Lock time 2 start closing time Format hh mm ss 18 Running in CLOSE Running in zone CLOSE 50 200 mm 70 73 Lock time 2 end closing time Lock time 2 end closing time Format hh mm ss 19 Safe distance Safe distance 0 30 mm 10 74 Lock time 3 start closing...

Страница 10: ...partial opening Parameter 2 Open time in seconds for complete opening 1 Parameter 3 Open time in seconds for motion sensor Inside Parameter 4 Open time in seconds for motion sensor Outside Parameter 5 Open time in seconds after reversing Parameter 6 Open time in seconds for complete opening 2 Parameter 7 Delay time until activation of electrical lock Parameter 8 Automatic start 0 door starts after...

Страница 11: ...increased risk of injury Parameter 33 The acceleration slope ensures a smooth starting of the door without any jerks The works setting of the parameter value is 400 It should only be modified with care Smaller values signify a steeper slope i e the door is accelerated faster greater values signify a more gentle slope i e the door is accelerated less fast Attention This parameter affects the servic...

Страница 12: ...K1 as NO contact 0 or NC contact 1 K1 is activated at each opening of the door Parameter 59 1 after reversing door remains in open position until time parameter 5 has elapsed 0 after reversing door remains in open position until a key is pressed Parameter 60 Status display Parameter 61 Program selector 0 deactivated 1 active Parameter 62 All parameters are reset back to works settings according to...

Страница 13: ...unction is carried out 2 door can be manually operated The door is opened by motor operation The PartlyOpen func tion is carried out 3 door can be manually operated The door is opened by motor operation The PermanentlyOpen function is carried out 4 door can be manually operated The door opens automatically until the set opening width pa rameter 15 is reached The PermanentlyPartlyOpen function is c...

Страница 14: ...ms Accessories Windows 98 ME XP 10 1 Configuration Before the first start the following link settings must be entered Enter link name and select link Select link Enter linking features Select font and size Other settings Complete data link Plug in data cable terminal 1 3 and connect it to the PC 9pole D Sub at the serial interface RS 232 Important The sliding door must be closed during data commun...

Страница 15: ... V 1 380 S N 0401001 MType STANDARD 41 Date 14 03 05 61 Program selector 0 42 Time 09 46 47 62 Works setting 43 Summertime 0 63 Lighting frame 0 44 64 Relay K2 1 45 65 Acoustic signals 1 46 66 Autom holding open 0 47 67 48 68 49 69 50 Teach in run 70 Lock time 1 Start Closing time 00 00 00 51 Special function 0 71 Lock time 1 End Closing time 00 00 00 52 Teach in run without speed test 72 Lock tim...

Страница 16: ... 16 11 0 Terminal diagrams 11 1 Cable laying diagram ...

Страница 17: ...51 05 17 11 2 Terminal assignment ...

Страница 18: ... 18 12 0 Dimensions 12 1 Sectional drawing one wing drive ...

Страница 19: ...51 05 19 12 2 Sectional drawing telescopic and two wing drive ...

Страница 20: ... 20 Reisinger GmbH Unterschöllenbacher Straße 1 90562 Kalchreuth Tel 49 0 911 956 80 70 Fax 49 0 911 956 80 72 www reisinger de info reisinger de ...

Отзывы: