9
│
• remove roof tiles where the anchors shall be mounted
Pic. 7: Opening the room for anchor installation
• screw a roof anchor to a rafter and shift it
in the groove horizontally so that it does not
hinder the right tile positioning
• for 2 or more collectors place the anchors
always about their presumed middles
2.2.3 Installation with roof anchors for slate, shingle or metal roofs
• Simply lay the anchor onto the roof tiles in a place
where the roof is supported with a strong roo
fi
ng element
(a beam or another support) and
fi
x it with stainless-steel
bolts. Cover the anchors with sheet metal to prevent water
leakage or use another suitable method recommended by
the roo
fi
ng manufacturer.
Ø 6
6
228
78−98
Pic. 9: A roof anchor for slate, shingle or metal roof
• cut the counter batten used for
fi
xing the waterproo
fi
ng membrane and if necessary, use an underlay depending
on the desired anchor height
Pic. 8: A place for mounting a roof anchor on a rafter - detail
counter batten
rafter
roof battens
room for anchor mount
counter batten
rafter
roof
battens
waterproofing membrane