Safety valves are always included in pump stations. If no pump station is used in the installation, the solar
system shall be equipped with a 6 bar safety valve, resistant to high temperatures (usually up to 160 °C).
7 Pump
Station
The pump station shall be installed in accordance with the respective manual.
Regulus pump stations contain these principal components:
• circulation pump
• thermometer for return line, or also feed line if two-pipe station is used
• return line with a ball valve and a check valve
• integrated
fl
owmeter
• safety valve, pressure gauge and expansion vessel connection
•
fi
ll and drain valve
• thermal insulation
An example of a pump station is shown in Pic. 28.
1 - Assembly holes
2 - Pressure gauge
3 - Ball valve with a check valve and thermometer
4 - Ball valve and
fl
owmeter
5 - Fill valve
6 - Drain valve
7 - Air separator with manual discharge
(not included in FlowConB package)
Pic. 28: FlowConB pump station