Manual Corrigo E Ventilation, revision M
Chapter 2
About Corrigo E
8
Use the up and down arrows to move the cursor in the left edge of the display to the application you
wish to load. Press right arrow to choose the selected application and go to Language choice.
Ventilation
Choose language
English
Accept changes:No
Press OK to choose language. Use the up and down arrows to move between languages and press
OK to confirm your choice.
When another language than English is chosen, both English and the selected language will be
loaded.
To make the final confirmation of the created programs and language choices, change No to Yes
and confirm by pressing OK.
After a few seconds, the display will show a start display in English for the chosen application.
After another few seconds, the display text will change to the selected language, if another language
than English has been selected.
Regulator vent. sys
08:06:03 09:32
System:Stopped
Sp: 19.5 Act: 20.1°C
Ventilation application
The temperature controller is based on a supply air PI-controller for heating control with a pre-
programmed set of control modes. To this controller can be bound a number of different control
functions and analogue and digital input and output functions. The choice of which functions are to
be used is free, the only restriction is the physical number of inputs and outputs of the different
models. The maximum number of I/Os is 3*28 (a 2-port Corrigo with two expansion controllers).
The Corrigo is designed for DIN-rail mounting.
The program for an air handling unit contains, apart from other things, the following functions:
Different temperature control modes
Supply air temperature control, with or without outdoor temperature compensation
Room temperature control (cascade controller)
Extract air temperature control (cascade controller).
Seasonal switching between supply air temperature control and room/extract air temperature
control.
Extra, separate temperature control circuit for after-heaters etc.
With control of:
Heat exchanger (Liquid connected- , plate- or rotating) or mixing dampers.
Heating coil; Water with frost protection or electric.
Chiller water-heated or DX, up to 3 steps.
Circulation pumps heating, cooling, exchanger.
Fan control
1- or 2-speed supply air fans and extract air fans.
Frequency controlled supply and extract air fans with pressure or flow control, manual control or
external control from a VAV system. Pressure controlled supply air fan with slave connected extract
air fan (output dependent or flow dependent).