background image

4

ENGLISH

NOTE:

The locknut should be on the outside of the coverplate.

Step 4:

After securing both lights to the coverplate for wall mounting, or
to mount the fixture as packed in the eave mounting position, 
follow 

Wiring your fixture

instructions that follow.

Wiring your fixture

NOTE: This fixture should be mounted to a grounded junction box
(not included).
Step 1: Turn off the power at the main fuse/breaker box.
Step 2:

Install the junction box mounting bracket using 2 of the 6-32 or 
8-32 x 1/2” screws, depending upon the screw receptacles in
your junction box.

Step 3:

Position the gasket included on the coverplate and connect the
black wires from both fixtures to the black house supply wire and
the white wires from both fixtures to the white supply wire using
the wire nuts provided. Attach any ground wire coming from your
house to the copper ground wires from both fixtures using wire
nuts provided. If no
house ground wire is
available, attach both
copper ground wires
from the fixture to
the junction box if it
is metal and ground-
ed. If junction box is
not metal and no
house ground wire is
available, an alterna-
tive ground source
must be used for safe operation. (See N for wiring diagram.)

Step 4:

Position the coverplate over the junction box and insert the 1 1/2”
screw included through the center hole in the coverplate and
tighten into the junction box mounting bracket installed in Step
#2. Be sure no loose wires remain sticking out from underneath
the coverplate.

Step 5:

Apply silicone caulk around the edges of the coverplate to pro-
vide a watertight seal from rain and moisture.

Step 6:

Turn on power at main fuse/breaker box.

NOTE: This fixture

can be used with a dimmer switch to adjust light output.

To install a dimmer switch: Use a dimmer switch designed for
incandescent lighting that has a rating of 300 watts or higher.
Follow the installation instructions included with the dimmer
switch.

Keeping the halogen bulb in a dim mode for an

extended period of time may shorten the life of the bulb. To
achieve maximum bulb life, occasionally turn the switch to
full brightness for a few hours.

White house

power wire

House

ground

Lamp fixture

ground

Black house

power wire

White lamp

fixture wires

Black lamp

fixture wires

N

TMQ I. S. 325-0369  6/17/04  2:50 PM  Page 4

Содержание CTMQ150

Страница 1: ...Instruction Manual Manual de Instrucciones Directives TMQ150 CTMQ150 TMQ150W CTMQ150W ENGLISH ESPA OL FRAN AIS TMQ I S 325 0369 6 17 04 2 50 PM Page 1...

Страница 2: ...Fixture must be connected to a 120 Volt 60 Hz power source any other connection voids warranty Fixture should be mounted to a grounded junction box marked for use in wet locations Keep away from flam...

Страница 3: ...socket opposite socket Be sure each end of bulb is securely positioned against socket Step 4 Replace glass lens cover Insert and tighten the screws that secure the glass lens cover Assembling your fi...

Страница 4: ...ed If junction box is not metal and no house ground wire is available an alterna tive ground source must be used for safe operation See N for wiring diagram Step 4 Position the coverplate over the ju...

Страница 5: ...of two years from date of original purchase and agrees to repair or at the Company s option replace a defective product without charge for either replacement parts or labor during such time This does...

Страница 6: ...tten or verbal is authorized by the Company This warranty gives you specific legal rights and you may also have other rights which vary from state to state To obtain warranty service call the Company...

Страница 7: ...ara lugares h medos El portal mparas debe estar conectado a una fuente de energ a de 120 Voltios 60 Hz Cualquier otro tipo de conexi n anula la garant a El portal mparas debe conectarse a una caja de...

Страница 8: ...e protecci n NOTA Nunca toque la bombilla con las manos ya que el aceite de su piel puede acortar su duraci n Paso 3 Para instalar la bombilla col quela en el casquillo con muelle y empuje la bombilla...

Страница 9: ...xi n Paso 3 Posicione el gasket incluido en la cubierta y conecte los alam bres negros del luminario con los alambres negros de la casa y los blancos con los blancos de la casa usando las tuercas de a...

Страница 10: ...el foco coloca do a menos de 4 grados de la horizontal para ptima ejecuci n Ajuste el luminario verticalmente a la posici n deseada y apriete la tuer ca giratoria Mantenimiento del aparato CUIDADO Sie...

Страница 11: ...PUEDAN SURGIR DE CUALQUIER VIOLACION DE ESTA GARANTIA TODAS LA GARANTIAS IMPLICITAS SI EXISTE ALGUNA INCLUYENDO GARANTIAS IMPLICITAS DE COMERCIALIDAD Y USO PARA UN PROPOSITO EN PARTICULAR ESTAN LIMIT...

Страница 12: ...d nergie de 120 Volts 60 Hertz Tout autre branchement que celui ci annule la garantie Le dispositif doit tre mont une bo te de connexion reli e la terre dont l utilisation dans des endroits mouill s...

Страница 13: ...la douille ressort et pousser l ampoule vers la douille jusqu ce qu elle s abaisse Placer l autre bout de l ampoule dans la douille fixe c t oppos S assurer que chaque bout de l ampoule est bien plac...

Страница 14: ...d al imentation et ensuite les fils blancs des deux projecteurs aux fils blancs d alimentation l aide des crous fils inclus Raccorder tout fil de mise la terre provenant de votre maison aux fils de mi...

Страница 15: ...if Pour un rendement optimal les appareils comportant des lampes quartz halog nes doivent tre install s de telle sorte que l ampoule se situe en de de 4 degr s de l horizontal Ajuster l appareil verti...

Страница 16: ...RCHANDE ET DE CONVENANCE A UNE FIN PARTIC ULIERE SONT LIMITEES EN DUREE A LA DUREE DE CETTE GARANTIE EXPLICITE Certains tats ne permettant pas l exclusion ou la limitation des dommages int r ts access...

Отзывы: