background image

Liberty® LRI4E / Regency Horizon® HRI4E  

Gas Insert

Owners & 

Installation Manual

www.regency-fire.com

Horizon

®

 HRI4E

Liberty

®

 LRI4E

 

-  Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other 

appliance. 

- WHAT TO DO IF YOU SMELL GAS
 • 

Do not try to light any appliance.

 

•  Do not touch any electrical switch: do not use any phone in your building.

 

  Leave the building immediately.

 

•  Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's  

instructions.

 

• If you cannot reach your gas supplier, call the fire department.

 

 

 

- Installation and service must be performed by a qualified installer, service agency or the gas supplier.

     WARNING
FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly could result in serious
injury, death, or property damage. 

MODELS:  LRI4E-NG11  Natural Gas              LRI4E-LP11 Propane
                  HRI4E-NG11  Natural Gas              HRI4E-LP11  Propane

919-933c

           FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.  6988 Venture St., Delta, BC  Canada, V4G 1H4

03.28.19

Installer: Please complete the details on the back cover 
and leave this manual with the homeowner.
Homeowner:
 Please keep these instructions for future reference.

Tested by: 

Certified to/Certifié pour: CSA 2.17-2017
                                            ANSI Z21.88-2017
                                            CSA 2.33-2017

Содержание Liberty LRI4E series

Страница 1: ...t reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage MODELS LRI4E NG11 Natural Gas LRI4E LP11 Propane HRI4E NG11 Natural Gas HRI4E LP11 Propane 919 933c FPI FIREPLACE P...

Страница 2: ...pletely by extinguishing the pilot light in the event of a continuous full seven days of inactivity This only applies if the CPI continuous pilot switch is in the on position Each time the main burner shuts down manually or through the call from the thermostat the seven day timer starts again The seven day inactivity timer is controlled within the circuit board Therefore if in CPI mode and when th...

Страница 3: ...4E 56 Glass Burner Removal 56 Glass Burner Install 56 LRI4E Ceramic Burner Removal Installation 57 Fan Maintenance with GTMF Remote Control 58 Valve Replacement 59 Main Assembly 61 Vignette Faceplate 63 Arched Vignette Faceplate 64 Warranty 66 Unit dimensions with Vignette faceplate 4 Unit dimensions with Vignette faceplate small backing plate 4 Unit dimensions with Vignette faceplate small backin...

Страница 4: ...TE FACEPLATE UNIT DIMENSIONS WITH VIGNETTE FACEPLATE SMALL BACKING PLATE 24 3 16 614 14 3 4 375 22 11 16 576 35 1 16 891 30 762 21 11 16 551 18 457 1 1 16 28 20 507 14 3 8 366 24 3 16 614 14 3 4 375 23 7 8 606 37 1 8 943 30 762 21 11 16 551 1 3 16 30 17 7 8 454 20 507 14 5 16 363 ...

Страница 5: ...3 16 614 14 3 4 375 23 7 8 606 37 1 8 943 30 762 21 11 16 551 3 5 16 85 15 3 4 400 20 507 12 3 16 309 Not shown Regular backing plate 41 5 8 W x 26 H Oversize backing plate 44 W x 30 H ALL PICTURES DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS ...

Страница 6: ...Direct Vent Gas Insert dimensions UNIT DIMENSIONS WITH 4 SIDED VIGNETTE FACEPLATE BACKING PLATE 24 3 16 614 14 3 4 375 41 9 16 1056 29 1 4 743 30 762 21 11 16 551 1 3 16 30 17 7 8 454 20 507 14 5 16 363 26 660 3 1 4 83 ...

Страница 7: ...6 1 8 663 23 3 4 603 40 1 4 1023 24 3 16 614 1 11 16 43 29 7 8 758 21 11 16 551 19 7 16 494 26 1 8 663 20 507 15 7 8 403 UNIT DIMENSIONS WITH ARCHED VIGNETTE FACEPLATE BACKING PLATE 28 15 16 735 25 15 16 659 45 7 8 1165 24 3 16 614 1 13 16 46 29 7 8 758 21 11 16 551 19 5 16 491 28 15 16 735 20 507 15 3 4 399 ...

Страница 8: ...8 663 23 3 4 603 40 1 4 1023 24 3 16 614 3 3 16 81 29 7 8 758 21 11 16 551 17 15 16 456 26 1 8 663 20 507 14 3 8 365 UNIT DIMENSIONS WITH ARCHED VIGNETTE FACEPLATE SPACER BACKING PLATE 28 15 16 735 25 15 16 659 45 7 8 1165 24 3 16 614 3 5 16 84 29 7 8 758 21 11 16 551 17 13 16 452 28 15 16 735 20 507 14 1 4 361 ...

Страница 9: ...nd the fireplace re approved by the authority having jurisdiction Cet appareil doit être installé conformément aux codes et règlements locaux ou en l absence de tels règlements conformément au National Fuel Gas Code ANSI Z223 1 ou au CSA B149 1 en vigueur Cet appareil doit être utilisé uniquement avec le type de gaz indiqué sur la plaque signalétique Cet appareil n est pas convertible pour être ut...

Страница 10: ... glass doors certified with the appliance only Pour utilisation uniquement avec les portes en verre certifiées avec l appareil o For use only with barrier Part 399 100 Follow installation instructions Pour l utilisation seulement avec l écran de sécurité Pièce n 399 100 VENTED GAS FIREPLACE HEATER NOT FOR USE WITH SOLID FUELS FOYER AU GAZ VENTILÉ NE PAS UTILISER AVEC UN COMBUSTIBLE SOLIDE Model Mo...

Страница 11: ...e grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless ...

Страница 12: ...DDLERS YOUNG CHILDREN ANDOTHERATRISKINDIVIDUALSOUT OF THE ROOM AND AWAY FROM HOT SURFACES A BARRIER DESIGNED TO REDUCE THE RISK OF BURNS FROM THE HOT VIEWING GLASS IS PROVIDED WITH THIS APPLIANCE AND SHALL BE INSTALLED FOR THE PROTECTION OF CHILDREN AND OTHER AT RISK INDIVIDUALS IFTHE BARRIER BECOMES DAMAGED THE BARRIER SHALL BE REPLACED WITHTHEMANUFACTURER SBARRIER FOR THIS APPLIANCE ANY SAFETY S...

Страница 13: ...roximately 60 seconds If there is no flame ignition rectification the board will stop sparking for approximately 35 seconds After wait time the board will start second try for ignition by sparking for approximately 60 seconds If there is still no positive ignition the board will go into lock out The system will need to be reset as follows a Turn the system off using ON OFF switch or press ON OFF b...

Страница 14: ...staller service agency or gas supplier AVERTISSEMENT Quiconque ne respecte pas à la lettre les instructions dans la présente notice risquede déclencher un incendie ou une explosion entraînant des dommages des blessures ou la mort Une installation d ajustement de modification de service ou d entretien peut provoquer des blessures ou des dommages matériels Reportez vous au manuel du propriétaire de ...

Страница 15: ...atteries Ambient temperature ratings 0 50o C 32 122o F Radio Frequency 315 MHZ ATTENTION Turn OFF the main gas supply of the appliance during installation or maintenance of the Receiver device Turn OFF main gas supply to the appliance prior to removing or rein serting the batteries In case of remote control malfunction turn off the IFC device using the ON OFF main switch For installation maintenan...

Страница 16: ...t by one step until the flame is turned off The Up Arrow Key will increase the flame height each time it is pressed If the Up Arrow Key is pressed while the system is on but the flame is off the flame will come on in the high position Fig 7 8 A single beep will confirm reception of the command Fig 7 Fig 8 Room Thermostat Transmitter Operation The Remote Control can operate as a room thermostat The...

Страница 17: ...rculating fan the speed of the fan can be controlled by the Proflame system The fan speed can be adjustedthroughsix 6 speeds ToactivatethisfunctionusetheModeKey fig 1 to index to the fan control icon Fig 13 Use the Up Down Arrow Keys fig 1 to turn on off or adjust the fan speed fig 14 A single beep will confirm reception of the command Figure 13 Figure 14 Remote dimmer control Light The auxiliary ...

Страница 18: ... intermittent pilot ignition system IPI to a continuous pilot ignition system CPI by using the silver toggle switch located on the fireplace See noted location of CPI IPI Switch The benefits of having CPI are as follows Keeps venting primed for trouble free start up under colder weather conditions or inversions Keeps the unit glass warm which decreases the amount of condensation on start up Provid...

Страница 19: ... the factory built fireplace as long as these items are saved and are reinstalled in the event that the Insert is removed The fireplace flue damper can be fully blocked open or removed for installation of the gas fireplace insert Smokeshelves shieldsandbafflesmayberemoved if attached by mechanical fasteners If any part is removed it must not weaken the structural integrity of the factory built fir...

Страница 20: ... 6 Slide the unit fully into the fireplace Level if necessary 7 Hook up 120 volt AC power cord into a suitable receptacle Optional Install 4 batteries in receiver Batteries only serve as back up if power is lost within the home 8 Test gas pressure Refer to section Gas Pipe Pressure Testing Check aeration system Refertosection GasInsertAerationSystem 9 Install standard and optional features Refer t...

Страница 21: ... B Ceiling 60 1524mm From Base of Unit C Mantel Min Height 32 813mm 35 889mm From Base of Unit From Base of Unit D Min Hearth Depth 14 356mm E Min Hearth Length 40 1016mm G Max Mantle Depth 0 12 305mm 44 1118mm from bottom of unit K Min Alcove Width 54 1372mm L Max Alcove Depth 36 914mm M Mantel Deflector 3 1 2 89mm NOTE 40 1016 mm wide x 14 356mm deep hearth is required unless the unit is raised ...

Страница 22: ... location where it is to be installed Ensure that the Insert is level 4 Do not cut any sheet metal parts of the fire place in which the gas fireplace insert is to be installed 5 If the factory built fireplace has no gas access hole s provided an access hole of 1 1 2 37 5mm or less may be drilled though the lower sides or bottom of the firebox in a proper workmanship like manner This access hole mu...

Страница 23: ... of the unit See diagram below of location The Flue connection is complete when the Flue Connector Plate is fully forward and the Rear Tabs are fully engaged 6 Remove the Flue Connector Tool and store for future use 2 Attach the Flue Liners onto the Flue Connector Plate using non RTV type sealant then fasten with 3 screws See the section in this manual on Venting installation 3 Position the unit i...

Страница 24: ...t can be adjusted up to 5 16 16mm Remove left and right side filler pieces The rear levelling bolts are located in the back corners of the firebox and can be adjusted using a 7 16 wrench Rotate the bolts clockwise to raise the rear of the firebox When the appliance is in position adjust the bolts to level the appliance making sure that the appliance is also level and is sitting on the 2 bolts to p...

Страница 25: ... primary air setting Below you will see a chart showing the minimum primary air settings These are set from the factory but due to fuel conversions or installation conditions the air setting may need to be adjusted Close Open Unit Fuel Type Min Air Setting LRI4E NG 3 16 5mm LRI4E LP 1 4 6mm HRI4E NG 3 16 5mm HRI4E LP 1 4 6mm HRI4E w optional driftwood logs NG Fully Open AIR SHUTTER ADJUSTMENT 1 Sl...

Страница 26: ...best to consult with your local authorities and the CAN CGA B149 installation code For USA installations follow local codes and or the current National Fuel Gas Code ANSI Z223 1 When using copper or flex connectors use only approved fittings Always provide a union so that gas lines can be easily disconnected for servicing Flare nuts for copper lines and flex connectors are usually considered to me...

Страница 27: ... 120 volt power lost within the home PROFLAME REMOTE SYSTEM GTMF WITH FAN LRI4E HRI4E CAUTION Labelallwirespriortodisconnection whenservicingcontrols Wiringerrorscancause improper and dangerous operation Caution Ensure that the wires do not touch any hot surfaces and are away from sharp edges Proflame Remote Operation Proflame Remote Battery Change Proflame System Configuration 886 GTMF Wire Diagr...

Страница 28: ...ated near the gas valve Disconnect greenTH wire Green Wires White Connector 3 Connect one thermostat lead to female connector using male spade con nector see picture below CAUTION Do not wire Thermostat wires to 120V wire 4 Connect the other thermostat lead to male connector disconnected from Step1using a female spade connector see picture below When complete turn remote receiver to the ON positio...

Страница 29: ...rted appliance is checked as specified in the manufacturer s instruc tions supplied with the kit THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION Side control cover Cable from motor The valve in the LRI4E is attached using 2 screws and 2 hooks located below the valve Loosening the screws part way and lift the valve to disengage the hooks The valve will t...

Страница 30: ...outlet pressures at full load With a soapy solution leak test the entire system Verify both the correct flame and pilot appearance 12 See Gas Pipe Pressure Testing in manual 13 Adjust aerations settings see Air Shutter Adjustment section in the manual 9 Remove pilot retainer clip with pliers and pull off the pilot cap to expose the pilot orifice 10 Unscrew the pilot orifice with the allen key then...

Страница 31: ...olcanic Stones DO NOT cover burner ports or pilot light that leads to pilot flame BURNER PACKAGES Unit Glass Crystals Fire Beads Stones Spa Ceramic Volcanic Stones Pebbles Driftwood Logs HRI4E 8 lbs 5 lbs burner 3 lbs firebox 8 lbs 5 lbs burner 3 lbs firebox 7 lbs Glass burner 1 package 70 Spa Stones 8 lbs Beads burner 1 package 70 Spa Stones 4 lbs Glass burner 26 Volcanic Stones 8 lbs Beads burne...

Страница 32: ...32 LRI4E HRI4E 11 Direct Vent Gas Insert installation HZI390E ADDENDUM CAUTION DO NOT place spa stones over pilot and burner ports No spa stones in this area ...

Страница 33: ...t HRI6E HRI4E units Pilot shield HRI4E units only Lava Rock and Embers 1 2 3 4 7 6 5 Glass Beads quantities with Log installation HRI4E 6 lbs HRI6E 9 lbs Note Ifglasspreviouslyinstalled remove2lbstoequalabovequantity 2 Both HRI4E HRI6E Units Sweep glass aside from pilot covers if already installed to install Rear Log Bracket Rest the front edge of the Rear Log Bracket on the back of the burner scr...

Страница 34: ...cator is for the HRI6E units 1 2 3 5 Place Log 3 rest on Log 2 match pin locator on Log 3 with landing pin on Log 1 Angle the longest point on Log 3 is approximately 1 4 from the outside edge of the burner tray Line up pin locator and pin Logs 1 3 Line up pin locator and pin Logs 1 4 Line up pin locator and pin Logs 5 4 1 2 9 1 4 1 2 3 Place Log 1 on Rear Log Bracket in front of tabs ensure Log is...

Страница 35: ...va rocks on the glass as shown below Note Properly positioned Logs 3 4 should measure 1 4 from their longest point to the outside edge of the burner tray 4 3 1 4 1 4 11 Reinstall Glass Door 12 Adjust aeration setting to fully open manual for detailed instructions Note Logs to be installed in NG units only Position Log 6 Position Log 7 Place Lava Rock and Embers on Glass 3 HRI6E HRI4E ...

Страница 36: ...ing Read the instructions below carefully and refer to the images If the logs are broken do not use the unit until they are replaced Broken logs can interfere with pilot operation Improper positioning of the logs may create carbon build up and can alter the unit s performance which is not covered under warranty For Touch Ups Satin Black paint is included for burner and Dark Brown Paint is included...

Страница 37: ...he far right of the burner in the orientation shown below 8 Line up the pin locator in Log 7 with the pin in Log 1 9 When Log 7 is seated manoeuvre it is contacting Log 2 Placement of Log 4 Location for Log 5 Final Install Log 7 and Log 2 should make contact Log 7 pin locator line up with Log 1 pin Location for Log 6 4 1 7 2 7 3 5 6 1 1 2 3 4 6 7 5 5 Seat Log 4 into front right depression on burne...

Страница 38: ...aid in keeping the flue slightly warmer than the outside air making start up a smoother process STANDING PILOT Exhaust Baffle Screws help to locate the Exhaust Baffle when installing in the Firebox Exhaust Baffle Exhaust Baffle Screws both sides Exhaust Baffle Screw Heat Exchanger Return Heat Exchanger Return ADDING THE HEAT EXCHANGER RETURN 1 Remove the panels if they are already installed Remove...

Страница 39: ...re they haven t been damaged during shipping 3 Install the rear brick panel by placing it against the rear of the firebox The bottom of the brick panel rests on a small sheet metal lip just above the air intake at the bottom rear of the Firebox You will need to hold this panel in place while you install the right brick panel Do not let go of the panel or it may fall forward and be damaged 4 While ...

Страница 40: ...r Side sits between the rear liner and the firebox side When the side liner is properly installed the front edge should sit just inside the front edge of the firebox Interlocking of the side and rear Firebox Liners Insulation Panels Firebox Liner Rear Side and Rear Panel Positioning Bottom Right of Firebox Firebox Liner Retainers Exhaust Baffle Top Right of Firebox 3 Install the firebox liner Left...

Страница 41: ...or latch 6 Pull the bottom of the door towards you until the door is angled away from the firebox by about 30 Lift the door up and over the upper door hooks 7 To install the glass door reverse steps Door Components Window Glass Window Glass Gasket Door Frame Window Clip x4 Glass Gasket Retainer 1 Insert the door tool into the lower door latch WARNING Do not operate the appliance withtheglasspanels...

Страница 42: ...n VIGNETTE FACEPLATE W SAFETY SCREEN INSTALLATION Final Install Note Shown with Optional Hearth Trim 4 Ensure finger prints or smudges are removed from the faceplate before the first firing NOTE Pull the bottom of the Vignette faceplate towards you to access the remote receiver Power Cord Location Pop out tab on right side of outer faceplate Black Chrome Handling Instructions All hand and finger m...

Страница 43: ...e 2 Remove 4 screws from the back of the Vignette faceplate in loca tions shown below to remove the safety screen assembly INLAY INSTALLATION Final Install Remove 4 screws to remove safety screen assembly 3 Position the inlay face down on the back of the Vignette faceplate and reinstall the safety screen assembly reverse Step 2 4 Reinstall the Vignette faceplate with inlay onto unit reverse Step 1...

Страница 44: ...ect Vent Gas Insert installation 4 SIDED FACEPLATE WITH SAFETY SCREEN INSTALLATION 1 Install the outer faceplate and secure with 5 screws as shown 2 Install the outer faceplate by hooking the flange over the hanger as shown ...

Страница 45: ...Attach the 3 piece spacer to the back of the outer faceplate from the front with 7 screws 3 along the top and 2 on each side 3 Separate the Outer Faceplate from the Backing Plate by removing 7 screws 5 Reinstall the outer faceplate and spacer reverse Step 2 6 Reinstall the Vignette faceplate and safety screen to complete 2 Remove the outer faceplate by removing the 5 screws as shown Note the two t...

Страница 46: ... Attach the backing plate to the outer faceplate from the front with 7 screws 3 along the top and 2 on each side 4 Reinstall the outer faceplate and backing plate reverse Step 2 5 Reinstall the Vignette faceplate and safety screen to complete tooltip 2 Remove the outer faceplate by removing the 5 screws as shown Note the two top and two bottom screws can be loosened slide the outer faceplate up on...

Страница 47: ...e innerVignette frame by hanging tabs into slots on innerVignette frame The bottom of the outer faceplate will be held in position by magnets Install safety screen Install 4 screws onto unit Keyholes on inner Vignette frame tooltip tooltip tooltip Install outer Vignette frame onto inner Vignette frame tooltip 4 Install the safety screen into the inner Vignette frame by slightly tilting the safety ...

Страница 48: ...ompleted Arch Vignette Faceplate with spacer and backing plate installed 2 Attachthebackingplatewith4screwsfromthebackoftheVignetteframe Install backing plate to inner Vignette frame with 4 screws 3 Install the backing plate inner Vignette frame and outer Vignette frame as per Arched Vignette frame instructions OPTIONAL BACKING PLATE INSTALLATION ...

Страница 49: ... MANTEL DEFLECTOR INSTALLATION 4 Install the mantel deflector in between the back of the outer face plate and the front of the backing plate Insert the screws from the front of the outer faceplate using 3 screws 5 Reinstall the outer faceplate and spacer reverse Step 2 6 Reinstall the Vignette faceplate and safety screen to complete 2 Remove the outer faceplate by removing the 5 screws as shown No...

Страница 50: ... used as the measuring point to the hearth to measure the height required 2 Reattach the top piece of the hearth trim to the cut bottom piece by fitting in place 6 Line up the hearth trim with base of the unit and secure it with 3 screws as shown below 152 mm 51 mm Spacer Brackets Attach the hearth trim and spacer bracket with 3 screws each side Spacer Brackets Hearth Trim Front Part 4 Attach the ...

Страница 51: ...an be adjusted up to maximum 6 1 Discardthespacerbrackets asthesearenotrequiredwheninstalling the unit without spacer 2 Cut the top of the bottom piece of the hearth trim to the appropriate height using a metal cutting blade NOTE The tab bends at the back of the top piece of the hearth trim should be used as the measuring point to the hearth to measure the height required 4 Line up the hearth trim...

Страница 52: ...the door glass removed 5 Verifythatallventingandthecapisunobstructed 6 Verify log glass crystal placement If the pilot cannot be seen when lighting the unit the logs crystals or the embers have been incorrectly positioned 7 Theunitshouldneverbeturnedoffandonagain without a minimum of a 60 second wait 8 When lighting the appliance the inside of the glass may fog up This will burn off after a few mi...

Страница 53: ... GAS APPLIANCE This appliance must be installed in accordance with local codes if any if none follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 or Natural Gas and Propane Installation Codes CSA B149 1 CAUTION Hot while in operation Do not touch Severe Burns may result Due to high surface temperatures keep children clothing and furniture gasoline and other liquids having flammable vapors away K...

Страница 54: ...ly secured in place or with the door open 7 Do not use this appliance if any part has been under water Immediately call a qualified ser vice technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water 8 Periodically check the pilot flames Correct flame pattern has two strong blue flames 1 flowing around the flame sensor and 1 flo...

Страница 55: ...alsupportssuch as Wall Straps or plumbers tape for rigidity LOG REPLACEMENT Theunitshouldneverbeusedwithbrokenlogs Turn off the gas valve and allow the unit to cool before opening door to carefully remove the logs The pilot light generates enough heat to burn someone If for any reason a log should need replacement you must use the proper replacement log The position of these logs must be as shown ...

Страница 56: ...se tabs will not line up unless the mixing tube is inside the air shutter at the rear of the firebox Glass Media Burner Side view cut through Burner Pilot Cover Burner Screen Glass Media Tray Fill Glass Media to this level Mixing Tube Disconnect unit from gas supply and allow unit to cool before removing burner Filler section GLASS BURNER REMOVAL GLASS BURNER INSTALL 3 Place the Burner Cover Scree...

Страница 57: ...be Support Gas Orfice Pilot Assembly Air Shutter Firebox Front View Care must be taken when installing the burner into the firebox Do not damage knock or scrape the pilot assembly The flame sensor and ignition lead are fragile and can be damaged easily Satin black paint is included if touch ups are required Important Note A correctly installed burner the burner is back far enough lower the front e...

Страница 58: ...uipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug Diagram 3 Diagram 2 Before you begin Shut off the gas supply to the unit Disconnect all electrical supply to the unit Always let the appliance cool to room temperature before servicin...

Страница 59: ... 1 Remove the Left Control Panel Cover 2 Disconnect 3 wires EV1 EV2 and ground leading to the valve as shown below 3 Disconnect the Pressure Regulator cable 4 Disconnect the Gas Orifice supply line from the outlet of the Gas Valve 5 Disconnect the Pilot Supply Line from the Gas Valve 6 Disconnect the Gas Supply Line from the On Off Safety Shut off Valve 7 Remove both Screws that secure the Gas Val...

Страница 60: ...on in the Valve body casting that is designed to be used as a gripping point for assembly with other components This is the portion of the valve that can be placed in a machine vice 12 Place the Gas Valve into the machine vice using the provision as described above Do not over tighten the vice Remove the Flare Fitting from the gas outlet side of the valve 13 Remove the 2 screws that secure the lef...

Страница 61: ...23 Control Cover 904 944 90 elbow 3 8 MPT 3 8 Flare 911 228 P SIT Proflame receiver 911 074 Pilot Assy Ground Wire 396 043 Firebox Liner Retainers 396 114 Burner End L Part Description 904 943 Orifice mount 396 032 Air Shutter 396 033 Burner Mounting Bracket 396 116 Orifice Mounting Gasket 396 513 Bottom Door Latch Assy 904 946 NG orifice 37 904 947 LP orifice 53 396 125 Pilot Shield 396 046 Burne...

Страница 62: ...62 LRI4E HRI4E 11 Direct Vent Gas Insert parts list 12 ...

Страница 63: ...aceplate Vignette Georgian Iran Gray 399 835 Faceplate Vignette Tudor Metallic Black 399 836 Faceplate Vignette Tudor Iron Gray VIGNETTE FACEPLATE 1 2 3 Part Description Parts Not Shown 399 811 Vignette Door Inlay Tuscan Sunset 399 812 Vignette Door Inlay Black Chrome 399 813 Vignette Door Inlay Metallic Black 399 814 Vignette Craftsman Inlay Tuscan Sunset 399 815 Vignette Craftsman Inlay Black Ch...

Страница 64: ...99 847 Backing Plate 12 399 845 Decorative Arched Front Assembly 13 Screen and Panels Assembly 14 399 840 Spacer Assembly TOLERANCES UNLESS OTHERWISE STATED PROJECTION 3RD ANGLE FIREPLACE PRODUCTS INTERNATIONAL 7 18 4 9 10 14 3 15 16 17 1 6 2 13 12 5 QTY ATE 1 G T 1 G HT 1 E 1 ME UT 1 ME UT 1 GE 1 CH 1 G 1 VE NT 1 ND BLY 1 1 D BLY 1 2 x 2 Part Description 15 399 843 Arched Vignette Assembly 16 904...

Страница 65: ...LRI4E HRI4E 11 Direct Vent Gas Insert 65 notes ...

Страница 66: ...ol Boards Wiring Switches Blowers Blower Control Module Battery Pack Remote Control Systems 2 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crystals Firebeads Volcanic Ceramic Spa Stones 1 All hardware 1 Mesh Glass Safety Barriers 1 Accent Light Bulbs 1 Glass Crazing 1 Conditions Warranty protects against defect in manufacture or FPI factory assembl...

Страница 67: ...s installation error installation by an unqualified installer incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels lack of regular maintenance and upkeep acts of God weather related problems from hurricanes tornados earthquakes floods lightning strikes bolts or acts of terrorism or war which result in malfunction of the applia...

Страница 68: ... U S should consult their local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized selling dealer is unable to provide warranty service please contact FPI by mail at the address listed below Please include a brief...

Страница 69: ...in order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases ma...

Страница 70: ...70 LRI4E HRI4E 11 Direct Vent Gas Insert warranty ...

Страница 71: ...LRI4E HRI4E 11 Direct Vent Gas Insert 71 ...

Страница 72: ...e following information Dealer Name Address _______________________________________________ ___________________________________________________________________ Installer ____________________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No _____________________...

Отзывы: