background image

Installer

Please complete the details on the back cover and leave 

this manual with the homeowner.

Homeowner:

 

Please keep these instructions for future reference.

 

Certified to/Certifié pour: CSA 2.17-2017

                                             ANSI Z21.88-2019

                                             CSA 2.33-2019

City Series

® 

CB60E-1 DIRECT VENT 

Owners & 

Installation Manual

STYLE

 

                          

MODEL 

   

Three sided                            CB60E-NG1 / CB60E-LP1

Corner Conversion                    686-927 / 686-928 

Tested by: 

www.regency-fire.com

 

-  Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any 

other appliance. 

- WHAT TO DO IF YOU SMELL GAS

 • 

Do not try to light any appliance.

 

•  Do not touch any electrical switch: do not use any phone in your building.

 

  Leave the building immediately.

 

•  Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's 

 

instructions.

 

• If you cannot reach your gas supplier, call the fire department.

 

 

- Installation and service must be performed by a qualified installer, service agency or the gas supplier.

     

WARNING

FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly could result in serious

injury, death, or property damage.

 

920-543

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.  6988 Venture St., Delta, BC  Canada, V4G 1H4

08.18.22

Содержание City 686-927

Страница 1: ...this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed b...

Страница 2: ...e surface exceeds the limits specified in Clause 5 14 4 the following graphic danger and statements shall be shown on a Class IIIA 2 Permanent Label 4 34 6 Instruction Plate Each appliance shall bear a Class IIIB marking with letters on a contrasting background located adjacent to the controlling device or in an equally conspicuous position where the instruction can be easily read April 22 14 Crea...

Страница 3: ...al Electrical Code ANSI NFPA 70 in the U S A and the current CAN CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22 1 in Canada This Regency mobile manufactured home listed appliance comes factory equipped with four 1 4 diameter holes located near each corner of the base Fasten the fireplace in place using screw inserted through the holes This appliance comes equipped ...

Страница 4: ... the appliance s connected to the venting system are located and other spaces of the building 4 Close fireplace dampers 5 Turn on clothes dryers and any appliance not connected to the venting system Turn on any exhaust fans such as range hoods and bathroom exhausts so they are operating at maximum speed Do not operate a summer exhaust fan 6 Follow the lighting instructions Place the appliance being...

Страница 5: ...placement 107 Valve Replacement 108 Gas Maintenance Recommended Annual Routine 109 Main Assembly 110 Main Assembly 111 Accessories 112 Power Vent End of Line 113 Power Vent Inline 114 Warranty 116 Copy of Safety Decal 6 Decal Location 6 Dimensions Bay Install 7 Gas Connection Back of Unit 8 Gas Connection Bottom of Unit 8 Gas Connection Side of Unit 8 Electrical Connection Bottom of Unit 9 Electri...

Страница 6: ...ANSI NCSBCSA225 1 NFPA501A Cet appareil doit être utilisé uniquement avec les types de gaz indiqués sur la plaque signalétique et peut être installé dans une maison préfabriquée É U seulement ou mobile installée à demeure si les règlements locaux le permettent Voir la notice de l utilisateur pour plus de renseignements Une trousse de conversion est fournie avec cet appareil C 4001172 For Use Only ...

Страница 7: ...ng legs fully inserted and may vary depending on the height of the leveling legs when unscrewed or extended Dimensions will appear as inches metric mm throughout this manual The inches are rounded to the nearest 1 16 when convert ed when greater accuracy is required use the metric dimensions Note These units are non load bearing ALL PICTURES DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATI...

Страница 8: ...t Gas Connection Bottom of Unit Gas Connection Side of Unit Right Side Left Side 1 3 8 2 1 2 33 1 8 5 29 1 4 2 1 2 1 3 8 16 3 8 OPENING AT UNIT BASE 20 7 1 8 11 3 8 GAS VALVE FRONT OF UNIT BACK OF UNIT 3 3 4 7 5 8 5 6 3 4 6 3 4 5 7 5 8 3 7 8 LEFT SIDE RIGHT SIDE ...

Страница 9: ...y Series CB60E 1 9 installation Electrical Connection Bottom of Unit Electrical Connection Side of Unit 3 3 4 7 5 8 5 6 3 4 RIGHT SIDE 16 3 8 OPENING AT UNIT BASE 20 7 1 8 11 3 8 FRONT OF UNIT BACK OF UNIT ...

Страница 10: ...eveling legs fully inserted and may vary depending on the height of the leveling legs when unscrewed or extended Dimensions will appear as inches metric mm throughout this manual The inches are rounded to the nearest 1 16 when converted when greater accuracy is required use the metric dimensions Note These units are non load bearing ALL PICTURES DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUST...

Страница 11: ...rted to top or rear vent per manual instructions and the insulation discarded Venting YES NO Are the venting components approved for the unit installed Does the venting configuration comply with venting diagrams Is venting installed and secured and are clearances for the vent pipe and termination cap maintained If applicable was a 1 4 rise maintained for every foot of horizontal run Was the termin...

Страница 12: ...hutter on the proper setting after running the unit for 20 minutes If applicable were the surround and trims installed according to the manual Was the operation of the fan lights if installed and flame modulation checked Customer Tutorial and Presentation YES NO Is the customer confident operating the new gas appliance and aware of all the features on the remote Confirm that the rating and lightin...

Страница 13: ...IVIDUALS OUT OF THE ROOM AND AWAY FROM HOT SURFACES Important Message SAVE THESE INSTRUCTIONS City Line Direct Vent Fireplaces must be installed in accordance with these instructions Carefully read all the instructions in this manual first Consult the authority having jurisdiction to determine the need for a permit prior to starting the installation It is the responsibility of the installer to ens...

Страница 14: ...r valve Unit Body Firebox Different types and thicknesses of steel will expand and contract at different rates resulting in some cracking and ticking sounds will be heard throughout the cycling process During the first few fires a white film may develop on the glass front as part of the curingprocess Theglassshouldbecleaned after the unit has cooled down or the film will bake on and become very di...

Страница 15: ... performed you must disconnect the power and shut off gas to the appliance Diagram 1 4 The unit will turn on 5 Reset the system as follows a Turn the system off by pressing the ON OFF button on the remote b Wait 5 minutes then repeat the process from step 2 Lighting Procedure Continuous Pilot Intermittent Pilot CPI IPI selection See remote control instructions for details NOTE The first try for ig...

Страница 16: ...bâtiment Appelez immédiatement votre fournisseur de gaz depuis un téléphone extérieur Suivez les instructions du fournisseur Si vous ne pouvez pas rejoindre le fournisseur appelez le service incendie C N utilisez pas cet appareil s il a été plongé dans l eau même partiellement Faites inspecter l appareil par un technicien qualifié et remplacez tout élément du système de contrôle ou de commande qui...

Страница 17: ... see the receiver instruction marked The receiver will beep three times when ready to synchronize with a transmitter Install three AAA batteries in the battery bay at the base of the transmitter fig 3 Press the ON button The receiver s command is accepted and sets to the particular code of that transmitter The system is now initialized The receiver may be independent or integral to the IFC hearth ...

Страница 18: ...til the flame is turned off The Up Arrow Key will increase the flame height each time it is pressed If the Up Arrow Key is pressed while the system is on but the flame is off the flame will come on in the high position Fig 7 8 A single beep will confirm reception of the command Fig 7 Fig 8 Room Thermostat Transmitter Operation The Remote Control can operate as a room thermostat The thermostat can ...

Страница 19: ...d can be adjusted through six 6 speeds To activate this function use the Mode Key fig 1 to index to the fan control icon Fig 13 Use the Up Down Arrow Keys fig 1 to turn on off or adjust the fan speed fig 14 A single beep will confirm reception of the command Figure 13 Figure 14 Remote dimmer control Light The auxiliary function controls the AUX power outlet by the dimmable light control To activat...

Страница 20: ...y changed from an intermittent pilot ignition system IPI to a continuous pilot ignition system CPI by using remote control as noted above The benefits of having as CPI are as follows Keeps venting primed for trouble free start up under colder weather conditions or inversions Keeps the unit glass warm which decreases the amount of condensa tion on start up Provides owners with flexibility to choose...

Страница 21: ... the left right slides as shown below The battery compartment will be pushed out slightly to allow to easily extract it Extract the battery compartment from the remote receiver battery holder Close the right slide Keeping the battery compartment pressed in close the left slide Proflame II Battery Holder Battery Replacement Battery Pack up if 120 Volt Power is lost IMPORTANT Non Power Vent Model In...

Страница 22: ...emove the cover to access the IFC 3 Locate the WIFI dongle connection X0A on the left side of the IFC 4 Line up the tabs on the dongle with the notches on the IFC connection and insert the cable into the connection 5 Locate the dongle holder on the right side of the IFC 6 Slide the dongle into place with the wires at the top 7 Reinstall the IFC cover and tighten the 2 screws X0A WIFI Dongle Instal...

Страница 23: ...he corner protectors onto the bottom corners of the glass If you don t have these place a soft cloth or piece of cardboard under the glass barrier to protect the corners during removal 4 Using the vacuum clamps lift the barrier straight up pull it toward you then gently lower it straight down see below Open Vacuum clamps Closed Vacuum clamps Corner protector Corner protector Lift Pull forward Lowe...

Страница 24: ...ward you Counter clockwise angles barrier in towards the unit Slide the screwdriver straight up at the two indicator slots Glass Barrier Adjustment If the side glass height needs adjustment follow the next step To adjust the side glass remove the screws at the top of the panel and move the glass up or down When the glass is in the correct position replace and tighten the screws ...

Страница 25: ...acuum clamps When removing glass prepare a soft scratch resistant surface to place the 60 3 8 x 18 1 4 glass Never clean or remove hot glass Note The suction cups may leave a round film on the glass when used Ensure that the glass is cleaned using a fireplace glass cleaner after each removal and prior to operating the appliance Note glass panels must be installed to operate fireplace 4 Open the 8 ...

Страница 26: ...g on support Lower clamps x9 in open position Push down on levers to lower glass panel Gasket pad NOTE The firebox glass may remain propped on the glass supports to clean the interior surface Use care when cleaning do not apply excessive force or pressure 9 To remove the firebox glass panel from the unit tilt the glass forward gently onto the glass supports grip both suction clamps and lift the gl...

Страница 27: ...lass Note if gasket pad won t open check that all clamps are turned a full 90 3 Open 2x top clamps by turning 90 4 Gently move bottom of side glass panel into the support channel as shown in diagram below 5 Tilt top of glass side panel outward to create clearance 6 Remove panel 7 Repeat steps to remove side glass panel on the opposite side 8 Reverse steps to re install side glass panels ...

Страница 28: ...f the barrier glass 4 Repeat steps 1 6 to install outer panels on opposite side 5 Install barrier glass as per instructions in this manual 3 Install glass stopper if desired by sliding stopper assembly between unit and panel the stopper assembly will attach to the unit via a magnet adjust position of glass stopper is required 2 Slide backwall outer panel behind glass stopper bracket if installed 1...

Страница 29: ...ner light cover and remove 4 Replace bulb and reverse steps to complete procedure NOTE Do not handle bulb with bare hands Use packaging or a tissue to hold new bulb when replacing Regency Part 911 208 Oven Lamp Assembly G9 120V 25W Regency Part 911 072 Replacement Bulb G9 120 Volt 25 watt Light are located behind the front face of the unit Inner light covers shown from below Inner light covers clo...

Страница 30: ...ntothedoorframe Reinstallasper GlassInstallationinthe GlassInstallation section REPLACEMENT GLASS CB60E 1 Outer Safety Glass Front Tempered Part 940 511 P Outer Safety Glass Right Side Tempered Part 940 509 P Outer Safety Glass Left Side Tempered Part 940 510 P Inner Glass Front Ceramic Part 940 507 P Inner Glass Side Ceramic Part 940 508 P Maintenance Instructions 1 Always turn off the gas valve ...

Страница 31: ... in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspection ...

Страница 32: ...ug 3 prong plug for the lights into the receptacle The 3 prong plug will be located near the gas valve on the appliance 9 Final check Before leaving this unit with the customer the installer must ensure that the appliance is firing correctly and operation fully explained to customer General Safety Information 1 The appliance installation must conform with localcodesor intheabsenceoflocalcodes with...

Страница 33: ...eferto Exterior Vent TerminationLocations section E Diagram 1 D 3 sided CB60E 1 corner install E 3 sided CB60E 1 Locating Your Gas Fireplace Corner Install 1 When selecting a location for your fireplace ensure that the clearances are met 2 The appliance must be installed on a flat solid continuous surface For example a wood metal or concrete floor or in a raised on the wall application The applian...

Страница 34: ...p Leveling legs Leveling Legs There are four levelling legs two on each side that can be adjusted with the supplied tool found in the manual package if required t to oo ol lt ti ip p Remove the screws securing the unit to the pallet Due to the size and weight 480 pounds shipping weight of the CB60E 1 lifting and moving the unit will require 4 people Place a length long enough to get a solid grip o...

Страница 35: ...o the right Note Once the finished material is installed these access panels are no longer accessible tooltip tooltip Gas connection Aeration adjustment Electrical 1 Identify access panel to be removed remove corresponding outer trim panel by lifting up and off centre panel shown below 2 From inside the unit push in tab to release the access panel at the top 3 Push the access towards the inside of...

Страница 36: ...m opening height must be 1 3 4 44mm measured from top of enclosure to the ceiling and must be in open in front and both sides to meet the minimum 180 square inches free open air requirement Ventilation Opening Locations The following are examples of how the ventilation openings may be placed above the fireplace If using the optional heat wave kit this does not reduce the size of the ventilation op...

Страница 37: ...the ceiling as shown below Minimum width depth of chase x height measured from top of enclosure to the ceiling and must be in open in front and side to meet the minimum 180 square inches free open air requirement Ventilation Opening Locations The following are examples of how the ventilation openings may be placed above the fireplace If using the optional heat wave kit this does not reduce the siz...

Страница 38: ... to prevent heat from escaping anywhere above through the enclosure other than the required grill ventilation opening Internal chase When installing as an internal chase framing installation regardless of where appliance is placed within the home requires the use of either drywall or other means such as plywood on the rear wall of the chase to eliminate heat escaping into the rear wall cavity If t...

Страница 39: ...mum F Alcove Depth 35 889mm Front to Unit Maximum G Convection Air Outlet Opening Offset min 2 50mm Max offset from top of chase enclosure H Convection Air Outlet 180 square inches I Enclosure Depth min 20 5 16 516mm Minimum inside dimensions J Opening Height 18 457mm Bottom Top of Fireplace Opening K To Ceiling min all 3 sides 1 3 4 To Top of Ceiling L Chase Enclosure min 81 1 4 2064mm From base ...

Страница 40: ...top opening Full framing with vents in front 2 sides or top Full framing with low vents in front or 2 sides Full framing with vents in front or 2 sides C I A1 A D L J H L I C D A1 A J G G H H H I C G A A1 G D J L H H I A D C J G G L H H A1 opening opening opening opening ...

Страница 41: ...n illustration Clearances will be the same for the right hand side Clearance single sided Dimension Measured From A Mantel Height min Top of Fireplace Opening B Opening Height 18 457mm Bottom Top of Fireplace Opening C From Floor min 10 1 4 260mm Bottom of Fireplace Opening D Sidewall on one side min 39 991mm Side of Fireplace Opening E Mantel Depth max Front of Fireplace Opening F Alcove Depth 35...

Страница 42: ... facing are shown in the diagram on the right Mantel Leg Clearances Combustible mantel leg clearances as per diagram 2 12 6 4 8 10 0 14 9 229mm 18 1 16 459mm 10 20 26 Top of Fireplace Opening 12 305mm 1 2 13mm Drywall wood wood panel etc 5 1 4 133mm To Bottom of Fireplace Opening 12 305mm MANTEL LEG 0 ...

Страница 43: ...nchesofopenarea is required for the convection air outlet to cool the enclosure Ensure clearances for Convec tion Air Outlets are met See clearances CB60E 1 in this manual as there are different methods as to how this can be achieved Note This appliance must be installed on a solid surface suchasaplywoodfloorwhich must be the full width and depth of the appliance Ensure that the wood base that the...

Страница 44: ...l width and depth of the appliance Framing Dimensions Description Corner Kit A Framing Height 44 3 4 1137 mm B Framing Width 71 1 4 1810 mm C Framing Depth 20 5 16 516mm D Unit Base to Top Enclosure Min 81 1 4 2038 mm G Vent Centerline Height 58 3 16 1478 mm NOTE Unit cannot be load bearing All finishing materials must be supported by the framing Max 2 x 6 Max 2 x 6 Note Unit must be installed ont...

Страница 45: ...e must be in stalled on a level and solid surface such as a plywood floor which must be the full width and depth of the appliance Framing Dimensions Description Corner Kit A Framing Height 44 3 4 1137mm B Framing Width 71 1 4 1810mm C Framing Depth 20 5 16 516mm D Unit Base to Top Enclosure Min 81 1 4 2038mm G Vent Centerline Height 58 3 16 1478mm Max 2 x 6 Max 2 x 6 Note Unit must be installed on...

Страница 46: ...m guide for left or right install to the outer side panel 3 Screw removable trim on and bend tabs closest to the finishing trim inwards 90 degrees 4 Slide outer side panel down onto the two screws in the firebox body Tighten screws with screwdriver 5 Screw in the three self tapping screws at the top of the outer side panel to attach it to the firebox 6 Unit can be placed in framing and finishing m...

Страница 47: ... firebox and then pushing them in 8 Install lower inner liner panels 10 Install the inner panel for the corner conversion by wedging it into the inner lower liner panels 12 Once the inner side panel is wedged in place tighten the hanger screws for the back liner panels 11 Slide the inner side panel in by wedging it between the side glass and the back liner panels 2 CB60E CORNER ...

Страница 48: ...on and lock all the upper and lower clamps 14 Install outer liner panels there will be two left over 15 Slide the corner panel up and in to secure it 16 Slide the corner panel over to the outer side panel until contact with magnets is made 17 Install barrier glass as per instructions in the manual 3 CB60E CORNER ...

Страница 49: ... shown above by assembling 2x Part B with 2x Part H with 8 screws installed from back of frame 2 Install the frame assembled in Step 1 onto the back of the unit as shown above with 2 screws on each side 3 Place unit against wall in desired location Level the unit by adjusting 4 leveling bolts on unit 4 Install venting before proceeding further with framing kit construction Refer to manual for vent...

Страница 50: ... to upper and lower Part B of the back frame with 2 screws each as shown Before installing Part I turn it so that the side screw holes are on the lower end next to lower Part B 7 Attach the 4 x end pieces Part J to the upper and lower Part B of the back frame with two screws each 8 Attach 2 x Part G to the previously installed Part J parts with 2 screws at each end 9 Attach end cross braces Parts ...

Страница 51: ...all 4 horizontal mid braces Part K with one screw on each end installed from the top 12 Install 4 front supports Part C to upper and lower Part A with 2 screws on each end Before installing Part C turn it so that the screw holes are at the top 13 Install 2 top and 2 inner diagonal supports Part D with 2 screws at each end Part K Part D Part ID overview Part C screw holes ...

Страница 52: ...osure Max 2 Stud Stud Stud Stud 60 Chase Vent 60 Chase Screw to studs here Vent Finishing material Finishing material Opening for vent 3 3 5 Min 60 25 Framed Opening must be between 3 and 3 5 tall and at least 60 25 wide to accomodate the Chase vent The top of the chase vent opening must be 2 Chase Vent is installed after finishing material or less from the top of the chase enclosure ...

Страница 53: ...as line or damage valve or electrical components Note It is acceptable to use a high temperature silicone sealant to adhere drywall to lower access cover panel The appliance is designed to be used with a minimum 1 2 in wall sheathing materials such as drywall plywood wood composites or non combustible materials Thicker materials may be used Refer to facing and finishing details in this manual Faci...

Страница 54: ...As this appliance has been designed with all hot air escaping through the chase enclosure ventilation grill openings only if hot air is trapped as a result of the hot air escaping through joints crevasses open studs or other openings within the enclosure above this will change the clearances within the enclosure causing the enclosure to overheat It is vital that all the hot air from within the enc...

Страница 55: ...City Series CB60E 1 55 installation 2 x 4 shown Max 2 x 6 Typical Installations Flush Install Recessed Install ...

Страница 56: ...nting bracket cannot be secured directly to the appliance It must be secured to framing The TV depicted in the pic ture may need to be higher depending on the style of TV mounting bracket used Typical Installations Flush TV with Hearth Maximum TV Recess ...

Страница 57: ... surface Recess Install Example Flush Install Example Finish up to trim on all 4 sides Loosen screws using supplied Offset Screwdriver and remove bottom and side trim pieces Front edge of side liner panels must not be covered by finishing material or removal of the Firebox Glass will not be possible Bottom edge should be flush with top surface of Inner Liner Panel ...

Страница 58: ... type batteries in the battery compartment with the correct polarity 6 Place the slider into the cover plate 7 Put the Battery Holder switch in the OFF position to allow correct lineup for slider switch 8 Make sure the Battery Holder and cover plate words ON and UP are on the same side 9 Align the slider with the switch on the Battery Holder and couple the switch into the slider 10 Align the screw...

Страница 59: ...rences can reduce the operative distance of the device Make sure to attach the adapter in a level plane without any distortion Proceed as follows Detach the adapter from the body of the remote control see Fig A Position the adapter on the wall mark the points for the fixing holes and drill the wall Fix the adapter on the wall using the mounting hardware supplied with the remote control Insert the ...

Страница 60: ...bove meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 30cm 9 23cm L Clearance to a mechanical air supply inlet 3 91cm above if within 10 3m horizontally 72 1 8m 36 90cm b M Clearance above paved sidewalk or a paved driveway located on public proper...

Страница 61: ... 58DVA CS 5DT CSS 5DRS TM 5SS DV CSS05 Wall Support Band 58DVA WS 5DT WS B 5DWS TM 5WS VDV WS05 Offset Support 58DVA ES 5DT OS N A TM 5OS N A Wall Thimble Black 58DVA WT 5DT WT 5DWT N A VDV WPT05 Wall Thimble Support Ceiling Support 58DVA DC N A N A N A N A Firestop Spacer 58DVA FS 5DT FS 5DFS TM 5LS VDV FS05 Trim Plate Black 58DAV WFS 5DT TP 5DCP TM 5TP VDV WTC05 5 X 8 RIGID PIPE CROSS REFERENCE ...

Страница 62: ...with all rigid piping 946 506 P Vent Guard Optional 946 606 Starter collar reducer 5 x 8 to 4 x 6 5 8 B36XTE B36XTCE ONLY 946 625 Vinyl Siding Standoff AstroCap XL Note When using Metal Fab Sure Seal Rigid Piping please note that the Adaptor 5DDA must be used in conjunction with FPI Rigid Pipe Adaptor 770 994 Not available applicable for the following units B41XTE B41XTCE CB60E CV60E CV72E HZ54E U...

Страница 63: ...rams refer to the following instructions 1 Remove the safety barrier glass and firebox glass see instructions in this manual 2 Adjust the vent restrictor plate to the required vent restrictor position as per the diagrams shown 3 Once the vent restrictor plate is in the required position secure with screws Vent Restrictor Position t t o o o o l l t t i i p p Front of Unit Back of Unit Vent Restrict...

Страница 64: ...These venting systems in combination with the CB60E 1 Direct Vent Gas Fireplace has been tested and listed as a direct vent heater system by Intertek The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in Exterior Vent Termination Locations section Regency Direct Vent Flex System Termination Kits include all the parts needed to install the CB...

Страница 65: ...tside wall making sure that the tabs are on top and bottom Fasten the other thimble half to the inside wall The thimble halves slip inside each other and can be adjusted for 2 x 4 or 2 x 6 walls 5 Slip the assembled liner and termination as sembly through the thimble making sure the termination cap faces up there are markings on the cap that show which way is up This will position the termination ...

Страница 66: ...e combinations of vertical runs with horizontal terminations using one 90o two 45o elbows equal one 90o elbow Note Must use optional rigid pipe adapter Part 770 994 when using Rigid Pipe Venting Systems Maintain clearances to combustibles as listed in Clearances section Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall A v...

Страница 67: ...entDirect Vent SelkirkDirect Temp Ameri Vent Direct Venting ICC Excel Direct Olympia Ventis DV and Security Secure Vent systems Use of these systems with the Rigid Pipeadaptorisdeemedacceptableanddoesnot affect the Intertek WHI listing of components WARNING Do not combine venting components from different venting systems However use of the the AstroCapTM and FPI Riser is acceptable with all system...

Страница 68: ...ine requirements If the wall being penetrated is constructed of non combustible material i e masonry block or concrete an 8 203mm diameter hole is acceptable Notes a The horizontal run of vent must be level or have a 1 4 inch rise for every 1 foot of run towards the termination Never allow the vent to run downward This could cause high temperatures and may present the possibility of a fire b The l...

Страница 69: ...eet otherwise rigid venting must be used H H1 V Horizontal Venting with Two 2 90o Elbows One 90o elbow Two 45o elbows Option V H H1 With these options maximum total pipe length is 30 feet with minimum of 6 feet total vertical and maximum 8 feet total horizontal Pleasenoteminimum 1 foot between 90o elbows is required A 1 Min 2 Max B 2 Min 4 Max C 3 Min 5 Max D 4 Min 6 Max E 5 Min 7 Max F 6 Min 8 Ma...

Страница 70: ... 25 0 99 over 11 12 to 12 12 4 1 22 over 12 12 to 14 12 5 1 52 over 14 12 to 16 12 6 1 83 over 16 12 to 18 12 7 2 13 over 18 12 to 20 12 7 5 2 29 over 20 12 to 21 12 8 2 44 Pipe Length Vertical Terminal Storm Collar Flashing Ceiling Firestop Rigid Pipe Adapter This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with Duravent Direct Vent Selkirk Direct Temp Ame...

Страница 71: ...e Clearances section Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall Must use optional rigid pipe adaptor Part 770 994 when using rigid pipe vent systems Refer to the Vent Restrictor Position section for details on how to change the vent restrictor from the factory setting of Set 0 through to Set 3 if required Maximum 36...

Страница 72: ...whenever passing through a wall Must use optional rigid pipe adaptor Part 770 994 when using rigid pipe vent systems Vertical Venting with Three 3 90o Elbows One 90o elbow Two 45o elbows V H1 H V1 Option V H H1 V V1 With these options max totalpipelength is 30 feet with min of 10 feet total vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is required A 1 Min 2 Max...

Страница 73: ...flex pipe to pipe adaptor using Mill Pac over the adaptor Slide the inner pipe over the flex to rigid adaptor and secure with 3 screws 12 Repeat Step 11 to secure outer flex 3 Cut a hole in the roof centered on the small hole placed in the roof in the previous steps The hole should be a minimum of 11 279 mm The hole may be round and or square 4 Slip the flashing under the shingles and line up flas...

Страница 74: ...rchased separately See Simpson Duravent components list in the instruction manual for part numbers Flex Pipe Ceiling Firestop Roof Support Brace Flashing Storm Collar Termination Cap Ceiling Firestop Enclosure Flex Pipe Ceiling Firestop Roof Support Flashing Elbow Support Termination Cap Storm Collar Ceiling Firestop Support to prevent sagging Enclosure Ceiling firestop Flashing Termination Cap St...

Страница 75: ...r and slip the 5 127 mm inner flex pipe from the Vertical termination kit over the flex adapter ensuring that the inner flex pipe overlaps the collar by at least 1 4 35 mm Fasten with 3 screws 4 Apply a bead of Mill Pac around the perimeter of the 8 203 mm outer collar of the flue adapter and slip it over the 8 203 mm outer flex pipe from the vertical termination kit ensuring that the outer flex p...

Страница 76: ...d in conjunction with the 946 755 Vertical flex kit and 946 756 kit Vertical flex extension kit Horizontal power vent kit Firestop spacer to prevent debris from falling into the ceiling firestop Aceiling firestop firestop spacer must be installed when passing through each floor orceiling level Toinstall theceilingfirestop firestop spacer in a flatceiling or floor joist cut a 279 mm square hole Fra...

Страница 77: ...rds the back of the unit and then out 4 Bring the wiring from inside the wall through the opening created when the plate was removed in the previous step 5 Wire the electrical box NOTE The receptacle and receptacle cover may be located in the manual pack and may need to be installed 6 Feed any excess wiring into the wall and reinstall the plate onto the wall of the unit 7 Reinstall electrical box ...

Страница 78: ...V A C power supply it is highly recommended as a primary power source Batteries 4 AA should be used as a secondary power source only CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Ensure that the wires do not touch any hot surfaces and are away from sharp edges This appliance is equipped with a three prong grounding p...

Страница 79: ... USA installations follow local codes and or the current National Fuel Gas Code ANSI Z223 1 When using copper or flex connectors use only approved fittings Always provide a union so that gas lines can be easily disconnected for servicing Flare nuts for copper lines and flex connectors are usually considered to meet this requirement NOTE A shutoff dante valve should be supplied in or near the unit ...

Страница 80: ...ower is installed after a negative run for every foot of negative run the inline blower must be an equal distance or greater from the 90 degree elbow See example above IMPORTANT Maximum total vent length based on overall length of Maximum total vent length based on overall length of combined chimney components 72 22 m combined chimney components 72 22 m Maximum total negative vent length 7 2 1 m M...

Страница 81: ... be reduced to 4 x 6 5 8 102 mm x 168 mm in all ap mes with a 5 127 mm inner and an 8 203 mm outer collar which must be reduced to 4 x 6 5 8 102 mm x 168 mm in all ap plications plications Must be terminated horizontally Vertical ter Must be terminated horizontally Vertical terminations are not permitted minations are not permitted RIGID PIPE MUST USE RIGID PIPE ADAPTOR 770 994 AND 946 606 PIPE RE...

Страница 82: ...d vacuum clamps When removing glass prepare a soft scratch resistant surface to place the 70 3 8 x 15 1 4 glass Never clean or remove hot glass Note The suction cups may leave a round film on the glass when used Ensure that the glass is cleaned using a fireplace glass cleaner after each removal and prior to operating the appliance Note glass panels must be installed to operate fireplace glass supp...

Страница 83: ... supports Lower clamps x9 in open position Push down on levers to lower glass panel Gasket pad NOTE The firebox glass may remain propped on the glass supports to clean the interior surface Use care when cleaning do not apply excessive force or pressure 9 To remove the firebox glass panel from the unit tilt the glass forward gently onto the glass supports grip both suction clamps and lift the glass...

Страница 84: ...ssure on the glass 4 Slide the corner protectors onto the bottom corners of the glass 5 Holding the glass barrier in front of the unit slide it up behind the top lip of the unit Lift the barrier up as far as it goes then hook the barrier onto the unit Push forward Lower onto hooks Lift up Slide behind top lip Open Vacuum clamps Closed Vacuum clamps Corner protector Corner protector 6 Visually insp...

Страница 85: ...rd you Counter clockwise angles barrier in towards the unit Slide the screwdriver straight up at the two indicator slots Glass Barrier Adjustment If side glass height needs adjustment follow the next step To adjust the side glass remove the screws at the top of the panel and move the glass up or down When the glass is in the correct position replace and tighten the screws ...

Страница 86: ...the barrier glass 4 Repeat steps 1 6 to install outer panels on opposite side 5 Install barrier glass as per instructions in this manual 3 Installglassstopper ifdesired byslidingstopperassemblybetweenunit and panel the stopper assembly will attach to the unit via a magnet adjust position of glass stopper is required 2 Slide backwall outer panel behind glass stopper bracket if installed 1 Install g...

Страница 87: ...operation of the converted appliance is checked as specified in the manufacturer s instructions supplied with the kit THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION Cable from motor Conversion Kit 686 969 includes 1 911 191 Stepper Motor LP for 885 SIT 1 905 046 Orifice 50 1 910 037 Pilot Orifice 30 1 918 590 Decal Conversion to LP 1 908 528 Label Prop...

Страница 88: ...ip Burner Orifice Location 12 Loosen 8 screws in locations shown below 4 at front and 4 at rear slide burner to the left away from the orifice and lift out Burner screw locations Slide burner to the left and lift out City Series LP SYSTEM DATA Min Supply Pressure 11 WC 2 73kpa Manifold Pressure High 10 5 WC 2 62 kpa Manifold Pressure Low 2 9 WC 0 72 kpa Orifice Size 50 DMS Maximum Input 36 000 Btu...

Страница 89: ...ividual inner light cover and remove 4 Replace bulb and reverse steps to complete procedure NOTE Do not handle bulb with bare hands Use packaging or a tissue to hold new bulb when replacing Regency Part 911 208 Oven Lamp Assembly G9 120V 25W Regency Part 911 072 Replacement Bulb G9 120 Volt 25 watt Light are located behind the front face of the unit Inner light covers shown from back of unit back ...

Страница 90: ...ass see manual for instructions 2 On back of firebox wall install 6 screws loosely in locations shown below Install3backpanels hangpanelsoninstalledscrewsthrough keyhole opening 3 Reinstall firebox glass see instructions in manual 3 Slidebackwallouterpanelbehindglassstopperbracket ifinstalled 1 Install outer side panel as shown below 2 Install glass stopper if desired by sliding down the outside o...

Страница 91: ...osite side 8 With panel set installed complete by installing barrier glass 9 Reverse all steps to remove panels 5 Install middle outer panel 6 Install glass stopper if desired by sliding stopper assembly between unitandpanel thestopperassemblywillattachtotheunitviaamagnet Adjust position of glass stopper as required ...

Страница 92: ...ure to do this will result in burn stain on panels which you will be unable to remove Not protected by product warranty The CB60E has optional enamel inner panels that may be installed CB60E outer panels and 8 inner panels Turn off power and gas to unit and allow to cool to room temperature Remove the safety glass and firebox glass see manual for instructions CB60E OUTER PANELS 1 Install 5 inner b...

Страница 93: ...wn below 5 Install middle outer panel 6 Install glass stopper if desired by sliding stopper assembly between unit and panel the stopper assembly will attach to the unit via a magnet adjust position of glass stopper is required 7 Repeat steps 1 6 to install outer panels on opposite side 8 With panel set installed complete by installing barrier glass 9 Reverse all steps to remove panels CITY SERIES ...

Страница 94: ...and manoeuvre into position sliding the bottom into the corner and back brackets 8 Secure the top of the panel brackets with 2 screws into 2 brackets each panel has 2 brackets 4 Install inner base panel sets 3 4 5 6 7 8 metal panels first then glass panels on top tooltip Slide back panel into base brackets Secure 2 top brackets 9 Repeat Steps 7 8 to install back panels 10 11 10 When completed inst...

Страница 95: ... bracket if installed 14 Install outer corner panel 14 as shown below 15 Install middle outer panel 15 17 Repeat steps 1 6 to install outer panels 16 17 18 on the op posite side 18 After complete panel set installed complete by installing barrier glass 19 Reverse all steps to remove panels 16 Install glass stopper if desired by sliding stopper assembly between unit and panel the stopper assembly w...

Страница 96: ... burner only in amounts noted below CB60E 1 Approved Media Where Used Quantity Fireglass starfire copper or black On burner 2 lbs Glowing embers sea wool supplied with unit On burner 1 bag Crushed Glass Coal Black 3 4 Around burner 2 boxes 7 lbs Crushed Glass Iceburg chips Around burner 2 boxes 7 lbs Firebeads Around burner 7 lbs Stone River Pebbles Around burner 1 box Stone Ceramic Spa Around bur...

Страница 97: ...of center 10 Right Cross Log right of center 11 Right Cross Log 2nd right from center 12 Left Cross Log far left log 13 Right end log Log Guides 3 2 lb Black Fireglass purchased separately from log set Glowing Wool supplied with unit 3 4 Crushed black glass or iceburg chips purchased separately from log set 1 Shutoffgasandelectricalsupply allowunittocooltoroomtemperature 2 Remove barrier glass if ...

Страница 98: ...he panel as shown below 11 Insert the pin of Log 6 into the hole on the right side of the pilot Posi tion the right end of Log 6 2 from the edge of the panel 12 Insert the pin of Log 7 into the hole on the right most side Position the left end of the log 1 1 8 from edge of panel as shown below 3 1 2 1 1 4 4 10 Insert the pin of Log 5 into the hole on the left side of the pilot Position the left en...

Страница 99: ...e part of the Y of Log 10 on the landing in Log 6 Rest the opposite end of Log 10 on Log 2 as shown below 15 To install Log 9 line up the pin locator on Log 9 with the pin on Log 1 and place the other end on the landing on Log 5 as shown below 9 5 2 2 10 6 11 3 7 18 Install Log 12 with one end resting on the far left side of the burner and the other on the left end of Log 4 as shown below 4 4 19 I...

Страница 100: ... Left Cross Log left of center 10 Right Cross Log right of center 11 Right Cross Log 2nd right from center 12 Left Cross Log far left log 13 Right end log Log Guides 3 2 lb Black Fireglass purchased separately from log set Glowing Wool supplied with unit 3 4 Crushed black glass or iceburg chips purchased separately from log set 1 Shutoffgasandelectricalsupply allowunittocooltoroomtemperature 2 Rem...

Страница 101: ...ge of the panel as shown below 11 Insert the pin of Log 6 into the hole on the right side of the pilot Posi tion the left end of Log 6 3 4 from the edge of the panel 12 Insert the pin of Log 7 into the hole on the right most side of the burner Position the left end of Log 7 1 5 8 from edge of panel as shown below 3 2 1 10 Insert the pin of Log 5 into the hole on the left side of the pilot Position...

Страница 102: ... Log 9 line up the pin locator on Log 9 with the pin on the left side of Log 1 and rest the Y of Log 9 over Log 5 9 5 1 5 10 1 6 18 Install Log 12 with one end resting on the far left side of the burner and the other on the right end of Log 4 as shown below 4 4 19 Install Log 13 by placing it on the glass at the far right end of the burner as shown below 13 Final Install 12 pin landing 10 6 9 5 17...

Страница 103: ... Left Cross Log left of center 10 Right Cross Log right of center 11 Right Cross Log 2nd right from center 12 Left Cross Log far left log 13 Right end log Log Guides 3 2 lb Black Fireglass purchased separately from log set Glowing Wool supplied with unit 3 4 Crushed black glass or iceburg chips purchased separately from log set 1 Shutoffgasandelectricalsupply allowunittocooltoroomtemperature 2 Rem...

Страница 104: ...dge of the panel as shown below 11 Insert the pin of Log 6 into the hole on the right side of the pilot Posi tion the left end of Log 6 7 8 from the edge of the panel 12 Insert the pin of Log 7 into the hole on the right most side of the burner Position the left end of Log 7 1 2 from edge of panel as shown below 3 2 1 10 Insert the pin of Log 5 into the hole on the left side of the pilot Position ...

Страница 105: ...stall Log 9 line up the pin locator on Log 9 with the pin in the middle of Log 1 and rest the other end of Log 9 on Log 5 9 5 1 5 10 1 6 18 Install Log 12 with one end resting on the far left side of the burner and the other on the left end of Log 4 as shown below 4 4 19 Install Log 13 by placing it on the glass at the far right end of the burner as shown below 13 Final Install 12 Landing 10 6 9 5...

Страница 106: ...e 2 Attach the handle to the aeration lever through the access opening handle will slide into position on the lever 3 Adjust aeration accordingly Pushing lever in opens the air shutter Pulling the lever outward closes the air shutter Minimum Air Shutter Opening NG 3 16 NG with Logs 3 16 NG with Stones 3 16 LP 3 8 LP with Logs 3 8 LP with Stones 3 8 Note Any damage due to carboning resulting from i...

Страница 107: ... damaged or broken glass Replacement of the glass panels should be done by a licensed or qualified service per son Glass Replacement In the event that you break your glass by impact purchase your replacement from an authorized Regency dealer only Replacement glass is shipped alreadyinstalledintothedoorframe Reinstallasper GlassInstallationinthe GlassInstallation section REPLACEMENT GLASS CB60E 1 O...

Страница 108: ...below 4 at front and 4 at rear slide burner to the left away from the orifice and lift out 8 Remove 14 screws not shown in locations shown below 9 Disconnect the Spark Electrode flame sense stepper motor from the IFC board see wiring diagram for location 10 Lift valve tray out partially and disconnect flexible gas connection on the valve inlet side remove valve tray replace with new valve tray val...

Страница 109: ...d be checked by a licensed gas service technician during the annual service check Your unit may require more frequent maintenance checks if you notice any changes in how it operates Operational changes to look for can include but are not limited to extended start up time increased fan noise residue carbon build up white build up on the glass firebox increased operating noise etc Should any of thes...

Страница 110: ...110 City Series CB60E 1 parts list 3 1 2 4 5 6 8 7 9 13 11 10 11 12 18 17 16 21 15 14 23 24 27 26 29 28 27 25 30 22 19 20 40 5a 3a 32 33 34 35 36 37 38 39 41 43 31 42 Main Assembly ...

Страница 111: ... 30 977 167 34 911 110 Flame Electrode Spark Long 0 915 119 35 911 111 Flame Sensor Long 0 915 910 36 910 432 Novasit Pilot Tubing With Nuts 37 911 039 Two Way Pilot Hood 38 911 137 Pilot Hood Clip 39 W840470 Gasket Pilot Assembly 40 656 039 Gasket Orifice Mount 41 686 070 P Lower Glass Pad Left 42 686 071 P Lower Glass Pad Center 43 686 072 P Lower Glass Pad Right N S 686 045 Gasket Lower Pressur...

Страница 112: ...lass Barrier Adjuster Bracket CV72E N S 666 056 Glass Lift Lever CV72E N S 666 057 Glass Support Bracket CV72E N S 666 058 Firebox Glass Support CV72E N S 686 176 Restrictor CB60 Accessories Part Description N S 686 900 Steel Stud Framing Kit CB60E N S 686 906 Inner Panel Glass Black CB60E N S 686 907 Inner Panel Black CB60E N S 686 908 Inner Panel Enamel Black CB60E N S 686 927 Corner Installatio...

Страница 113: ...CRITICAL 0 000 SPECIFIED TOLERANCE 0 000 0 031 0 000 REF REFERENCE ONLY ANGULAR 1 TOLERANCES UNLESS OTHERWISE STATED DO NOT SCALE DRAWING 3RD ANGLE PROJECTION REV PART NO FIREPLACE PRODUCTS INTERNATIONAL 946 535 Flush Mount Power Vent SHEAR PUNCH FORM 8 12 2021 DATE SCALE 1 24 Power Vent End of Line Part 946 535 Part Number Description 1 911 112 P Pressure Switch Sensor includes bracket 2 911 244 ...

Страница 114: ...PECIFIED TOLERANCE 0 000 0 031 0 000 REF REFERENCE ONLY ANGULAR 1 TOLERANCES UNLESS OTHERWISE STATED DO NOT SCALE DRAWING 3RD ANGLE PROJECTION REV PART NO FIREPLACE PRODUCTS INTERNATIONAL 666 945 INLINE POWER VETN ASSEMBLY SHEAR PUNCH FORM 8 12 2021 DATE SCALE 1 8 Part Number Description 1 911 305 P 120 Volt Fan Motor 2 911 112 Vacuum Switch 3 911 047 Silicone Hose sold per foot 1 foot required 4 ...

Страница 115: ...City Series CB60E 1 115 notes ...

Страница 116: ...s Wiring Switches Blowers Blower Control Module Battery Pack Remote Control Systems 2 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crystals Firebeads Volcanic Ceramic Spa Stones 1 All hardware 1 Mesh Glass Safety Barriers 1 Accent Light Bulbs 1 Glass Crazing 1 Conditions Warranty protects against defect in manufacture or FPI factory assembled compo...

Страница 117: ...lation error installation by an unqualified installer incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels lack of regular maintenance and upkeep acts of God weather related problems from hurricanes tornados earthquakes floods lightning strikes bolts or acts of terrorism or war which result in malfunction of the appliance are ...

Страница 118: ...uld consult their local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized selling dealer is unable to provide warranty service please contact FPI by mail at the address listed below Please include a brief descrip...

Страница 119: ...s to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases made in CANADA F...

Страница 120: ...120 City Series CB60E 1 warranty ...

Страница 121: ...City Series CB60E 1 121 notes ...

Страница 122: ...122 City Series CB60E 1 notes ...

Страница 123: ......

Страница 124: ...______________________________________ Phone _____________________________________________________________ Date Installed _________________________________________________________ Serial _____________________________________________________________ Printed in Canada Regency and City Series are trademarks of FPI Fireplace Products International Ltd Copyright 2022 FPI Fireplace Products Internationa...

Отзывы: