Aeration Adjustment
The burner aeration is factory set but may need
adjusting due to either the local gas supply or
altitude. Open the air shutter for a blue flame or
close for a more yellow flame.
Minimum Air Shutter Opening:
NG 18mm
Propane Full Open
ULPG Full Open
845 S.I.T. Valve Description
1) On-Off Solenoid Valve EV1
2) On-Off Solenoid Valve EV2
3) Inlet Pressure Test Point
4) Outlet Pressure Test Point
5) Connection for Pressure Regulator/Combustion
Chamber Compensation
6) Pressure Regulator for Minimum and Maximum
Outlet Pressure
7) Gas Outlet Pressure Electric Modulator
8) Pilot Outlet
9) Main Gas Outlet
Wiring Diagram (NG Only)
Part #: 920-367
Size: (File at 100%)
Color: Black on grey
Created: 12.01.20
920-367
W
ARNING
• Disconnect power supply to unit prior to working on electrical
components.
• Ensure that the wires do not touch any hot surfaces and are away
from sharp edges.
• Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
NO
TE
• Any damage due to carboning result-
ing from improperly setting the aeration
controls is NOT covered under warranty.