Greenfire® GF1500L-2 Gas Fireplace
| 33
installation
Flueing Arrangement for Vertical Terminations - Vertical Flue with Two 90
o
Elbows (1 - 90
o
=
2 - 45
o
)
The shaded area in the diagram shows all allowable combinations
of straight vertical and offset to vertical terminations, using two
45
o
bends, with
Rigid/Flex Pipe Flueing Systems.
• Flue must be supported at offsets.
• Maintain clearances to combustibles as listed in the
"Clearances" section.
• Horizontal vent must be supported every 1M.
• Must use optional rigid pipe adaptor (Part# 770-994) when
using rigid pipe flue systems (Dura Vent Only).
• Refer to the "Flue Restrictor Position" section for details on
how to change the flue restrictor from the factory setting of
Set 0 to Set 1, Set 2 or Set 3 if required.
• Vertical flue must terminate a minimum of 600m to the
underside of the cowl from the nearest part of the roof, as
per AS/NZS 5601.
"THIS UNIT MUST ALWAYS
TERMINATE / FLUE
DIRECTLY TO THE OUTDOORS."
6.7m
4m
Restrictor Set #3
32 mm open
Restrictor Set #2
41 mm open