Greenfire® GF1500L-2 Gas Fireplace
| 29
installation
Flueing Arrangements - Horizontal Termination (Flex) - Regency
®
Direct Vent System
These flueing systems, in combination with GF1500L, have been tested and listed as a Direct Vent system by AGA. The location of the termination cap must
conform to the requirements in the Flue Terminal Locations diagram from the "Exterior Flue Termination Locations" section.
FPI Direct Vent (Flex) System Termination Kits include all the parts needed to install the GF1500L using a flexible vent.
FPI Kit #
Length Contains:
#946-615
1.2 m
1) 203mm flexible liner (Kit length)
2) 127mm flexible liner (Kit length)
3) spring spacers
4) thimble
5) AstroCap termination cap
6) screws
7) tube of Mill Pac
8) plated screws
9) S.S. screws #8 x 38mm drill point
#946-618
1.8 m
#946-616
3 m
203mm dia.
Flue pipe
127mm dia. flue pipe
spring spacer
Termination Cap
AstroCap XL
TM
(Part #946-623/P)
Flue Guard - if required*
(Part #946-506/P)
Wall Thimble
(Mandatory in all
Horizontal Terminations)
Part 946-604/P
NO
TES
• Liner sections should be continuous without any joints or seams.
• Only Flex pipe purchased from FPI may be used for Flex installations.
• Horizontal flue must be supported every 0.9m.
• A wall thimble is mandatory for all horizontal terminations due to
high temperatures.