28 |
Greenfire® GF1500L-2 Gas Fireplace
installation
Rigid Pipe Flueing Systems - Basic Horizontal & Vertical Terminations
Rigid Pipe Flue Systems offer a complete line of
component parts for installation of both horizontal
and vertical installations. Many items are offered
in decorative black, as well as galvanized finish.
The minimum components required for a basic
Horizontal Termination are:
1
AstroCap XL Termination Cap
1
90o Elbow
1
Rigid Pipe Adaptor
(Dura Vent Only)
1
Wall Thimble
1
Length of rigid pipe to suit wall thickness
The minimum components required for a basic
Vertical Termination are:
1
Vertical Termination Cap
1
Rigid Pipe Adaptor
(Dura Vent Only)
1
Lengths of pipe to adequately
penetrate roof
1
Flashing
(As required per AS/NZS
5601-2013, to be supplied by installer)
Wall thickness is measured from the back standoffs
to the inside mounting surface of termination cap. For
siding other than vinyl furring strips may be used,
instead of the vinyl siding standoff, to create a level
surface to mount the vent terminal. The Terminal
must not be recessed into wall cladding. Measure
the wall thickness including wall cladding.
When using Rigid Flue other than
Simpson Dura-Vent, 3 screws must be used
to secure rigid pipe to adaptor.
Rigid Pipe
Pipe Length
Vertical Terminal
Flashing
Pipe
Length
PipeLength
90 Elbow
o
AstroCap XL
Termination Cap
(Part#946-623/P)
Wall Thimble
(Mandatory in all
Horizontal Terminations)
(Part #946-506/P)
Flue Guard - if required
*
(Use only with Simpson Dura Vent)
-Not Supplied
Part 946-604/P
W
ARNING
• Do not combine flueing com-
ponents from different venting
systems.
• Exception: However, use of the the
AstroCap XLTM is acceptable with
all systems.