background image

      WARNING
FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly could result in serious
injury, death, or property damage. 

Installer

: Please complete the details on the back cover and leave this manual 

with the homeowner.

Homeowner:

 Please keep these instructions for future reference.

 Certified to/Certifié pour:     CSA 2.17-2017
                                             ANSI Z21.88-2019
                                             CSA 2.33-2019

Owners & 

Installation Manual

STYLE 

                          MODEL

    

See-Thru 

                          CST60E-NG / CST60E-LP                    

Tested by: 

www.regency-fire.com

 

-  Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any 

other appliance. 

- WHAT TO DO IF YOU SMELL GAS
 • 

Do not try to light any appliance.

 

•  Do not touch any electrical switch: do not use any phone in your building.

 

  Leave the building immediately.

 

•  Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's  

instructions.

 

• If you cannot reach your gas supplier, call the fire department.

 

 

- Installation and service must be performed by a qualified installer, service agency or the gas supplier.

920-348

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.  6988 Venture St., Delta, BC  Canada, V4G 1H4

09.14.21

City Series® 

CST60E DIRECT VENT 

Содержание City CST60E-LP

Страница 1: ...t store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your g...

Страница 2: ...de surface exceeds the limits specified in Clause 5 14 4 the following graphic danger and statements shall be shown on a Class IIIA 2 Permanent Label 4 34 6 Instruction Plate Each appliance shall bear a Class IIIB marking with letters on a contrasting background located adjacent to the controlling device or in an equally conspicuous position where the instruction can be easily read April 22 14 Cre...

Страница 3: ...tional Electrical Code ANSI NFPA 70 in the U S A and the current CAN CGA B149 Gas Installation Code and Canadian Electrical Code CSA C22 1 in Canada This Regency mobile manufactured home listed appliance comes factory equipped with four 1 4 6 mm diameter holes located near each corner of the base Fasten the fireplace in place using screws inserted through these holes This appliance comes equipped ...

Страница 4: ...the appliance s connected to the venting system are located and other spaces of the building 4 Close fireplace dampers 5 Turn on clothes dryers and any appliance not connected to the venting system Turn on any exhaust fans such as range hoods and bathroom exhausts so they are operating at maximum speed Do not operate a summer exhaust fan 6 Follow the lighting instructions Place the appliance being ...

Страница 5: ...allation 97 Glass Barrier Adjustment 98 Inner Black Steel Enamel Panel Installation Part 450 907 450 908 99 Inner Black Glass Panel Installation 101 Clean Trim Faceplate Installation 103 Burner and Firebox Media Options 104 Optional Driftwood Log Set Installation 106 Maintenance Instructions 114 General Vent Maintenance 114 Log Replacement 114 Glass Gasket 114 Glass 114 Glass Replacement 114 Flame...

Страница 6: ... 117 Gas Maintenance Recommended Annual Routine 118 Main Assembly 119 Accessories 121 Bottom Pressure Relief Gasket 121 Individual Glass Gasket Parts for Item 25 121 Upper Glass Clamps 122 Lower Glass Clamps 122 Power Vent End of Line Part 946 535 123 Power Vent Inline Part 666 945 124 Warranty 126 Parts Lists ...

Страница 7: ...les veuillez vous référer à la normeANSI NCSBCSA225 1 NFPA501A Cet appareil doit être utilisé uniquement avec les types de gaz indiqués sur la plaque signalétique et peut être installé dans une maison préfabriquée É U seulement ou mobile installée à demeure si les règlements locaux le permettent Voir la notice de l utilisateur pour plus de renseignements Une trousse de conversion est fournie avec ...

Страница 8: ...in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspection t...

Страница 9: ...AY BESUSCEPTIBLETOACCIDENTALCON TACT BURNS A BARRIER DESIGNED TO REDUCE THE RISK OF BURNS FROM THE HOT VIEWING GLASS IS PROVIDEDWITHTHIS APPLIANCE AND SHALL BE INSTALLED FOR THE PRO TECTION OF CHILDREN AND OTHER AT RISK INDIVIDUALS Important Message SAVE THESE INSTRUCTIONS City Line Direct Vent Fireplaces must be installed in accordance with these instructions Consult the authority having jurisdic...

Страница 10: ...l Valve As the gas control valve turns ON and OFF a dull clicking sound may be audible This is normal During the first few fires a white film may develop on the glass front as part of the curing process The glass should be cleaned after the unit has cooled down or the film will bake on and become very difficult to remove Use a non abrasive cleaner and DO NOT ATTEMPTTO CLEANTHE GLASS WHILE IT IS HO...

Страница 11: ...vice is performed you must disconnect the power and shut off gas to the appliance Diagram 1 4 The unit will turn on 5 Reset the system as follows a Turn the system off by pressing the ON OFF button on the remote b Wait 5 minutes then repeat the process from step 2 Lighting Procedure Continuous Pilot Intermittent Pilot CPI IPI selection See remote control instructions for details NOTE The first try...

Страница 12: ...nt Appelez immédiatement votre fournisseur de gaz depuis un téléphone extérieur Suivez les instructions du fournisseur Si vous ne pouvez pas rejoindre le fournisseur appelez le service incendie C N utilisez pas cet appareil s il a été plongé dans l eau même partiellement Faites inspecter l appareil par un technicien qualifié et remplacez tout élément du système de contrôle ou de commande qui a été...

Страница 13: ...tion marked The receiver will beep three times when ready to synchronize with a transmitter Install three AAA batteries in the battery bay at the base of the transmitter fig 3 Press the ON button The receiver s command is accepted and sets to the particular code of that transmitter The system is now initialized The receiver may be independent or integral to the IFC hearth appli ance control module...

Страница 14: ...il the flame is off The UP ARROW key will increase the flame height each time it is pressed If the UP ARROW key is pressed while the system is on but the flame is off the flame will come on in the high position Fig 7 8 A single beep confirms reception of the command Fig 7 Fig 8 Room Thermostat Transmitter Operation The remote control can operate as a room thermostat which can be set to a desired t...

Страница 15: ...WN ARROW keys fig 1 to turn on off or adjust to one of the fan s six speeds fig 14 A single beep confirms reception of the command Figure 13 Figure 14 Remote Dimmer Control Light The auxiliary function controls the AUX power outlet by the dimmable light control To activate this function use the MODE key fig 1 to scroll to the AUX icon fig 15 16 The intensity of the output can be adjusted through s...

Страница 16: ...e is completed The mode of the fireplace is easily changed from an intermittent pilot ignition system IPI to a continuous pilot ignition system CPI using the remote control as noted above The benefits of CPI mode are as follows Keeps venting primed for trouble free startup under colder weather conditions or inversions Keeps the unit glass warm which decreases the amount of condensa tion on startup...

Страница 17: ...ifting or floating If there is a problem call a qualified service person 5 The appliance and venting system must be inspected before use and at least annually by a qualified field service person to ensure that the flow of combustion and ventilation air is not obstructed 6 Do not use this appliance if any part has been underwater Immediatelycallaqualifiedservice techniciantoinspecttheapplianceand r...

Страница 18: ...G H I J L M N A K O B C D E F G H I J L M N A K O Dimensions Item Description Measurement A Exhaust center to stand off 12 11 16 323 mm B Unit body depth 22 3 16 564 mm C Width lip to lip 23 1 4 591 mm D nailing strip 79 1 13 2009 mm E Glass center to standoff 32 13 16 833 mm F Glass center to standoff 38 7 8 987 mm G Gas connection N A H Aeration adjustment N A Item Description Measurement I Elec...

Страница 19: ... mm E 7 3 16 199 mm F 4 5 16 109 mm G 28 1 8 715 mm H 12 3 4 323 mm I 24 9 16 624 mm J 11 1 8 282 mm A 1 1 2 38 mm B 1 2 13 mm Side B Side A K 3 1 6 77 mm L 11 knockouts total each 2 51 mm x 13 11 16 352 mm E F Metal box supplied for all 120 volt connections A B C D A B C D Side A Side B Side B C 1 25 mm D 3 3 4 95 mm E 4 3 4 121 mm F 2 1 2 64 mm Gas Connection Electrical Connection Side A Side B ...

Страница 20: ...Codes 2 See general installation and assembly instructions The appliance and vent should be enclosed 3 This appliance must be connected to the specified vent and termination cap outside of the building envelope Never vent to another room or the inside of a building Make sure that the vent is fitted as per venting instructions 4 Inspect the venting system annually for blockages and any signs of det...

Страница 21: ...other combustible material other than wood flooring the appliance must be installed on a metal or wood panel extending the full width and depth of the appliance 4 This Direct Vent Gas Fireplace can be installed as follows Position Model A B CST60E See through 5 This appliance is listed for bedroom installations when used with a listed millivolt thermostat Some locations may have further requiremen...

Страница 22: ... are removed that the screws are put back into place in all 12 holes locations where the handle had been previously 6 per side The handles can be recycled tooltip Remove the screws securing the unit to the pallet Due to the CST60E s size and weight 556 pounds 252 kg shipping weight lifting and moving the unit requires 4 people Placea2x4longenoughtoprovideasolidgriponeachsideundereachhandle Lift an...

Страница 23: ...re reinstalled prior to any finishing See locations in the diagram to the right 1 Identifytheaccesspanelandremovethecorrespondingouter trimpanelbyliftingitupandoff centrepanelshownopposite 2 From inside the unit push in the tab to release the access panel at the top 3 Push the access panel toward the inside of the unit and lift up from the bottom to release the bottom tabs When clear lift out of u...

Страница 24: ...when installing into an exterior cavity or alcove enclosure ceiling back and sides re gardless of where the appliance is placed within the home drywall or other materials such as plywood wood studs etc are required to prevent heat from escaping above or through the enclosure other than out the required grill ventilation openings Internal chase when installing as an internal chase framing regardles...

Страница 25: ...ee mantel clearances chart in the manual A minimum of 120 square inches of open area not lower than 0 2 from top of enclosure is required for all installations NOTES Flush installation is when the chase enclosure height is at a minimum of 81 1 4 2064 mm or greater This would be a typical installation with walls placed between two rooms to divide them The clearances listed below are minimum require...

Страница 26: ...entilation opening Mesh screen louvers or other protection should be used If the ventilation openings are placed in two rooms two different pressure zones the ventilation openings must have equally split air openings to balance air flow A B D C A 10 154 mm min B 2 51 mm max C 120 sq in min D 1 1 2 38 mm min Option 2 Front Side Shown with ventilation openings on side and front to meet the minimum r...

Страница 27: ... of 120 sq in When ventilation openings are on both sides with the second open ing in another room two different pressure zones ventilation openings must be the same size to balance air flow A B C D Option 4 One Side A 2 51 mm max B 120 sq in min C 4 102 mm min D 10 254 mm min Shown with ventilation opening on one side to meet the minimum requirement of 120 sq in A B C D 2nd ventilation opening in...

Страница 28: ... with ventilation opening at top of enclosure to meet the minimum requirement of 120 sq in A minimum gap of 1 3 4 44 mm between the top of the enclosure and the ceiling is required with this type of ventilation opening to equal the minimum requirement of 120 sq in Ceiling Ventilation Opening ...

Страница 29: ...The size of the ventilation opening is reduced from 180 sq in to 120 sq in The clearances listed below are minimum requirements for either side of this see through fireplace unless otherwise noted A major cause of chimney related fires is failure to maintain required clearances air space to combustible materials It is of the greatest importance that this fireplace and vent system are installed in ...

Страница 30: ...thrown into it Mesh screen louvers or other protection should be used If the ventilation openings are placed in two rooms two different pressure zones the ventilation openings must have equally split air openings to balance air flow A B C D A 10 254 mm min B 180 sq in min C 1 1 2 38mm min D 3 77 mm min A B C D Option 2 Front and Back Shown with ventilation openings on the front and back of the enc...

Страница 31: ...Front Back Wall with second ventilation in separate room Shown with ventilation opening on front and back to meet the minimum requirement of 180 sq in When on the front and back with second ventilation located in another room two different pressure zones ventilation openings must be the same size and have equally split air openings to balance air flow A B C D A 10 51 mm min B 2 51 mm max C 90 sq i...

Страница 32: ...ng on the front to meet the minimum require ment of 180 sq in A B C D A 10 254 mm min B 2 51 mm min C 180 sq in min D 1 1 2 38 mm min A 10 254 mm min B 2 51 mm min C 180 sq in min D 1 1 2 38 mm min Chimney Chase Firestop required at top of bench enclosure IMPORTANT The chimney chase must be sealed with a firestop to prevent heat from escaping into the chimney chase enclosure All heat must exit thr...

Страница 33: ...f front facing are shown in the diagram below 2 12 6 4 8 10 0 14 B 10 20 26 A F C 0 0 10 20 26 0 2 4 6 8 10 12 14 E D B C D E A B C D E F F A A 12 305 mm maximum B 9 229 mm C 5 1 4 133 mm maximum D 18 1 16 459 mm E 10 1 4 260 mm from base of unit to bottom of fireplace F 1 2 Drywall wood wood panel etc ...

Страница 34: ...el leg clearances as per diagram A A B C D E F F E D C B H H G A Mantel Leg B Allowable mantel leg projection C 12 305 mm D 9 229 mm E 7 179 mm F 5 127 mm G 60 5 16 1532 mm measured from side lip finishing H 10 1 4 260 mm NOTE One side shown Clearances are the same on the other side ...

Страница 35: ...can be removed prior to installation If the framing is raised off the ground you can install it after the appliance is in place with handles removed to maintain the framing width of 71 3 4 1822 mm Ensure that the wood base for the appliance is strong enough to support its shipping weight of 556 pounds 252 kg B A D C E NOTESS Framing may be constructed of combustible material i e 2 x 4 or 2 x 6 and...

Страница 36: ... 2 or less from the top of the chase enclosure Max 2 51 mm Ceiling Ceiling Top of chase enclosure Max 2 51 mm Stud Stud Stud Stud 60 1524 mm Chase Vent Finishing material Finishing material Opening for vent 3 3 5 Min 60 25 60 1524 mm Chase Vent Chase Vent Installation White Front Part 686 991 A 60 1 2 1537 mm B Opening for vent 3 1 4 83 mm 3 1 2 89 mm B A NOTE This chase vent is only used when acc...

Страница 37: ...er placement of the fireplace in the surrounding materials Wall board materials 1 2 in 13 mm thick are specified in this manual to align with the optional finishing methods offered with this appliance The CST60E may be finished to the appliance opening with 1 2 inch 13 mm thick drywall Ensure that the back and side clearances are maintained No screw zones in shaded areas as shown below must be adh...

Страница 38: ... the fireplace itself 3 One of the following methods must be used to prevent heat from escaping into the cavity of the enclosure a If choosing drywall joints MUST be sealed using drywall tape and mud b Insulation plywood wood studs etc must be installed tightly with no gaps or seams This appliance was designed with hot air escaping through the chase en closure ventilation grills only If hot air is...

Страница 39: ...ight requirements D Screws must not penetrate unit more than 1 2 25 mm Adhere to No Screw zones painted on unit glue is an ac ceptable alternative E Min 16 1 2 419 mm with 2 x 4 dimension C Min 23 3 8 594 mm with 2 x 6 diemnsion C F Maximum 5 1 4 133 mm G Bottom of fireplace opening combustible hearth shown NOTE A recess may be used on both sides if the clearance require ments shown above are adhe...

Страница 40: ... is an ac ceptable alternative E Min 16 1 2 419 mm with 2 x 4 dimension C Min 23 3 8 594 mm with 2 x 6 dimension C F 5 1 4 140 mm maximum G Bottom of fireplace opening combustible hearth shown Typical Installations Recessed TV Install NOTE A recess may be used on both sides if the clearance require ments shown above are adhered to The TV mounting bracket cannot be secured directly to the appliance...

Страница 41: ...top surface Recess Install Example Flush Install Example Finish up to trim on all 4 sides Loosen screws using supplied Offset Screwdriver and remove bottom and side trim pieces Front edge of side liner panels must not be covered by finishing material or removal of the Firebox Glass will not be possible Bottom edge should be flush with top surface of Inner Liner Panel ...

Страница 42: ...ider into the cover plate 7 Put the battery holder switch in the OFF position to allow correct lineup for slider switch 8 Make sure the battery holder and cover plate words ON and UP are on the same side 9 Align the slider with the switch on the battery holder and couple the switch into the slider 10 Align the screw holes 11 Using the two 2 screws provided secure the cover plate to the battery hol...

Страница 43: ...or using the 2x M4 x 7 screws supplied Tighten the screws to 25lb in In the event that the screw threads are cross threaded or stripped replace the valve as sembly Install the enclosed propane identification label to the valve body where it is easily seen Pressure regulator screws 9 Re attach the pressure regulator wire disconnected in step 6 re situate the IFC and secure the screws that fasten th...

Страница 44: ...ten Burner Orifice Location 12 Loosen 8 screws in the locations shown below 4 at front and 4 at rear slide the burner to the left away from the orifice and lift it out Slide burner to the left and lift out City Series LP SYSTEM DATA Min Supply Pressure 11 WC 2 73kpa Manifold Pressure High 10 5 WC 2 62 kpa Manifold Pressure Low 2 9 WC 0 72 kpa Orifice Size 50 DMS Maximum Input 36 000 Btu h 10 54 kW...

Страница 45: ...inimum Input 19 500 Btu h 5 71 KW Incorrect flame pattern will have small probably yellow flames not coming into proper contact with the rear burner or flame sensor Pilot Adjustment Periodically check the pilot flames Correct flame patternhastwostrongblueflames 1flowingaround the flame sensor and 1 flowing across the burner it does not have to touch the burner 885 S I T Valve Description 1 6 Stage...

Страница 46: ...d above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 30cm 9 23cm L Clearance to a mechanical air supply inlet 3 91cm above if within 10 3m horizontally 72 1 8m 36 90cm b M Clearance above paved sidewalk or a paved driveway located on public pro...

Страница 47: ...8DVA ES 5DT OS N A TM 5OS N A Wall Thimble Black 58DVA WT 5DT WT 5DWT N A VDV WPT05 Wall Thimble Support Ceiling Support 58DVA DC N A N A N A N A Firestop Spacer 58DVA FS 5DT FS 5DFS TM 5LS VDV FS05 Trim Plate Black 58DAV WFS 5DT TP 5DCP TM 5TP VDV WTC05 5 X 8 RIGID PIPE CROSS REFERENCE CHART Components from different Manufacturers may not be mixed Not all rigid pipe components are available direc...

Страница 48: ...rigid piping 946 506 P Vent Guard Optional 946 606 Starter collar reducer 5 x 8 to 4 x 6 5 8 B36XTE B36XTCE ONLY 946 625 Vinyl Siding Standoff AstroCap XL Note When using Metal Fab Sure Seal Rigid Piping please note that the Adaptor 5DDA must be used in conjunction with FPI Rigid Pipe Adaptor 770 994 Not available applicable for the following units B41XTE B41XTCE CB60E CV60E CV72E HZ54E U1500E Off...

Страница 49: ... as indicated in the venting arrangements diagrams refer to the following instructions 1 Remove the safety barrier glass and firebox glass see instructions in this manual 2 Adjust the vent restrictor plate to the required vent restrictor position as per the diagrams shown 3 Once the vent restrictor plate is in the required position secure with screws Vent Restrictor Position A Set 0 Fully open Fac...

Страница 50: ... than the specified minimum or as per local codes VENT RESTRICTOR SETTING Vent restrictor factory set at Set 0 Refer to the Vent Restrictor Position section for details on how to change the vent restrictor from the factory setting of Set 0 to Set 2 if required 46 1 4 1175 mm Minimum Height Requirement Vent Restrictor Set 3 2 3 8 Open Vent Restrictor Set 2 3 1 8 Open Set 0 Fully Open Factory Set Th...

Страница 51: ...parts needed to install the CST60E using a flexible vent FPI Kit Length Contains 946 615 4 Feet 1 8 Flexible Liner Kit length 2 5 Flexible Liner Kit length 3 Spring Spacers 4 Thimble 5 AstroCap XL Termination Cap 6 Screws 7 Tube of Mill Pac 8 Plated Screws 9 S S Screws 8 x 1 1 2 Drill Point 10 Vinyl Siding Standoff 946 618 6 Feet 946 616 10 Feet NOTES Liner sections should be continuous without an...

Страница 52: ...mm 11 1 2 292 mm 12 305 mm 9 229 mm 14 1 2 368 mm 11 279 mm 14 5 8 371 mm adj pipe 15 381 mm 23 1 2 597 mm 17 432 mm 24 610 mm adj pipe Adj Pipe Length Horizontal Termination Cap Wall Thimble Vinyl Siding Standoff Optional Rigid Pipe Adapter o 90 Elbow Pipe Length This product was evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with Duravent Direct Vent Selkirk Direct Temp Amer...

Страница 53: ...venting must be used Horizontal Venting with Two 90o Elbows One 90o elbow two 45o elbows Option V min H H1 max With these options maximum total pipe length is 30 feet 9 1 m with minimum of 6 feet 1 8 m total vertical pipe and maximum 8 feet 2 4 m total horizontal pipe A minimum of 1 ft 610 mm is required between all 900 elbows A 3 914 mm 4 1 2 m B 4 1 2 m 5 1 5 m C 5 1 5 m 6 1 8 m D 6 1 8 m 8 2 4 ...

Страница 54: ... level and whenever passing through a wall Must use optional rigid pipe adaptor Part 770 994 when using rigid pipe vent systems Refer to the Vent Restrictor Position section for details on how to change the vent restrictor from the factory setting of Set 0 through to Set 5 if required For vertical terminations the Regency DirectVent Flex System may be used for installations with a maximum vent len...

Страница 55: ...to 10 12 2 1 2 0 76 over 10 12 to 11 12 3 1 4 1 over 11 12 to 12 12 4 1 2 over 12 12 to 14 12 5 1 5 over 14 12 to 16 12 6 1 8 over 16 12 to 18 12 7 2 1 over 18 12 to 20 12 7 1 2 2 3 over 20 12 to 21 12 8 2 4 This product was evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with Duravent Direct Vent Selkirk Direct Temp AmeriVent DirectVenting ICC Excel Direct Olympia Ventis DV an...

Страница 56: ...ree 3 90o Elbows One 90o elbow Two 45o elbows V H1 H V1 Option V min H H1 max V V1 min A 1 305 mm 2 610 mm 3 0 9 m Min B 2 610 mm 3 0 9 m 4 1 2 m Min C 3 0 9 m 4 1 2 m 6 1 8 m Min D 4 1 2 m 5 1 5 m 7 2 1 m Min E 5 1 5 m 6 1 8 m 8 2 4 m Min F 6 1 8 m 7 2 1 m 9 2 7 m Min G 7 2 1 m 8 2 4 m 10 3 m Min Lengths do not include elbow indicated Restrictor Set 0 Factory Setting NOTES For horizontal terminat...

Страница 57: ...inner pipe over the flex to rigid adaptor and secure with 3 screws 12 Repeat Step 11 to secure outer flex 3 Cut a hole in the roof centered on the small hole placed in the roof in the previous steps The hole should be a minimum of 11 279 mm The hole may be round and or square 4 Slip the flashing under the shingles and line up flashing so it is centered to the hole shingles should overlap half of t...

Страница 58: ...eparately See Simpson Duravent components list in the instruction manual for part numbers Flex Pipe Ceiling Firestop Roof Support Brace Flashing Storm Collar Termination Cap Ceiling Firestop Enclosure Flex Pipe Ceiling Firestop Roof Support Flashing Elbow Support Termination Cap Storm Collar Ceiling Firestop Support to prevent sagging Enclosure Ceiling firestop Flashing Termination Cap Storm Colla...

Страница 59: ... pipe from the Vertical termination kit over the flex adapter ensuring that the inner flex pipe overlaps the collar by at least 1 4 35 mm Fasten with 3 screws 4 Apply a bead of Mill Pac around the perimeter of the 8 203 mm outer collar of the flue adapter and slip it over the 8 203 mm outer flex pipe from the vertical termination kit ensuring that the outer flex pipe overlaps the collar by at leas...

Страница 60: ...P SPACER PART 946 757 Used in conjunction with the 946 755 Vertical flex kit and 946 756 kit Vertical flex extension kit Horizontal power vent kit Firestop spacer to prevent debris from falling into the ceiling firestop Aceiling firestop firestop spacer must be installed when passing through each floor orceiling level Toinstall theceilingfirestop firestop spacer in a flatceiling or floor joist cut...

Страница 61: ...ppliance by a licensed electrician Do not cut the ground terminal off under any circumstances Item Part Description 1 911 280 Pilot Assembly NG 911 280 Pilot Assembly LP W84470 Pilot Gasket not shown 2 911 110 Spark Electrode 3 911 111 Flame Sensor Electrode 4 911 311 PFII IFC Board 5 N A Green to Ground 6 911 344 Power Harness w Aux Connector 7 911 253 ASM Main Line 8 911 272 Variable Lights Item...

Страница 62: ... Supply The wiring for the unit should be completed before any finishing material is installed 1 Remove the right access panel see access panel removal instructions in this manual 2 Loosen 2 screws in locations shown below A DETAIL A SCALE 1 6 B DETAIL B SCALE 1 4 C 3 Slide electrical box plate towards the back of the unit and then out Side A Side A Side A ...

Страница 63: ...led 6 Feed any excess wiring into the wall and reinstall the plate onto the wall of the unit 7 Reinstall electrical box and plate onto screws 8 Tighten screws to secure Receptacle cover Receptacle 8 Tighten screws to secure 4 Bring the wiring from inside the wall through the opening created when the plate was removed in the previous step 5 Wire the electrical box NOTE The receptacle and receptacle...

Страница 64: ...refully prior to installation of this appliance 120 Volt AC power is required for this appliance to operate A receptacle box receptacle and cover are provided See the Wiring the Unit section in this manual Electrical power must be brought to the appliance by a licensed electrician NOTES Rigid pipe is approved for up to 72 feet 21 95 m Flex pipe is approved for up to 40 feet 12 19 m using 2 X 946 7...

Страница 65: ...e Length 7 Black N A N A 4D7AB N A N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A N A N A N A N A N A Extension Pipe 8 1 2 Black 46DVA 08AB N A N A N A N A N A N A Adjustable Length 12 Galvanized N A N A 4D12A N A SV4LA12 TC 4dLSI N A Adjustable Length 12 Black N A N A 4D12A N A SV4LBA12 TC 4dLSIB N A Extension Pipe 16 Galvanized 46DVA 16A N A N A N A N A N A N A Extension Pipe 16 Black...

Страница 66: ...old Climates 36 N A N A 4DAIS12 N A N A TM 4AS N A Wall Firestop 46DVA WFS N A N A N A N A TM 4TR VDV FS04 Offset Pipe Selection Use this table to determine offset pipe lengths Pipe Length L 4 x 6 5 8 Venting For specific instructions on venting components visit the manufacturers website listed below Run X Rise Y 0 0mm 4 7 8 124mm 13 7 8 340mm Simpson Direct Vent Pro www duravent com 6 152mm 8 203...

Страница 67: ... Inline power vent location restrictions Minimum 4 ft 1 2 m from the unit Minimum 1 ft 0 3 m prior to an elbow Minimum 1 ft 0 3 m following an elbow Minimum 1 ft 0 3 m prior to a termination cap When the inline blower is installed after a negative run for every foot of negative run the inline blower must be an equal distance or greater from the 90 degree elbow See example above IMPORTANT Maximum t...

Страница 68: ...ith a 5 127 mm inner and an 8 203 mm outer collar which must be reduced to 4 x 6 5 8 102 mm x 168 mm in all applications mes with a 5 127 mm inner and an 8 203 mm outer collar which must be reduced to 4 x 6 5 8 102 mm x 168 mm in all applications Must be terminated horizontally Vertical ter Must be terminated horizontally Vertical terminations are not permitted minations are not permitted RIGID PI...

Страница 69: ...6 523 P Wall Thimble Adaptor Pipe Part 946 219 P Maximum 2 20 6 10 m long liners 6 5 8 152 mm Dia Flue Pipe 4 102 mm Dia Flue Pipe Power Vent Terminal Part 666 945 NOTES Only flex pipe purchased from Regency may be Only flex pipe purchased from Regency may be used for Flex installations used for Flex installations Horizo Horizontal vent must be supported every 3 feet ntal vent must be supported ev...

Страница 70: ... 90 27 43 m 5 Wire BX Cable Sold separately Amount required for install 4 x 6 5 8 102 mm x 168 mm Rigid Pipe Sold separately 1 666 945 Power Vent Kit Sold separately 1 946 206 Vinyl Siding Standoff Sold separately 1 946 523 P Astro Cap Termination Sold separately 1 Wall Thimble Sold separately 1 946 506 P Vent Guard Sold separately NOTE Slip section is mandatory Inline power vent location restrict...

Страница 71: ...Installation Wall Thickness inches Vent Length Required inches 4 5 1 2 6 7 8 1 2 9 10 11 1 2 12 9 14 1 2 11 14 5 8 Adj Pipe 15 23 1 2 17 24 Adj Pipe Adj Pipe Length Rigid Pipe Adapter Part 770 994 o 90 Elbow Pipe Length Vent reducer Part 946 606 Power Vent Trim Power Vent Terminal Frame Assembly Power Vent Frame Power Vent Kit Part 946 535 Table 1 Power Vent Kit with Vent Terminal 1 770 994 Rigid ...

Страница 72: ...this system 946 535 Power Vent Kit with Vent Terminal 1 946 758 Reducer required Sold separately 2 Max 946 756 20 Flex Kit Sold separately 1 Power Vent Fan Included w Power Vent kit 1 Power Vent Frame Included w Power Vent kit 1 911 250 P 45 5 Wire BX Cable or Sold separately 1 911 251 P 90 5 Wire BX Cable Sold separately 1 946 535 Power Vent Kit Sold separately Models Equipped with Surefire Ignit...

Страница 73: ...ming using nails or screws through the top and side nailing strips Diagram 1 Diagram 2 6 Mark the wall for a square hole see chart on this page for size The center of the square hole shouldlineupwiththecenterlineofthehorizontal pipe Cut and frame the square hole in the exterior wall where the vent will be terminated See diagram 2 for center line requirements If the wall being penetrated is constru...

Страница 74: ...ent location restrictions Minimum 4 ft 1 2 m from the unit Minimum 1 ft 0 3 m prior to an elbow Minimum 1 ft 0 3 m following an elbow Minimum 2 ft 0 6 m prior to a termination cap Minimum 2 ft from inline PV to termination cap Minimum 4 from top of unit to inline PV Max of 72 22 m using up to six 900 elbows Example shows two 900 elbows No negative runs 61 m from inline ermination cap 22 m from to ...

Страница 75: ...e increased A poor draft or down drafting can result from high wind conditions near big trees or adjoining roof lines in these cases increasing the vent height may solve the problem Roof Pitch Minimum Vent Height Feet Meters flat to 7 12 2 0 6 over 7 12 to 8 12 2 0 6 over 8 12 to 9 12 2 0 6 over 9 12 to 10 12 2 1 2 0 8 over 10 12 to 11 12 3 1 4 1 over 11 12 to 12 12 4 1 2 over 12 12 to 14 12 5 1 5...

Страница 76: ...nd whenever passing through a wall Must use optional rigid pipe adaptor part 510 994 when using rigid pipe vent systems Vertical Venting with Three 3 90o Elbows One 90o elbow Two 45o elbows V H1 H V1 Option V H H1 V V1 With these options max totalpipelength is 30 feet with min of 10 feet total vertical pipe and max 8 feet total horizontal pipe Please note min 1 foot between 90o elbows is required ...

Страница 77: ...ncludes 20ft 6 10m flex pipe with 10 spacers inner outer pipe 3 wall straps ceiling firestop roof brace flex to rigid adaptor roof support brace 36 in 914 mm rigid Duravent pipe storm collar high wind termination cap hardware 1 Max 946 756 20 6 1 m flex kit extension sold separately 1 946 758 Reducer required sold separately 1 Power vent fan included w power vent kit 1 911 250 P 45 13 7 m 5 wire B...

Страница 78: ... 24 3 16 614 mm B 16 1 16 406 mm C 14 1 4 362 mm D 4 3 8 111 mm E 11 11 16 297 mm F 15 5 8 397 mm G 17 1 16 433 mm H 10 254 mm I 11 279 mm J 5 7 8 149 mm K 4 7 16 113 mm L 6 7 16 163 mm M 3 1 4 62 mm N 4 1 2 114 mm O 12 1 4 312 mm P 14 1 4 362 mm A B C D E F G H I J K L M N O P ...

Страница 79: ...ally Pressure switch orientation if inline power vent is oriented vertically see Diagram 1 Pressure switch orientation if inline power vent is oriented horizontally see Diagram 2 Gas Power Vent Installation Framing Inline Power Vent Terminations Termination End Directional Arrows Termination End Appliance End Appliance End Vent at appliance end Vent at appliance end NOTE The inline power vent will...

Страница 80: ...ine up the holes and screw the bracket back onto the mount Pressure switch side P Pressure switch side V Pressure switch installed Power Vent Terminal Installation Fan Part 911 305 IMPORTANT Pressure switch Part 911 112 must always be oriented vertically inside the inline power vent Pressure switch Part 911 112 must always be oriented vertically inside the inline power vent The longer silicone tub...

Страница 81: ... 305 mm 16 in 406 mm 2 in 51 mm 2 in 51 mm 3 in 76 mm Gas Power Vent Installation Clearance Requirements Inline Power Vent Terminations 920 210b 09 22 20 10 CV72EPV CB72EPV CB40EPV CC40EPV CV40EPV CV60EPV Inline Power Vent Vertical or Hortizontal Installation Instructions Confined spaces chase closet attic behind a wall 3 76 mm clearance is required on top of the power vent in a horizontal configu...

Страница 82: ...chart to left for size The center of the square hole should line up with the centerline of the horizontal pipe Cutandframethesquareholeintheexteriorwall where the vent will be terminated See diagram 2 for centerline requirements 5 Assemble the desired combination of pipe and elbows to the appliance adaptor and twist lock for a solid connection Recommended Framed Opening Size Vent Size Framing Size...

Страница 83: ...fire place a minimum of 1 3 8 38 mm You may wish to cut the liner shorter to make it more workable Do not bend the liner more than 90 7 Apply Mill Pac over the fireplace inner flue collar and slip the inner flex liner down over it Attach with three supplied screws 8 Do the same with the outer flue collar and outer flex liner 9 Apply a bead of silicone between the thimble and termination and around...

Страница 84: ...be sized to meet the minimum requirement of 1 1 2 38 mm clearance to combustibles Slip the flashing under the shingles as per Diagram 4 shingles should overlap half of the flashing Offset Chart A poor draft or down drafting can result from high wind conditions near big trees or adjoining roof lines Increasing the vent height may solve this problem 7 Ensure vent is vertical and secure the base of t...

Страница 85: ... support Ceiling firestop Firestopspacertopreventdebrisfrom falling into the ceiling firestop 5 A ceiling firestop firestop spacer must be installed when passing through each floor or ceiling level To install the ceiling firestop firestop spacer in a flat ceiling or floor joist cut a 10 inch square hole Frame the hole as show in Diagram 2 and install the ceiling firestop Slide the top attic insula...

Страница 86: ...ength of pipe is a minimum of 2 feet 610 mm measured from the top of the roof Level the chimney and secure it to the bottom side of the roof using the roof support provided with the kit and a minimum of 2 screws per side see Diagram 3b See Diagram 4 for roof pitch and height requirements See Diagram 3a for securing method If 2 ft 610 mm is insufficient and additional lengths are required these may...

Страница 87: ...ery 3 feet to avoid excessive stress and sagging of the vent pipe Wall straps are provided 3 in total for this purpose Round plumbersstrappingmaybeusediffurthersupportsarerequired NOTE Theinnerandouterpipesmaybecutifonlyashortlengthisrequired 2 Install spring spacers around 4 100 mm inner pipe as shown Slide outer flex pipe over and all the way down the 4 pipe 3 Apply a bead of Mill Pac around the...

Страница 88: ...68 mm Part 946 758 919 698 06 12 18 60 1 4 Ceiling firestop Diagram 1 Diagram 1a Enclosure Ceiling firestop Flashing Termination Cap Storm Collar Roof support Ceiling firestop Firestop spacer to prevent debris from falling into the ceiling firestop CEILING FIRESTOP FIRESTOP SPACER PART 946 757 Used in conjunction with the 946 755 Vertical Flex Kit and 946 756 Vertical Flex Extension Kit Horizontal ...

Страница 89: ...tie 8 Reinstall cover plate with 4 screws Zip tie 5 Connect ground wire to ground lug located on the side wall of the power vent box Gas Power Vent Installation Wiring the Inline Power Vent to the Unit Blue to Blue Black to White NOTE Pressure switch must always be oriented vertically Pressure switch must always be oriented vertically inside the inline inside the inline power vent power vent NOTES...

Страница 90: ...shing and the vent Determine protrusion Determine finishing Set frame depth starting 2 of faceplate protrusion material thickness of faceplate 2 Run the venting and BX cable from the unit to the framed opening 3 Installthestrainrelief supplied tothebackofthepowerventmountbox 4 Strip the sheath from the BX cable to expose approximately 8 203 mm of exposed wires 5 Feed the BX cable through the strain...

Страница 91: ...ith supplied marrette Red Wire Ground Blue Wire Grommet in bracket Grommet in bracket Red to Red Black to Black Black to White 17 Connect remaining wires from the power vent motor to the BX cable black to black and black to white Cap paired wires with supplied marrette 18 Reinstall rain guard and tighten screws 19 Reinstall front faceplate with 4 screws NOTES Cut off existing connectors from fan m...

Страница 92: ... to junction box Diagram 3 5 Strip 24 of BX exposing wires then run BX through strain relief on right side of the unit into the junction box Diagrams 4 5 Remove 1 Screw Strain relief Diagram 1 Single sided model shown Diagram 5 Diagram 2 Diagram 3 Diagram 4 Remove Access Panel 3 Locate the white and black power cables Cut the connectors off and strip the wires 4 Locate the red and blue cables Remo...

Страница 93: ...panels removed in Step 1 Diagram 9 Ground from BX 8 After the power and pressure switches have been connected place wired connections into junction box and screw the junction cover plate back in place 9 To make the ground connection release the front right glass gasket pad by turning clips 3 total counter clockwise Diagram 8 Glass gasket pad Diagram 8 7 Join the Pressure switch and BX cable wires ...

Страница 94: ...attery Holder 26 911 181 Battery Connection 27 911 193 Connector w Jumper 1 2 3 4 5 9 7 6 8 10 11 12 13 17 16 24 25 20 While the burner does not require a 120 V A C power supply it is highly recommended as a primary power source Batteries 4 AA should be used as a secondary power source only CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and ...

Страница 95: ...uter safety barrier glass panels if previously installed see instruc tions in this manual 2 Removeouterpanelsinstalledinunit seepanelremovalsectioninthismanual 3 From the front inside lower panel of the unit pivot the glass support into upright position as shown below WARNING GLASS HANDLING We recommend using the glass vacuum holders supplied by the manufac turer Lowertheglasstorestinasafeplace th...

Страница 96: ...e glass 7 Locate the 2 levers below the glass and turn them both 90 in a clockwise direction to lower the firebox glass panel 8 Carefully lean glass forward onto support Glass panel leaning on support Lower clamps x9 in open position Push down on levers to lower glass panel Gasket pad NOTE The firebox glass may remain propped on the glass supports to clean the interior surface Use care when cleani...

Страница 97: ...the vacuum clamps to the glass as shown on the outer surface Press the vacuum clamps against the glass then close the clamps while maintaining pressure on the glass 4 Slide the corner protectors onto the bottom corners of the glass 5 Holding the glass barrier in front of the unit slide it up behind the top lip of the unit Lift the barrier up as far as it goes then hook the barrier onto the unit 6 ...

Страница 98: ...nt Glass barrier adjustment If glass isn t hanging straight use a phillips screwdriver to adjust the angle Clockwise angles barrier out toward you Counter clockwise angles barrier in towards the unit Slide the screwdriver straight up at the two indicator slots Glass Barrier Adjustment ...

Страница 99: ...284 mm 4 x 2 17 11 16 449 mm x 11 3 16 284 mm 5 x 4 17 7 8 454 mm x 5 127 mm 3 Drop the six 3 inner panels into the firebox then drop the two 2 side covers as shown below Sheet metal components may have sharp edges Please handle with care The enamel panels require an insulation panel installed behind them Failure to do so may result in an elevated operating temperature and premature failure of the...

Страница 100: ...s between the wall and the barrier stopper bracket Repeat steps to install the remaining three 5 outer panels using a barrier stop where required F DETAIL F SCALE 1 8 F DETAIL F SCALE 1 8 F DETAIL F SCALE 1 8 F DETAIL F SCALE 1 8 9 Clean the outer panels with a cloth before installing the safety outer barrier glass To install the safety glass see this manual for instructions ...

Страница 101: ...s to unit and allow to cool to room tempera ture Remove the safety glass and firebox glass at one side only whichever is accessible see manual for instructions Note The screws to secure all clips mentioned in these instructions are on the appliance already Simply remove and reinstall 2 Identify panels and order of installation D DETAIL D SCALE 1 4 6 Slide the side glass panel 4 into the bottom sid...

Страница 102: ...s between the wall and the barrier stopper bracket If the unit does not have a barrier stopper stick the side outer panels to the magnets Repeat steps for the remaining 3 outer sides G DETAIL G SCALE 1 8 12 Clean the outer panels with a cloth before installing the safety outer barrier glass To install the safety glass see this manual for instructions 9 Install the 6 5 outer front panels 3 5panelsp...

Страница 103: ... plates from right and left sides 4 Hand bend attachment tabs so they bend past the magnets to the mounting bracket 5 Affix clean trim faceplate with self tapping scews included in the box 1 Frame in fireplace and install finishing material Clean trim face plate can accommodate finishing materials of 1 2 13 mm to 1 1 8 29 mm 3 Insert clean trim faceplate into fireplace opening Clean Trim Faceplate...

Страница 104: ...one river pebbles firebeads and 3 4 crushed glass around the burner only Media not supplied with unit must be purchased separately Media should only cover up to a maximum of 50 of the burner surround Adriron Embers Fireglass Black Coal Crushed Glass Fireglass Lava Embers Fireglass NOTE Regardless of options chosen fireglass must be installed on the burner in all cases IMPORTANT Use supplied approv...

Страница 105: ...City Series CST60E 105 installation media Firebeads Fireglass Spa Stones Fireglass Crushed Glass Iceburg Chips Fireglass River Stones and Fireglass Volcanic Ivory Tan Basalt Natural Stones Fireglass ...

Страница 106: ...er appears on its underside 2 2 lb Black Fireglass purchased separately from log set 3 Glowing Wool supplied with unit 4 3 4 Crushed black glass or iceburg chips purchased separately from log set or Andriron embers Volcanic stones cannot be used with the driftwood log set 1 Shut off the gas and electrical supply and allow the unit to cool to room temperature 2 Remove the barrier glass if already i...

Страница 107: ...bottom left end of the log is 3 4 away from the edge of the firebox 5 Install black fireglass 2lb and glowing wool on the burner as shown below 6 Locate the hole on the burner surround on the left side of the pilot Insert the pin underneath Log 1 into the hole on the burner surround 2 CITY SERIES 60 ...

Страница 108: ... pin of Log 2 into the hole Lay the log on the firebox then measure the edge of the log to the side as shown below 10 Connect the hole underneath Log 3 to the pin on Log 1 Rest Log 3 on the landing on Log 1 8 Locate the hole on the right side of the pilot 3 CITY SERIES 60 ...

Страница 109: ...lation media 920 393 07 14 21 12 Connect the hole underneath Log 5 to the pin on Log 2 Rest Log 5 on the landing on Log 2 11 Connect the hole underneath Log 4 to the pin on Log 2 Rest Log 4 on the landing on Log 2 4 CITY SERIES 60 ...

Страница 110: ...07 14 21 14 Place Log 7 on top of Log 4 ensuring the pin on Log 4 is aligned with the hole on Log 7 13 Place Log 6 on top of Log 3 ensuring the pin on Log 3 is aligned with the hole on Log 6 and that Log 6 rests on the landing on Log 3 5 CITY SERIES 60 ...

Страница 111: ...City Series CST60E 111 installation media 920 393 07 14 21 16 Install Log 9 on top of the pilot as shown below 15 Install Log 8 between Log 3 and Log 4 as shown below 6 CITY SERIES 60 ...

Страница 112: ...112 City Series CST60E installation media 920 393 07 14 21 17 Install Log 11 beside Log 6 18 Install Log 10 at the right end of the unit as shown below 6 11 10 7 CITY SERIES 60 ...

Страница 113: ...b box of black charcoal glass optional or 1lb box of Andriron embers optional around the burner You can add a maximum of 30 pieces of Andriron embers on top of the burner Make sure the burner surround is only 50 covered Correct Coal Placement Final Placement 11 10 8 CITY SERIES 60 ...

Страница 114: ...sold by the foot Threefeetarerequiredtocompletebothsides Glass Your Regency fireplace is supplied with high temperature 5mm tempered outer glass 5mm ceramic inner glass If your glass needs cleaning use an approved glass cleaner available at any authorized dealer Do not use abrasive materials Glass Replacement Maintenance Instructions 1 Always turn off the gas valve before cleaning Forrelighting re...

Страница 115: ...and tighten the two screws Hang the handle back onto the magnet 5 Reverse to Step 1 aeration handle NOTE If the firebox glass logs inner panels etc are already installed the aeration can be adjusted from outside the firebox 1 Remove the centre access panel on the outer trim If finishing material is already installed remove the glass safety barrier and center outer panel See instructions in this ma...

Страница 116: ...heindividualinnerlightcoverandremove 4 Replace the bulb and reverse steps to complete the procedure Regency part 911 208 Oven lamp assembly G9 120V 25W Regency part 911 072 Replacement bulb G9 120 Volt 25 watt Lights are located on top of the unit Inner light covers shown from below Inner light covers close up Inner light cover reassembly order Light cover Light glass Light gasket NOTE Do not hand...

Страница 117: ... front and 4 at rear slide burner to the left away from the orifice and lift out 9 Disconnect the Spark Electrode flame sense step board see wiring diagram for location 10 Lift valve tray out partially and disconnect flexib valve inlet side remove valve tray replace with assembly gasket 11 Reverse Steps 10 1 to complete Burner screw locations tooltip 6 Remove the trim cover on right side of burner...

Страница 118: ...d be checked by a licensed gas service technician during the annual service check Your unit may require more frequent maintenance checks if you notice any changes in how it operates Operational changes to look for can include but are not limited to extended start up time increased fan noise residue carbon build up white build up on the glass firebox increased operating noise etc Should any of thes...

Страница 119: ...City Series CST60E 119 parts list Main Assembly 1 12 2 4 5 7 8 9 10 11 14 6 6 19 20 18 16 17 23 22 25 24 26 23 22 21 23 15 25 24 26 1 ...

Страница 120: ... Control Fuse 3 15 amp Fast Acting N S 911 187 Battery Holder W Switch 584 103 Item Part Description N S 911 324 Remote Control GTMFLSA 0 584 090 N S 911 177 Wire 4 Pos IFC Fan Light N S 911 181 Wire Harness Battery Box Proflame II N S 911 344 Wire Harness PV Assembly N S 911 209 Wire 2 Pos IFC to Lights N S 911 262 ASM Wire Harness IFC w APS Quick Connect N S 911 193 Connector W Jumper N S 911 32...

Страница 121: ...ive 1 4in 1Lb Pkg N S 946 676 Fireglass Copper 1 4 in 1Lb Pkg N S 946 677 Fireglass Starfire 1 4 in 1Lb Pkg N S 946 775 Fireglass Black Reflective 1 4in 5lb Pkg N S 946 776 Fireglass Copper 1 4 in 5lb Pkg N S 946 777 Fireglass Starfire 1 4 in 5lb Pkg N S 946 780 Crushed Glass Coal Black 3 4in 3 5 lbs N S 946 781 Crushed Glass Iceberg Chips 3 4in 3 5 lbs N S 946 735 Firebeads Black 1 lb Pkg N S 946...

Страница 122: ...m Part Description 1 666 038 Upper Lower Glass Clamps Right 2 666 039 Upper Lower Glass Clamps Left A DETAIL A SCALE 1 8 1 2 Item Part Description 1 666 038 Upper Lower Glass Clamps Right 2 666 039 Upper Lower Glass Clamps Left 3 666 534 Firebox Glass Support 2 1 1 2 1 2 3 Lower Glass Clamps 2 ...

Страница 123: ...RITICAL 0 000 SPECIFIED TOLERANCE 0 000 0 031 0 000 REF REFERENCE ONLY ANGULAR 1 TOLERANCES UNLESS OTHERWISE STATED DO NOT SCALE DRAWING 3RD ANGLE PROJECTION REV PART NO FIREPLACE PRODUCTS INTERNATIONAL 946 535 Flush Mount Power Vent SHEAR PUNCH FORM 8 12 2021 DATE SCALE 1 24 Power Vent End of Line Part 946 535 Part Number Description 1 911 112 P Pressure Switch SEnsor includes bracket 2 911 244 P...

Страница 124: ...PECIFIED TOLERANCE 0 000 0 031 0 000 REF REFERENCE ONLY ANGULAR 1 TOLERANCES UNLESS OTHERWISE STATED DO NOT SCALE DRAWING 3RD ANGLE PROJECTION REV PART NO FIREPLACE PRODUCTS INTERNATIONAL 666 945 INLINE POWER VETN ASSEMBLY SHEAR PUNCH FORM 8 12 2021 DATE SCALE 1 8 Part Number Description 1 911 305 P 120 Volt Fan Motor 2 911 112 Vacuum Switch 3 911 047 Silicone Hose sold per foot 1 foot required 4 ...

Страница 125: ...City Series CST60E 125 notes ...

Страница 126: ... Wiring Switches Blowers Blower Control Module Battery Pack Remote Control Systems 2 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crystals Firebeads Volcanic Ceramic Spa Stones 1 All hardware 1 Mesh Glass Safety Barriers 1 Accent Light Bulbs 1 Glass Crazing 1 Conditions Warranty protects against defect in manufacture or FPI factory assembled compon...

Страница 127: ...ation error installation by an unqualified installer incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels lack of regular maintenance and upkeep acts of God weather related problems from hurricanes tornados earthquakes floods lightning strikes bolts or acts of terrorism or war which result in malfunction of the appliance are n...

Страница 128: ...ld consult their local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized selling dealer is unable to provide warranty service please contact FPI by mail at the address listed below Please include a brief descript...

Страница 129: ...r us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases made in CANAD...

Страница 130: ...130 City Series CST60E warranty ...

Страница 131: ......

Страница 132: ...______________________________________ Phone _ ___________________________________________________________ Date Installed ________________________________________________________ Serial _____________________________________________________________ Printed in Canada Regency and City Series are trademarks of FPI Fireplace Products International Ltd Copyright 2021 FPI Fireplace Products International...