56
|
City Series CST60E
installation-non power vent
Vertical Terminations - 5" x 8" (127 mm x 203 mm) Rigid or Flex Pipe
• Two 45
o
elbows equal to one 90
o
elbow. Maximum of six 45
o
elbows allowed.
• Vent must be supported at offsets.
• Minimum distance between elbows is 1 ft. (305mm).
• Maintain clearances to combustibles as listed in the "Clearances" section.
• Horizontal vent must be supported every 3 feet (0.9 m).
• Firestops are required at each floor level and whenever passing through a wall.
• Must use optional rigid pipe adaptor (part# 770-994) when using rigid pipe vent systems
.
Vertical Venting with Three (3) 90
o
Elbows
One 90
o
elbow = Two 45
o
elbows.
V
H1
H
V1
Option
V (min.)
H + H1 (max.) V + V1 (min.)
A)
1' (305 mm)
2' (610 mm)
3' (0,9 m) Min.
B)
2' (610 mm)
3' (0.9 m)
4' (1,2 m) Min.
C)
3' (0.9 m)
4' (1.2 m)
6' (1,8 m) Min.
D)
4' (1.2 m)
5' (1.5 m)
7' (2,1 m) Min.
E)
5' (1.5 m)
6' (1.8 m)
8' (2,4 m) Min.
F)
6' (1.8 m)
7' (2.1 m)
9' (2,7 m) Min.
G)
7' (2.1 m)
8' (2.4 m)
10' (3 m) Min.
Lengths do not include elbow indicated
Restrictor Set 0 - Factory Setting
NO
TES
• For horizontal terminations, the Regency Direct Vent
Flex System may be used for installations with a
maximum continuous vent length of 10 feet (3 m). If
longer runs are required, rigid pipe must be used. With
these options, max. total pipe length is 30 feet (9.1 m)
with min. of 10 feet (3 m) total vertical pipe and max. 8
feet (2.4 m) total horizontal pipe.
• A minimum of 1 ft. (610 mm) is required between all
90
0
elbows.