City Series CST60E
|
115
maintenance
Aeration Adjustment
The burner aeration is factory set, but may need adjusting due to the local
gas supply or altitude. Open the air shutter for a blue flame or close for a
more yellow flame.
Remove
3. Adjust aeration accordingly.
• Pushing lever in opens the air shutter.
• Pulling the lever outward closes the air shutter.
Minimum Air Shutter Opening
NG, NG with logs, NG with volcanic stones: 3/16" (5 mm)
LP, LP with logs, LP with volcanic stones: 3/8" (9-1/2 mm)
4. Remove the handle by lifting up and out. Replace the access door and
tighten the two screws. Hang the handle back onto the magnet.
5. Reverse to Step 1.
aeration
handle
NO
TE
• If the firebox glass, logs, inner panels, etc. are already installed, the
aeration can be adjusted from outside the firebox.
1. Remove the centre access panel on the outer trim. If finishing material is
already installed, remove the glass safety barrier and center outer panel.
See instructions in this manual.
2. Attach the handle to the aeration lever through the access opening. The
handle will slide into position on the lever.
NO
TE
• The aeration handle is located near the right side of the gas
valve access door, attached by a magnet.
NO
TE
• Any damage due to carboning resulting from improperly setting the
aeration controls is NOT covered under warranty.