City Series CST60E
|
31
installation - general
Option 4 - Top and Front
Shown with ventilation opening on top and front (90 sq. in. each) to meet the minimum
requirement of 180 sq. in.
A
10" (254 mm) min.
B
2" (51 mm) min.
C 180 sq. in min.
D 1-1/2" (38 mm) min.
E
3" (77 mm) min.
A
A
C
D
B
D
E
**Option 3 - Front/Back Wall with second ventilation in separate room
Shown with ventilation opening on front and back to meet the minimum requirement
of 180 sq. in.
When on the front and back with second ventilation located in another room (two different pressure
zones), ventilation openings must be the same size and have equally split air openings to balance air flow.
A
B
C
D
A
10" (51 mm) min
B
2" (51 mm) max.
C 90 sq. in. front and back
D 1-1/2" (38 mm) min.
2nd ventilation opening in
separate room