City Series CST60E
|
51
installation-non power vent
Vent Guard - if required*
(Part #946-506/P)
20
5
Horizontal Terminations - Flex Vent 5" x 8" (127 mm x 203 mm)
These venting systems, in combination with the CST60E Direct Vent Gas Fireplace, are tested and listed as a direct vent heater system by Intertek. The
location of the termination cap must conform to the requirements in the vent terminal locations diagram in the "Exterior Vent Termination Locations" section
of this manual.
Regency
®
Direct Vent (Flex) System Termination Kits include all the parts needed to install the CST60E using a flexible vent.
FPI Kit #
Length Contains:
#946-615
4 Feet
1) 8” Flexible Liner (Kit length)
2) 5” Flexible Liner (Kit length)
3) Spring Spacers
4) Thimble
5) AstroCap XL Termination Cap
6) Screws
7) Tube of Mill Pac
8) Plated Screws
9) S.S. Screws #8 x 1-1/2” Drill Point
10) Vinyl Siding Standoff
#946-618
6 Feet
#946-616
10 Feet
NO
TES
• Liner sections should be continuous without any joints or seams.
• Only flex pipe purchased from Regency® may be used for flex
installations.
• Horizontal vent must be supported every 3 feet.
• Regency® Direct Vent System (Flex) is only approved for horizontal
terminations.
• Flex system can only be used up to a maximum continuous vent
length of 10 feet. If longer runs are required, rigid pipe must be used.