City Series CST60E
|
71
installation-power vent
Horizontal Terminations - End of Line Power Vent - Rigid Pipe 4" x 6-5/8" (102 mm x 168 mm)
The minimum components required for a basic horizontal termination
are:
1 Power Vent Kit
1 Rigid Pipe Adaptor
1 Vent Reducer
1 Length of pipe to suit wall thickness and total vent run
(see Table 1)
Wall thickness is measured from the back standoffs to the inside mounting
surface of the termination cap. Create a level surface to mount the vent
terminal. The terminal must not be recessed into siding. Measure the
wall thickness.
Flat Wall Installation
Wall Thickness
(inches)
Vent Length Required
(inches)
4" - 5-1/2"
6"
7" - 8-1/2"
9"
10" - 11-1/2"
12"
9" - 14-1/2'
11" - 14-5/8" Adj. Pipe
15" - 23-1/2"
17" - 24" Adj. Pipe
Pipe Length
Vertical Terminal
Storm Collar
Flashing
Ceiling Firestop
Adj.Pipe Length
Wall Thimble
Rigid Pipe Adapter
(Part # 770-994)
o
90 Elbow
Pipe Length
Vent reducer
(Part # 946-606)
Power Vent Trim
Power Vent Terminal
Frame Assembly
Power Vent Frame
Power Vent Kit
(Part # 946-535)
Table 1
Power Vent Kit with Vent Terminal
1
770-994
Rigid Pipe Adaptor
Sold separately
1
946-606
Vent Reducer (required)
Sold separately
946-535
Power Vent Kit- includes:
Frame, Frame Assembly,
Vent Trim, Fan, and
Terminal
Sold separately
1
911-250/P
45'-5 Wire BX Cable or
Sold separately
1
911-251/P
90' 5-Wire BX Cable
Sold separately
Amount required
for install
4" x 6-5/8" Rigid Pipe
Sold separately
NOTE: *Slip section is mandatory.