Disassembly
48 — English
Vacuum spray degassing — 03.11.2014
Prior to the disassembly, lock out the "DC" degassing lines and the "WC" make-up line from the system and de-pressurise the device.
Then disconnect the device from all electrical power sources.
Proceed as follows:
1. Set the device controller to manual mode, see chapter 8.1.2 "Manual mode" on page 38 .
2. Lock the connections from the device for the "DC" degassing lines.
3. Lock the connections from the device for the "WC" make-up line.
4. Disconnect the device from all electrical power sources.
5. Secure the facility system against unintended reactivation.
6. Disconnect the power cable of the device from the power supply.
7. Disconnect all cables leading from the facility system to the device controller.
8. Open the "CD" 3-ways motor ball valve in the device.
– Wait until the pressure has equalised with the ambient temperature.
9. Remove the degassing lines from the device.
– Ensure that the locking mechanisms at the device are not twisted when you remove the lines.
10. Remove the make-up line from the device.
– Ensure that the locking mechanism at the device are not twisted when you remove the line.
11. Physically remove the device from the system.
12. Drain all residual water from the device.
– At the device, open the connections for the degassing lines and the make-up.
13. Use a suitable container to catch the residual water.
The device is removed.