Operation
Vacuum spray degassing — 03.11.2014
English — 43
ER Code
Alarm
Floating contact
Cause
Remedy
Alarm reset
19
Stop
˃
4 hours
-
Device is in stop mode for
more than 4 hours.
Set the controller to
Automatic mode.
-
20 Maximum
make-
up quantity
-
Set value exceeded.
Reset the "Make-up
quantity" meter in the
Customer menu.
Quit
21 Maintenance
recommended
-
Set value exceeded.
Carry out maintenance.
Quit
24
Softening
-
•
Set value for soft water
capacity exceeded.
•
Time interval for
replacement of the
softening cartridge
exceeded.
Replace the softening
cartridges.
Quit
30
I/O module fault
-
•
I/O module defective.
• Connection
between
option card and
controller faulty.
• Option
card
defective.
•
Replace the I/O
module.
•
Check the connection
between option card
and controller.
•
Replace the option
card.
-
31 EEPROM
defective
Yes •
EEPROM
defective.
•
Internal calculation error.
Contact the Reflex
Customer Service.
Quit
32 Undervoltage Yes
Supply
voltage
not achieved.
Check power supply.
-
33 Adjustment
parameter faulty
- EPROM
parameter
memory
defective.
Contact the Reflex
Customer Service.
Quit
34 Main
board
communication
faulty
- •
Connecting
cable
defective.
•
Main board defective.
Contact the Reflex
Customer Service.
Quit
35 Digital
input
voltage faulty
-
Short-circuit of input voltage.
Check the wiring at the
digital inputs (water
meter, for example).
-
36 Analogue
input
voltage faulty
-
Short-circuit of input voltage.
Check the wiring at the
analogue inputs
(pressure/level).
-
37
No input voltage
at the 3-ways
motor ball valve
-
Short-circuit of input voltage.
Check the wiring at the 3-
ways motor ball valve.
-