RDL-2000
Installation Guidelines
70-00144-01-01
Proprietary Redline Communications © 2011
Page
8
of 52
March 9, 2011
1.3 Service & Warranty Information
Refer all repairs to qualified service personnel. Do not remove the covers or modify any
part of this device, as this action will void the warranty.
Locate the serial numbers and record these on your registration card for future
reference. Use the space below to affix serial number stickers. Also, record the MAC
address identified on the unit product label.
Redline does not endorse or support the use of outdoor cable assemblies: i) not supplied
by Redline, ii) third-party products that do not meet Redline's cable and connector
assembly specifications, or iii) cables not installed and weatherproofed as specified in
the Installation Guidelines manual (70-00073-01-XX). Refer to the Redline Limited
Standard Warranty and RedCare service agreements.
1.4 Lightning Protection
WARNING: The following notes are general recommendations for the system. The
wireless equipment should be installed by a qualified professional installer who is
knowledgeable of and follows local and national codes for electrical grounding and
safety. Failure to meet safety requirements and/or use of non-standard practices and
procedures could result in personal injury and damage to equipment.
All outdoor wireless equipment is susceptible to lightning damage from a direct hit or
induced current from a near strike. A direct lightning strike may cause serious damage
even if these guidelines are followed. Lightning protection and grounding practices in
local and national electrical codes serve to minimize equipment damage, service
outages, and serious injury. Reasons for lightning damage are summarized as:
a) Poorly grounded antenna sites can conduct high lightning strike energy into
equipment.
b) Lack of properly installed lightning protection equipment can cause equipment
failures from lightning induced currents.
A lighting protection system provides a means by which the energy may enter earth
without passing through and damaging parts of a structure. A lightning protection system
does not prevent lightning from striking; it provides a means for preventing damage to
equipment by providing a low resistance path for the discharge of energy to travel safely
to ground. Improperly grounded connections are also a source of noise that can cause
sensitive equipment to malfunction.
A good grounding system disperses most of the surge energy from a lightning strike
away from the building and equipment. The remaining energy on the Ethernet cable
shield and conductors can be directed safely to ground by installing a lightning arrestor
in series with the cable.
If you have determined that it is appropriate to install lightning protection for your system,
the following general industry practices are provided as a guideline only:
1.
The AC wall outlet ground for the indoor POE adapter should be connected to the
building grounding system.
2.
Install a lightning arrestor in series with the Ethernet cable at the point of entry to the
building. The grounding wire should be connected to the same termination point
used for the tower or mast.
3.
Install a lightning arrestor in series with the Ethernet cable as close to the outdoors
unit as practical. The grounding wire should be connected to the same termination
point used for the tower or mast.
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299