RDL-2000
Installation Guidelines
70-00144-01-01
Proprietary Redline Communications © 2011
Page
38
of 52
March 9, 2011
4.5.4 Install Indoor PoE Power Adapter
The indoor Power-over-Ethernet (PoE) power adapter provides operational power and
the Ethernet connection to the RDL-2000. The PoE is auto-sensing 110-240 VAC. A
grounded AC outlet must be provided within about one meter of the PoE adapter
mounting location. The AC power cable is supplied with a grounding power plug. Do not
defeat this important safety feature.
The indoor end of the Redline supplied Ethernet cable is terminated with a non-hooded
RJ-45 connector. This connects to the OUTPUT (DATA & POWER) port of the indoor
PoE power adapter. The minimum diameter conduit or hole required is 18 mm (11/16 in).
The power block provides two Ethernet interfaces:
INPUT (DATA)
:
Connection to local network equipment.
OUTPUT (DATA & POWER)
: Signal and power to the RDL-2000.
Warning to Service Personnel: 48 VDC
Customer equipment including personal computers, routers, etc., must be connected
only to the INPUT (DATA) port on the PoE unit. Only the outdoors Ethernet interface
cable connecting to the RDL-2000 can be safely connected to the OUTPUT (DATA &
POWER) connector. Connecting customer premises Ethernet equipment directly to
the OUTPUT (DATA & POWER) connector on the Power-over-Ethernet power
adapter may damage customer equipment.
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299