5.2 Bench Test Setup
5.2.1 Customer Supplied Equipment:
1.
Windows™ computer with Redline 'Link Manager' application installed.
2.
Second computer is preferred to perform link data testing.
3.
Pair of RF attenuators (70 dB recommended) for indoor testing.
4.
AC power (for PoE).
Figure 36: Ref. - Bench Test Setup (No Antenna)
Note: The default IP address is 192.168.25.2. The default Admin password is:
admin
. To
avoid Layer-2 loops, only one RDL-2000 should be connected to a local LAN.
5.2.2 Assemble Test Setup
1.
Connect the units as shown in the diagram and power on all equipment.
2.
Transfer the RDL-2000 license files to PC#1 and PC#2.
5.2.3 Connectivity Test
1.
On PC #1, go to the Ping screen. Set the test for 1024 byte packets,
transmitted each 1000 ms, to address 192.168.25.2 (slave unit).
2.
Click the Start button and observe that the slave unit is responding.
3.
Click the Stop button to terminate the ping test.
4.
Set the test for 5000 byte packets, transmitted each 1000 ms, to address
192.168.25.20 (PC #2).
5.
Click the Start button and observe that that PC #2 is responding.
6.
Click the Stop button to terminate the ping test.