Table 28
:
Diag. - System Log Messages
Log Message
Description
212-Error firmware configuration! An unexpected error occurred while writing the onboard
firmware configuration. Try to repeat the process.
213-Firmware programming
failed!
The firmware programming failed.
214-Error while loading version
control!
Software version control data was not loaded successfully.
215-Log buffer full!
The log buffer overflowed.
216-Invalid Options Key!
User entered an invalid Product Options key.
217- PLL unlocked!
One or more RF synthesizers unlocked. The unit stopped
RF transmissions and attempted to reprogram the
synthesizers. If this message repeats or if the RF link is not
back on, try to reset the terminal. If the problem persists,
contact customer support.
218-Outdoor unit over
temperature!
The
T
ransceiver's internal temperature rose above 185F /
85C. The transceiver will shut down for 30 seconds to allow
cooling.
219-Excessive DC loss on IF
cable!
The DC voltage at the transceiver (carried by the IF cable
from the terminal) is lower than the required 24 VDC. Check
the IF cable and connectors.
220-Outdoor unit power supply
fault!
Indicates a fault in the transceiver's power supply. This error
could be due to a problem with the internal power supply, or
with the power source from the terminal. If the 'Excessive
DC loss on IF cable' error is also indicated, check the IF
cable and connectors. If not, the
T
ransceiver requires
servicing.
221-\public\ community can't be
deleted!
The default 'Public' SNMP community cannot be deleted.
222-Max. community number
already defined!
No more communities may be defined, as the maximum
number has been reached
223-Community name already
defined!
The name for the SNMP community has already been used.
Choose another name.
224-MIB initialization error!
MIB construction process generated an error. Try to reset
the terminal. If the problem persists, contact customer
support.
225-Error while loading SNMP
configuration!
EEPROM memory was corrupted and the SNMP
configuration couldn't be loaded. Default SNMP
configuration was loaded.
226-Error while saving SNMP
configuration!
SNMP configuration saving process wasn't successfully. Try
again. If the problem persists, contact customer support.