TYPE
T50
T90
TEMP °F
Relative Humidity
(non-
condensing)
Application Notes
A1
A2
A3
PID
--
<3
-40° to 131°
0 to 99%
20%
40%
60%
IR
<5
<10
-40° to 158°
up to 99%
Millenium sensor
20%
40%
60%
EC
<20
<60
-4° to 104°
15 to 90%
20%
40%
60%
EC
<30
<90
-4° to 104°
15 to 90%
20%
40%
60%
EC
<20
<60
-4° to 104°
20 to 95%
20%
40%
60%
EC
--
<30
-4° to 104°
10 to 95%
Available with or without H2S filter
20%
40%
60%
PID
--
<3
-40° to 131°
0 to 99%
20%
40%
60%
IR
--
<30
-4° to 122°
0 to 95%
20%
40%
60%
IR
<15
<30
-4° to 122°
0 to 95%
Specify span when ordering
20%
40%
60%
IR
<5
<10
-40° to 158°
up to 99%
Millenium sensor
20%
40%
60%
IR
--
<30
-4° to 122°
0 to 95%
Low power IR in development
20%
40%
60%
IR
--
<30
-4° to 122°
0 to 95%
Low power IR
20%
40%
60%
EC
--
<30
-4° to 122°
15 to 90%
20%
40%
60%
EC
--
<60
-4° to 122°
15 to 90%
20%
40%
60%
EC
--
<60
-4° to 122°
15 to 90%
20%
40%
60%
CB
3
8
-4° to 158°
0 to 100%
20%
40%
60%
IR
<5
<10
-40° to 158°
up to 99%
Millenium sensor
20%
40%
60%
IR
<5
<10
-40° to 158°
up to 99%
Millenium sensor
20%
40%
60%
IR
<5
<10
-40° to 158°
up to 99%
Millenium sensor
20%
40%
60%
PID
--
<3
-40° to 131°
0 to 99%
20%
40%
60%
EC
--
<200
-22° to 122°
15 to 90%
20%
40%
60%
EC
<30
<80
14° to 104°
15 to 90%
20%
40%
60%
IR
<5
<10
-40° to 158°
up to 99%
Millenium sensor
20%
40%
60%
EC
<30
<120
14° to 104°
20 to 95%
20%
40%
60%
EC
--
<80
-22° to 122°
15 to 90%
20%
40%
60%
EC
<40
<70
-4° to 104°
16 to 90%
20%
40%
60%
EC
<40
<60
-4° to 104°
15 to 95%
20%
40%
60%
EC
--
<200
-22° to 122°
15 to 90%
20%
40%
60%
EC
--
<120
-22° to 122°
15 to 90%
20%
40%
60%
EC
--
<90
-4° to 104°
15 to 90%
20%
40%
60%
EC
--
<55
-22° to 122°
15 to 90%
20%
40%
60%
IR
--
<30
-4° to 122°
0 to 95%
Specify span when ordering
20%
40%
60%
IR
--
<30
-4° to 122°
0 to 95%
Low power IR
20%
40%
--
IR
<5
<10
-40° to 158°
0 to 99%
Millenium sensor
20%
40%
60%
EC
--
<30
-22° to 122°
15 to 90%
20%
40%
60%
EC
--
<75
-22° to 122°
15 to 90%
20%
40%
60%
EC
--
<60
-22° to 104°
15 to 85%
20%
40%
60%
EC
--
<40
-4° to 122°
15 to 90%
20%
40%
60%
EC
--
<15
-22° to 131°
5 to 95%
19
18
17
EC
--
<150
-4° to 122°
15 to 90%
20%
40%
60%
IR
<5
<10
-40° to 158°
up to 99%
Millenium sensor
20%
40%
60%
EC
--
<20
-22° to 122°
15 to 90%
20%
40%
60%
IR
--
<30
-4° to 122°
0 to 95%
20%
40%
--
IR
<5
<10
-40° to 158°
0 to 99%
Millenium sensor
20%
40%
60%
IR
--
<30
-4° to 122°
0 to 95%
Low power IR
20%
40%
60%
IR
<5
<10
-40° to 158°
up to 99%
Millenium sensor
20%
40%
60%
EC
--
<60
-4° to 104°
10 to 95%
20%
40%
60%
EC
--
<40
-22° to 122°
15 to 90%
20%
40%
60%
EC
--
<30
-22° to 122°
16 to 90%
20%
40%
60%
Содержание 10-0517
Страница 4: ...UM 1096 Revision A III Drawings 44...
Страница 10: ...UM 1096 Revision A 5 Figure 2 Remote Sensor Enclosure Mounting Dimensions...