background image

20 years of experience in developing radiation detection 

technology for consumers and government agencies.

 RADEX MR107 Quick Start

Thank You for purchasing the RADEX MR107 Radon 
Gas Detector. This unit is designed to detect and mea-
sure the Equivalent Equilibrium Volume Activity (EEVA) 
of the Rn-222 (radon) in the air, as well as volumetric 
activity of its decay products commonly called “daugh-
ters of radon”.

RADEX MR107 can detect dynamic changes in gas con-
centration, sound an alarm when the gas levels are no 
longer safe, transfer data onto a PC for analysis. 

Features and capabilities:

• measuring the volume activity of radon in the air 

(EEVA); relative humidity and air temperature

• adjustable audio alarm that reacts to excessive 

EEVA levels of radon

• tracking of dynamic changes in radon EEVA, air 

temperature and relative humidity.

• calculating minimal, median and maximum values 

of radon EEVA. Air temperature and relative 

humidity.

• storing gathered data in internal memory
• transferring stored data to PC.
• working with data via PC software

GETTING STARTED

This device does not require any special preparations 

or a warmup and is ready as soon as is activated.

The device draws power from an internal battery or 

from an external power source of 5V. To connect to an 
outside power source use the micro-USB port located on 
the  back side of the device.

PLACING THE DEVICE

The proper placement of the radon gas detector 

should be roughly at the same height as a person’s head 

(breathing), ie – on the floor of a game room; on a table 
at an office; on a nightstand in a bedroom.

Radon detector uses highly delicate sensors, hence it 

is strongly recommended to avoid exposing ventilation 
holes on the device to direct sunlight, as well as keeping 
the device away from sources or strong electromagnet-
ic radiation such as cell phones, computers, radios and 
high-power electronic devices.

In the case of dangerously high radon levels it is neces-

sary to fully and properly ventilate the venue and prefera-
bly to locate the source of the gas leak and to remove it if 

possible. Another option is to seal off the leak. 

TURNING THE DEVICE ON AND OFF

To turn the device ON 

1.  Activate the device using the 

“Power”

 switch 

located on the back side. The device will go into 

Waiting

 mode.

2.  Press   on the front side.
3.  The device will switch into 

Measuring

 mode.

Turning the device OFF. 

1.  Press and hold the 

 

button on the front side of 

the device for 5 seconds. The device will switch 
from 

Measuring

 mode to 

Waiting

 mode.

2.  For extended storage or transporting please use 

the “Power” switch on the back side. 

OPERATING THE DEVICE

As the device is activated, the model name appears 

on its screen and after 5 seconds the device is in 

Mea-

suring

 mode. At the same time there is a status bar and 

information about the latest measurements.

To save battery power while operating unplugged, the 

device  will  turn  off  the  screen  after  some  time.  Mean

-

while the measuring continues which is indicated by the 
blinking 

“work in progress”

 light.

To turn on the screen press the   on the front panel of 

the device. If the device is plugged in the screen remains 
always on. 

IMPORTANT: To achieve the highest possible 

accuracy we strongly recommend to measure 

continuously for no less than 72 hours.

screen

On / Off / Switch information 

on the screen

Work in  

Progress 

 light

USB port to link to a PC or to charge the battery

Power OFF 

switch

Front

Back 