Operator Unit
130--613
Operator Unit
75
Edition: Sept. 10, 2005
3648/130--613.DOC010102
6.3.2.5
Software Versions
With this submenu the software status of all processor program--memories of PCB of the
connected Gyros (max. three) and of the Distribution unit are displayed.
Dim
Up
Dim
Down
SW Versions
Set
Select
Gy1/15
Gy2/16
110--233.P01.E10.00
P00.E00.00
110--233.P02.E10.00
110--233.P03.E10.00
110--233.P04.E10.00
DU /20
138--118.P01.E10.00
138--118.P02.E10.00
138--118.P03.E10.00
Set Service Timeout to 120s
Exit
Service Timeout in xxxs
Note: There is no display for PCB‘s with an older development status
Figure 73: Controls and Indicators on the Operator Unit
( Submenu “SW Versions” displayed)
One Gyro and one Distribution Unit connected.
Display
Meaning
Gy1/15
Gyro 1 with CAN--bus address 15
110--233.P01.E10.00
110--233 = Compass STD 22
P01 = Program at the Sensor PCB
P02 = Program at the Power PCB
P03 = Program for MC 1 at the Outer Sphere PCB
P04 = Program for MC 1 at the Outer Sphere PCB
E10.00 = Software version
DU /20
Distribution Unit with CAN--bus address 20
138--118.P01.E10.00
138--118 = Distribution Unit
P01 = Program of the CAN--bus Processor
at the Interface PCB
P02 = Program of the DV--bus Processor
at the Interface PCB
P03 = Program at the I/O PCB
E10.00 = Software version
Gy2/16
Gyro 2 with CAN--bus address 16
P00.E00.00 older development status