Operator Unit
130--613
62
3648/130--613.DOC010102
Edition: March 11, 2005
6.3.1.3
Damping of the Rate of Turn
With this function it is possible to damp the influence of the seastate to the Rate of Turn.
This Damping only acts to analogue RoT--devices.
RoT--devices which are controlled via NMEA--telegrams are controlled with the min.
damping and have to be damped separately.
RoT data are displayed unfiltered; selected damp--values
only act to an analogue output (for example: the output
RoT in the Distribution Unit, type 138--118).
Basic menu ----> select “Menu” line ----> select “Service” line ----> select function “Rate of
Turn.”.
Dim
Up
Dim
Down
ROT [
°
/Min]
Set
1
2
Gyro1:
+001.0
°
Gyro2:
--000.3
°
Mag:
--007.0
°
Rate Gyro +004.4
°
Damp:
0
Damp:
1
(selected)
Damp:
2
Exit
Service Timeout in 55 s
Select
Figure 62: Controls and Indicators on the Operator Unit
( Function ”Rate of Turn“)
With this function the Rate of Turn of selected heading sensor is displayed.
A positive sign means a Rate of Turn to starboard, a negative sign means a rate to
portside.
The damp menu line is selected by pressing the “Select” key (Figure 62/1). Enter the
respective damp--value by pressing “Set” (Figure 62/2) and this line will be marked with
“(selected)”.