Operator Unit
130--613
Operator Unit
51
Edition: Jan. 11, 2006
3648/130--613.DOC010102
6
Adjustment of additional operation modes with the service menu
After selection of the menu line “Menu” below mentioned submenus are displayed to
select other operational modes:
-- Diff--Alarm (Difference Alarm) (see section 6.1)
-- Panel Setup (see section 6.2)
-- Service (see section 6.3)
-- Quick Settling (see section 3.4)
6.1
Difference Alarm
In such a compass system all connected heading sensors are compared together
constantly. If there is a deviation more than the adjusted threshold than there will be a
difference alarm displayed and output.
A conclusion about which of the connected sensors deviates is not possible.
Each connected sensor has to be checked depending his function.
All adjustments necessary for a difference alarm are shown in the table below.
Parameter
G*/M
G/G*
Minimum threshold
3
°
1
°
Maximum threshold
89,9
°
89,9
°
Increment
1/10
°
1/10
°
*
“G” can be Gyro or GPS. A GPS is dealt as a Gyro.
In case of a reduced availability of the GPS (STD21)
a difference alarm may occur.
For reasons of a reduced availability see manual
3717, section “Principles of Operation”.
The following table shows the connectable sensors referring to their comparison
procedures.