Operator Unit
130--613
10
3648/130--613.DOC010102
Edition: Sept. 10, 2005
GYRO 1
------.--
°
Heading (Heating)
Gyro 1 selected.
Gyro 1 in the heating stage, time to
activate quick settling (3 minutes) is
over.
GYRO 1
068.7
°
Heading (Settling)
Gyro 1selected.
Gyro 1 in settling stage (heating
stage is over).
Heading information still inexact, see
compass STD 22 manual.
Gyro 2:
067.9
°
(X)
Gyro 3:
067.8
°
Magnet: 069.0
°
“X” could be:
- - - .-
°
(E)
Error, than heading information
is not displayed.
068.9
°
(Q)
Quick Settling, the heading value
to which the gyro will settle is
displayed.
068.9
°
(S)
Settling Stage, the Gyro is still
settling, heading is displayed,
the precision is still restricted.
- - - .-
°
(H)
Heating stage, the activation of
the quick settling function is not
possible, time to activate this
function (3 minutes) is over.
QS possib
Quick Settling possible,
during 3 minutes after switching
on.
068.9
°
(C)
Caution. This warnings show
short disturbances, which lead
(if not debugged) long dated to a
breakdown.
For more details see compass
STD 22 manual, section 2.2.2.4