Wuxi Raycus Fiber Laser Technologies Co., Ltd.
User Guide of Raycus RFL-A6000D~A12000D
31
5.2 REM mode
5.2.1AD enable mode
When both A1 and A6 of XP1 are set high, the laser operates in AD mode, and the current laser
power is determined by the analog voltage of pin 1 and pin 2 of XP4; When A6 of XP1 is set low or
suspended, the current laser power is set by sending "SDC XX" command through PC software or
communication.
5.2.2Emission external control
When both A1 and A3 of XP1 are set high, the laser is in the internal control mode, and the light
output is controlled by the computer software's light on button or by communication sending "EMON" to
control the light output, and "EMOFF" to control the light off; When A1 of XP1 is set high, A3 is
suspended or set low, the laser is in the external control mode, and the output light is determined by the
high and low levels of A2, XP2-1 and pin 2 MOD signals of xP1.
5.2.3Red light control
When both A1 and A3 of xP1 are set high, the laser is in the red light internal control mode, and the
red light is controlled by the computer software red light button or communication to send "ABN" and
"ABF" used to control the ON and OFF of the red light; When A1 of XP1 is set high, A3 is suspended or
set low, the laser is in external control mode, and the red light is controlled by A5 ofXP1.
The red-light module in the laser works by means of communication, so there is a time delay of at
least 10 MS when the red light is turned on and off.
When the red light is on, the laser cannot be set to ready. Only when the red light is off, can the
laser be ready.
5.2.4Programming mode
When A1 of XP1 is set high and A8-A14 is not 0, the laser is in programming mode. At this time, the
output light of the laser is controlled by A2 of XP1, and the output wave of the laser is determined by the
edited wave.