Wuxi Raycus Fiber Laser Technologies Co., Ltd.
User Guide of Raycus RFL-A6000D~A12000D
18
Table 5 XP2 security interface definition
Pin Number
Type
Description
1
MOD+
Light control, voltage input signal
laser ON
:
4
~
30V; Laser OFF
:
-3
~
2V
Maximum modulation frequency 2kHz
2
MOD-
3
OUT
(
FET S pole
)
Laser output indication, MOS pipe D
、
S output
The light-emitting MOS pipe is turned on
The light-emitting MOS pipe is turned off, current
<
0.5A,Votage
<
30V
4
OUT(FET D pole)
5
OUT
Light warning light negative
,
current
<
100mA
6
OUT
Main power on alarm light negative
,
current
<
100mA
7
OUT
(
24V
)
Output light and main power on alarm light positive
,
current
<
400mA
8
IN
Remote main control board power on, cannot be external voltage or ground. When
pin 8 and 9 are closed, the main control board is powered on, the main control board
is powered off when 8 and 9 feet are closed.
9
IN
10
OUT (24V)
Output light and main power on alarm light positive
,
current
<
400mA
11
OUT
Front panel emergency output 1, relay contact output, passive contact
current <100 mA, voltage<30V
The current panel stop press ,11,14 open, or short circuit
14
OUT
12
OUT
Front panel emergency output 2, relay contact output, passive contact
current <100 mA, voltage<30V
The current panel stop press ,12,13 open, or short circuit
13
OUT
15
OUT (FET S pole) Main power supply power on output indication, MOS pipe D
、
S output
The MOS pipe is turned on when the main power is turned on
The MOS pipe is turned off when the main power is turned off
current<0.5A,voltage<30V
16
OUT(FET D pole)
17
IN
Interlock1 import
,
Active contacts
,
Normal short connection 17
、
20,
no external voltage or grounding
20
IN
18
IN
Interlock2 import
,
Active contacts
Normal short connection18
、
19,
no external voltage or grounding
19
IN
21
IN
Remote main power supply power up, the Power button function on thefront panel is
the same, when the 21,22 feet closed, start the main power supply, active contact, no
external voltage or grounding.
22
IN
23
OUT
The laser has been powered on and output
Disconnected - laser key switch is in the OFF position
Closed - laser key switch is in ON or REM position
External voltage signal, currnet<0.5A,voltage<30V
24
OUT