Wuxi Raycus Fiber Laser Technologies Co., Ltd.
User Guide of Raycus RFL-A6000D~A12000D
28
e) Select the required control mode according to 1.4 control mode, turn on the key switch, and start
the main power supply waiting for the laser to Ready. When the laser Ready, the green light
comes in the tricolor above the machine, representing that the laser can light.
5 Control Mode Selection
Raycus high-power continuous wave laser has two control modes: respectively ON mode and REM
mode
,
the user can select mode that needs to enter through the key to the front panel.
Table 10 Function of REM mode and ON mode
ON
mode
AD
mode
Emission
control
Programming
mode
Power
Emission and
closing of the laser
Red-light
close
①
close
②
-
communication
⑬
communication
⑪
communication
⑫
enable
③
close
②
-
XP4-1
、
2pin pressure
communication
⑪
communication
⑫
close
①
enable
④
-
communication
⑬
XP2-1
、
2pin level
communication
⑫
enable
③
enable
④
-
XP4-1
、
2pin pressure
XP2-1
、
2pin level
communication
⑫
REM
mode
close
⑤
close
⑥
close
⑦
communication
⑬
communication
⑪
communication
⑫
enable
⑧
close
⑥
close
⑦
XP4-1
、
2pin pressure
communication
⑪
XP1-A1
、
A5
is high level
close
⑤
enable
⑨
close
⑦
communication
⑬
XP1-A1 laser request is
high.
XP1-A2 laser light output
enable is high.
XP2-1,2 input MOD
signal
XP1-A1
、
A5
is high level
enable
⑧
enable
⑨
close
⑦
XP4-1
、
2pin pressure
XP1-A1 laser request is
high.
XP1-A2 laser light output
enable is high.
XP2-1,2input MOD
signal
XP1-A1
、
A5
is high level
close
⑤
enable
⑨
enable
⑩
determined by
programming
command
XP1-A1 laser request is
high.
XP1-A2 high level
indicates operating
programs
XP1-A1
、
A5
is high level