Wuxi Raycus Fiber Laser Technologies Co., Ltd.
User Guide of Raycus RFL-A6000D~A12000D
38
6.6 REM mode power communication set out light external control
Figure 26 Wiring diagram of setting power communication as emission external control on REM mode
operation methods
:
a) The rear panel air switch hits ON to supply power to the laser.
b) Front panel key switch to REM, the laser into REM mode.
c) Shorting pin 8 and pin 9 on XP2 to supply power to the main control board.
d) XP1-A1 is connected to 24V.
e) XP1-A5 is connected to 24V to turn on the red light; XP1-A5 is connected to 0V to turn off the
red light after checking the optics.
f) XP1-C1 is connected to 24V, and the main power is turned on (you can also press the LASER
button directly, or the upper computer software points the main power ON.).
g) wait for the green light of the laser tricolor lamp to light up, the laser preparation work is
completed.
h) The software of the upper computer sets the light output power, XP1-A2 connects to 24V and
controls the board MOD signal.
i) Check the laser tricolor lamp red light is on and the laser is outputting light.