The boiler carries out the startup stages in sequence according to the procedures defined by the parameters that manage levels and
times, reaching the work condition unless anomalies or alarms occur, according to the following table:
Status
Devices
igniter
Fume extr.
auger
exch.
OFF
OFF
OFF
OFF
OFF
START - PREHEAT
ON
ON
OFF
OFF
PELLET PRELOAD
ON
ON
ON
OFF
AWAITING FLAME
ON
ON
OFF
OFF
PELLET LOADING
ON
ON
ON
OFF
FIRE PRESENT
OFF
ON
ON
ON
WORK
OFF
ON
ON
ON
WORK MODULATE
OFF
ON
ON
ON
BRAZIER CLEANING
OFF
ON
ON
ON
FINAL CLEANING
OFF
ON
OFF
-
Do not use flammable liquids to light the unit.
In case of persistent failed lighting, contact the Service Centre.
4.4 Work stage
After the ‘STARTUP’ stage, the boiler goes to the ‘WORK’ mode which is the normal operation mode.
The user can adjust the heating power from the max. value of 5 to a min. of 1 with the buttons ‘P5’ and ‘P6’.
DHW circuit function activation ON is displayed by the segment/LED [A].
Button ‘P6’
Button ‘P5’
Power set to 3
Real power in work equal to 1
Make sure to check the pellet level in the hopper so that the flame does not go out due to lack of pellets.
Make sure the unit is off when loading pellets.
The pellet hopper lid must always remain closed; it must only be opened when loading fuel.
The bags of pellets must be kept at least 1.5 m from the boiler.