Calibration and discharging residual material
85
9
Proceed as follows:
NOTICE
Carry out the calibration
on the left side of the machine only
(viewed from the
direction of travel). For safety reasons, however,
both
spreading discs must be
removed.
1.
Take the adjustment lever
[1] from the bracket.
Figure 9.4:
Adjustment lever position
2.
Loosen the cap nut [3] of the
spreading disc with the ad-
justment lever.
3.
Remove the spreading disc
from the hub.
Figure 9.5:
Loosen cap nut