M3SR Series 4100
Basic Configuration of the Radio
2.32
Operating Manual 6175.4760.02 – 01
2.8 Basic Configuration of the Radio
The radio can be controlled and monitored via local area network (LAN) with one or more
external control units also connected to the LAN (see sect. 1.9 Radio Control). To guarantee
proper operation in this case it is required to change the default Internet protocol (IP) settings
of the radio (for default IP settings of the radio see Table 2.1) as well as the default IP settings
of the control unit (for default IP settings of the control unit see sect. 2.9 Basic Configuration
of the Control Unit) before connecting the radio(s) and control unit(s) to the LAN.
If your radio is controlled via built-in control unit and you do not want to connect your
radio to a LAN, you may skip the following sections and continue with section 3.
There are two possibilities to change the radio IP settings:
•
Using a built-in control unit (if available)
•
Using the upd32.exe tool provided by Rohde & Schwarz.
Both are explained in this documentation.
Table 2.1 Default IP Settings of a Radio
Be careful if you change the IP settings. For the configuration of a greater network,
detailed knowledge concerning IP networks is required. Such knowledge is not im-
parted by this documentation. Please ask your network administrator or refer to ap-
propriate technical literature, if necessary.
Default Radio IP Address
192.168.52.34
Default Radio IP Netmask
255.255.255.000
Default Radio IP Gateway
0.0.0.0 (no gateway)
Default Local Control Unit IP Address
192.168.52.218
Содержание M3SR 4100 Series
Страница 15: ...M3SR Series 4100 Documentation Overview xiv Operating Manual 6175 4760 02 01...
Страница 48: ...M3SR Series 4100 Index 34 Operating Manual 6175 4760 02 01 ZF4401 mod 02 2 10...
Страница 70: ...M3SR Series 4100 Radio Control 1 22 Operating Manual 6175 4760 02 01...
Страница 116: ...M3SR Series 4100 Example Configuration 2 46 Operating Manual 6175 4760 02 01...
Страница 336: ...M3SR Series 4100 Priority Channel 3 220 Operating Manual 6175 4760 02 01...
Страница 546: ...M3SR Series 4100 Further Settings are Relevant for SECOM H Operation 4 210 Operating Manual 6175 4760 02 01...
Страница 696: ...M3SR Series 4100 Remote Control 8 4 Operating Manual 6175 4760 02 01...
Страница 697: ...Operating Manual 6175 4760 02 01 9 1 M3SR Series 4100 Drawings 9 Drawings...
Страница 706: ...M3SR Series 4100 Drawings 9 10 Operating Manual 6175 4760 02 01...