Operating Manual 6175.4760.02 – 01
4.93
M3SR Series 4100
Changing the Timeout for Data Links
4.4.5.4
Changing the Timeout for Data Links
Softkey
Type
Description
Editor
In the central area the currently active value is
displayed.
1.
Press softkey 'Data Link Timeout'.
2.
Change value with the knob.
3.
Press 'ENT' to confirm.
Possible values:
0 s to 3600 s
0 means infinite link timeout!
stepwidth of 1 s
For ALE-3G data links (internal modem and
xDL links) the following is valid:
If there is no transmit activity and the radio
does not see any input signal, a terminate
command will be sent automatically after this
timeout is reached.
For ALE-2G links this parameter is not used at
all.
Содержание M3SR 4100 Series