M3SR Series 4100
Menu Split Site 1/2 (3041)
3.70
Operating Manual 6175.4760.02 – 01
Softkey
Description
Possible Values
Navigate to the previous menu (Radio MTC 1/7, see
sect. 3.4 Radio Maintenance).
The Split Site Controller connects to the chosen Split Site
Receiver and Transmitter displayed in the central area of
this menu.
The status of the connection is displayed in the central
area of the screen.
Possible connection status:
•
not connected
•
connecting
•
connection established
•
config in progress
•
operational ( configura-
tion successful, “GO LED”
on)
•
controller internal error
•
connection to unit failed
•
config of unit failed
•
Built-in test of unit failed
(“GO LED” off)
After pressing the ‘Connect’ softkey, the softkey ‘Discon-
nect’ appears on the same place and allows the operator
to terminate the connection to the Split Site radios by
pressing it.
Open a listbox with the name of predefined Split Site
Transmitters.
Use the knob to select the Split Site Transmitter to connect
to.
Press 'ENT' to confirm.
Any of the radios configured
as Split Site Receiver into this
Split Site Controller through
the R&S RMNS or using the
MMI (see sect. 3.4.4 Menu
Split Site 2/2 (3042))
Open a listbox with the name of predefined Split Site Re-
ceivers.
Use the knob to select the Split Site Receiver to connect to.
Press 'ENT' to confirm.
Any of the radios configured
as Split Site Receiver into this
Split Site Controller through
the R&S RMNS or using the
MMI (see sect. 3.4.4 Menu
Split Site 2/2 (3042))
Navigate to the menu Split Site 2/2 (see sect. 3.4.4 Menu
Split Site 2/2 (3042)).
Содержание M3SR 4100 Series
Страница 15: ...M3SR Series 4100 Documentation Overview xiv Operating Manual 6175 4760 02 01...
Страница 48: ...M3SR Series 4100 Index 34 Operating Manual 6175 4760 02 01 ZF4401 mod 02 2 10...
Страница 70: ...M3SR Series 4100 Radio Control 1 22 Operating Manual 6175 4760 02 01...
Страница 116: ...M3SR Series 4100 Example Configuration 2 46 Operating Manual 6175 4760 02 01...
Страница 336: ...M3SR Series 4100 Priority Channel 3 220 Operating Manual 6175 4760 02 01...
Страница 546: ...M3SR Series 4100 Further Settings are Relevant for SECOM H Operation 4 210 Operating Manual 6175 4760 02 01...
Страница 696: ...M3SR Series 4100 Remote Control 8 4 Operating Manual 6175 4760 02 01...
Страница 697: ...Operating Manual 6175 4760 02 01 9 1 M3SR Series 4100 Drawings 9 Drawings...
Страница 706: ...M3SR Series 4100 Drawings 9 10 Operating Manual 6175 4760 02 01...