M3SR Series 4100
Changing the Release Time
3.146
Operating Manual 6175.4760.02 – 01
3.7.2.11
Changing the Release Time
Softkey
Softkey Type
Description
Listbox
The currently selected release time is dis-
played in the central area.
1.
Press 'Release Time' softkey.
2.
Select desired time from listbox.
3.
Press 'ENT' to confirm.
The release time (= hold time + decay time) is
the time after which the AGC is achieving the
full receiver sensitivity.
It is available for all modulation types except
F3E and F1D. When changing the modulation
mode, the default release times are loaded
once again. So, for global changes, better use
the Fixed Frequency Configuration menu to
change the defaults directly.
Possible values:
25 ms - 150 ms - 500 ms - 1000 ms - 3000 ms
- 5000 ms - 9000 ms
Содержание M3SR 4100 Series
Страница 15: ...M3SR Series 4100 Documentation Overview xiv Operating Manual 6175 4760 02 01...
Страница 48: ...M3SR Series 4100 Index 34 Operating Manual 6175 4760 02 01 ZF4401 mod 02 2 10...
Страница 70: ...M3SR Series 4100 Radio Control 1 22 Operating Manual 6175 4760 02 01...
Страница 116: ...M3SR Series 4100 Example Configuration 2 46 Operating Manual 6175 4760 02 01...
Страница 336: ...M3SR Series 4100 Priority Channel 3 220 Operating Manual 6175 4760 02 01...
Страница 546: ...M3SR Series 4100 Further Settings are Relevant for SECOM H Operation 4 210 Operating Manual 6175 4760 02 01...
Страница 696: ...M3SR Series 4100 Remote Control 8 4 Operating Manual 6175 4760 02 01...
Страница 697: ...Operating Manual 6175 4760 02 01 9 1 M3SR Series 4100 Drawings 9 Drawings...
Страница 706: ...M3SR Series 4100 Drawings 9 10 Operating Manual 6175 4760 02 01...