Operating Manual 6175.4760.02 – 01
3.101
M3SR Series 4100
Control Unit Maintenance
Open a listbox and select
with the knob the Receive
Level Scale to be used for
the Receive Level Bar-
graph.
Press 'ENT' to confirm.
The receive level bargraph
is displayed in the Home
menu and in the operational
domain menus when the ra-
dio is receiving (Rx). It
shows the strength of the
receive level in dBµV.
Default: 120 dBµV
20 dBµV
50 dBµV
120 dBµV
Open a list box and select with the knob the Signal-to-
Noise (SN) Scale. In the reception mode for digital trans-
mission methods there is a signal-to-noise ratio (SNR) bar
displayed in the central area of the operation menu and
through this softkey the operator can change the indicating
range of it. If the SN Scale has the value 28 dB, the bar in-
dicating range goes from -5 dB to +23 dB. If the SN Scale
has the value 70 dB, the bar indicating range goes from -
20 dB to +50 dB.
The SNR bar is provided for the following digital transmis-
sion methods: ALE, HFM and SDV.
Open a listbox and use the
knob to select the connec-
tion quality between control
unit and radio.
Press 'ENT' to confirm.
Default: Fast
Fast
Medium
Slow
Very Slow
The connection quality is dependent on the LAN the
radio and the control unit are connected to. In case of
a slow connection due to slow LAN connection select
'Slow' or 'Very Slow'. Otherwise select 'Medium' or
'Fast'.
Navigate to the Control Unit Inventory menu (see ”Control
Unit Inventory (4021)” on p. 3.106).
Navigate to the Control Unit Error List menu (see ”Control
Unit Error List (4011)” on p. 3.103).
Softkey
Description
Possible Values
Содержание M3SR 4100 Series
Страница 15: ...M3SR Series 4100 Documentation Overview xiv Operating Manual 6175 4760 02 01...
Страница 48: ...M3SR Series 4100 Index 34 Operating Manual 6175 4760 02 01 ZF4401 mod 02 2 10...
Страница 70: ...M3SR Series 4100 Radio Control 1 22 Operating Manual 6175 4760 02 01...
Страница 116: ...M3SR Series 4100 Example Configuration 2 46 Operating Manual 6175 4760 02 01...
Страница 336: ...M3SR Series 4100 Priority Channel 3 220 Operating Manual 6175 4760 02 01...
Страница 546: ...M3SR Series 4100 Further Settings are Relevant for SECOM H Operation 4 210 Operating Manual 6175 4760 02 01...
Страница 696: ...M3SR Series 4100 Remote Control 8 4 Operating Manual 6175 4760 02 01...
Страница 697: ...Operating Manual 6175 4760 02 01 9 1 M3SR Series 4100 Drawings 9 Drawings...
Страница 706: ...M3SR Series 4100 Drawings 9 10 Operating Manual 6175 4760 02 01...