at the top as a safety
margin in dynamic
positioning
calculations.
rf_lift_safe_down
Fraction of the total
stroke that is reserved
at the bottom as a
safety margin in
dynamic positioning
calculations.
Default: 0.05
rf_lift_alt_boost
Preferred lifting column
position as a fractional
number between the
lowest and highest
possible positions.
Default: 1 (keep as high as
possible)
rf_lift_optimistic
Dynamic Positioning
will try to re-use the
last used lifting column
position whenever
possible
Default: True (re-use current lifting
column position whenever
possible)
9.4.6 - Other/Special
Name
Description
Reference
rf_goto_wait
Go through the default
waiting position before
picking the next box
Default: False
rf_release_strategy
Bitmask that selects
one or more waypoints
to be removed from the
return path
Bit 0: remove box free
Bit 1: remove target
position
Bit 2: use vertical exit
path
Bit 3: remove approach
point
Bit 4: remove
everything after
smart-exit point
Default: 7
(remove box free, remove target
position, use vertical exit)
rf_custom_path
Skip path planning
completely (use in
Default: False
Version 2.9.1
© Rocketfarm AS 2021. All rights reserved.
111