MTR 221 ACS - MTR 221 ACS DHHS
MANUALE ISTRUZIONI / INSTRUCTION MANUAL
O
PTIONAL
I
TEMS
167
Model R 221 ACS - R 221 ACS DHHS
MT
R
2
21
ACS
-
MTR
2
21
AC
S DHH
S - Optio
nal Ite
m
s
Calibration
The two switches on the sensor front serve as reference
Sensor Calibration
• Rotate the Light/Dark switch to LIGHT ON to activate the sensor when the object is in
measuring range.
• Set the object at the required detection distance and adjustment the sensitivity switch by
increasing the potentiometer until the orange LED light is lit.
• Remove the object and set sensitivity half-way between the detected point and maximum
potentiometer value.
W
ARNING
M
AKE
SURE
THAT
THE
PROXIMITY
SENSOR
IS
WORKING
PROPERLY
.
A
N
IMPROPER
USE
OF
THE
PROXIMITY
SENSOR
MIGHT
CAUSE
HARM
TO
THE
PATIENT
.
W
ARNING
R
ALCO
REFUSES
TO
ACCEPT
ANY
LIABILITY
FOR
DAMAGES
IN
THE
EVENT
OF
FAILED
OR
IMPROPER
OPERATION
OF
THE
DEVICE
.
Содержание R 221 ACS DHHS Series
Страница 7: ...MTR 221 ACS MTR 221 ACS DHHS MTR 221 ACS MTR 221 ACS DHHS 3...
Страница 8: ...MTR 221 ACS MTR 221 ACS DHHS MTR 221 ACS MTR 221 ACS DHHS 4...
Страница 245: ...info_cl fm...