Performance Monitoring
WinLink User and Installation Guide
Version 1.750
6-112
Viewing Performance Reports
The Performance Monitor Report displays performance views of each
of the interfaces
3
:
Figure
6-9: Performance Monitoring Report window
Several performance data occurrences are collected for each of the
interfaces (ES, SES, and UAS), as well as Specific data per Interface
type (e.g., TX and RX bytes for Ethernet). For the Air Interface, user
defined thresholds data are collected. Refer to
Table
6-3
and
Table
6-4, Performance Monitoring Report Toolbar.
Data is collected and selectively displayed based on three time
intervals as selected by the
Interval
radio buttons:
•
Current (t=0)
•
15 minutes Intervals
•
Daily.
UAS
– This parameter counts the time the air link was not providing
any service. There are several potential reasons for this situation; one
of the sites has a power failure, high interference, maintenance
operation, etc.
3
Ethernet performance is not collected in PoE systems.